Product Information

G2UM300VL20

G2UM300VL20 electronic component of Tele

Datasheet
RELAY, VOLTAGE SENSING, DPDT, 240V

Manufacturer: Tele
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 99.7101 ea
Line Total: USD 99.71

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Tue. 21 May to Mon. 27 May

MOQ : 1
Multiples : 1
1 : USD 99.7101
5 : USD 96.3018
10 : USD 91.5642

     
Manufacturer
Product Category
Product
Type
Contact Form
Contact Current Rating
Coil Type
Coil Voltage
Coil Current
Mounting Style
Supply Voltage Max
Power Consumption
Contact Voltage Vdc
Relay Terminals
Relay Mounting
Approvals Standards
Svhc
Contact Voltage Ac Max
Delay Time Range
External Depth
External Length / Height
External Width
Nom Input Voltage
Timer Functions
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
V2ZI10 12-240V AC/DC electronic component of Tele V2ZI10 12-240V AC/DC

TIME RELAY, ASYMMETRIC FLASHER, 12-240V
Stock : 0

G2UM300VL20 24-240VAC/DC electronic component of Tele G2UM300VL20 24-240VAC/DC

RELAY, VOLTAGE SENSING, DPDT, 240V
Stock : 0

G2ZI20 electronic component of Tele G2ZI20

TIMER, TWO-TIME, MULTIFUNCTION-6
Stock : 0

G2ZIF20 24-240V electronic component of Tele G2ZIF20 24-240V

TIMER, MULTIFUNCTION-7, 2 CO
Stock : 0

OVL1 24VAC/DC electronic component of Tele OVL1 24VAC/DC

RELAY, SPDT, 28VAC, 8A
Stock : 0

R20 electronic component of Tele R20

POTENTIOMETER, REMOTE, 1-10 SCALE
Stock : 0

V2ZM10 12-240V AC/DC electronic component of Tele V2ZM10 12-240V AC/DC

TIME RELAY, MULTIFUNCTION, 12-240V AC/DC
Stock : 0

TVC11 electronic component of Tele TVC11

BASE FOR SERIES FRONT; Socket Mounting:-; Socket Terminals:-; No. of Pins:-; Current Rating:-; Voltage Rating:-; Product Range:-; SVHC:No SVHC (27-Jun-2018); Accessory Type:Mounting Base
Stock : 0

TST1 15 electronic component of Tele TST1 15

THYRISTOR CONTROL UNIT
Stock : 0

Image Description
1617761-2 electronic component of TE Connectivity 1617761-2

Industrial Relays FCB-405-BZ3
Stock : 0

EMR4-I15-1-A electronic component of Eaton EMR4-I15-1-A

Module: current monitoring relay; AC current, DC current; DIN
Stock : 0

62.82.9.024.0000 electronic component of Finder 62.82.9.024.0000

Relay: electromagnetic; DPDT; 24VDC; 16A; industrial; Series:62.82
Stock : 116

6-1393090-4 electronic component of TE Connectivity 6-1393090-4

Relay: electromagnetic; DPDT; Ucoil:24VAC; 10A/250VAC; 10A/30VDC
Stock : 376

60.13.4.102.0040 electronic component of Finder 60.13.4.102.0040

Relay: electromagnetic; 3PDT; 10A/250VAC; 20A; max400VAC; PIN:11
Stock : 2

60.12.9.110.0040 electronic component of Finder 60.12.9.110.0040

Relay: electromagnetic; DPDT; Ucoil:110VDC; 10A/250VAC; 10A/30VDC
Stock : 6

60.12.9.048.0040 electronic component of Finder 60.12.9.048.0040

Relay: electromagnetic; DPDT; Ucoil:48VDC; 10A/250VAC; 10A/30VDC
Stock : 0

60.12.8.110.0040 electronic component of Finder 60.12.8.110.0040

Relay: electromagnetic; DPDT; Ucoil:110VAC; 10A/250VAC; 10A/30VDC
Stock : 0

60.12.8.048.0040 electronic component of Finder 60.12.8.048.0040

Relay: electromagnetic; DPDT; Ucoil:48VAC; 10A/250VAC; 10A/30VDC
Stock : 0

586 108111 electronic component of White-Rodgers 586 108111

Contactors - Electromechanical SPNO 15VDC
Stock : 0

G2UM300VL20 AC/DC voltage monitoring in 1-phase mains 24-240V Monitoring relays - GAMMA series Multifunction 16.6 to 400Hz Fault latch Zoom voltage 24 to 240V AC/DC 2 change-over contacts Width 22.5mm Industrial design Technical data 1. Functions 6. Output circuit AC/DC voltage monitoring in 1-phase mains with adjustable 2 potential free change-over contacts thresholds, timing for start-up suppression and tripping delay Rated voltage: 250V AC separately adjustable and the following functions (selectable by means Switching capacity: 750VA (3A / 250V AC) of rotary switch) If the distance between the devices is less than 5mm OVER Overvoltage monitoring Switching capacity: 1250VA (5A / 250V AC) OVER+LATCH Overvoltage monitoring with fault latch If the distance between the devices is greater than 5mm UNDER Undervoltage monitoring Fusing: 5A fast acting 6 UNDER+LATCH Undervoltage monitoring with fault latch Mechanical life: 20 x 10 operations 5 WIN Monitoring the window between Min and Max Electrical life: 2 x 10 operations at 1000VA resistive load WIN+LATCH Monitoring the window between Switching frequency: max. 60/min at 100VA resistive load Min and Max with fault latch max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1) 2. Time ranges Overvoltage category: III (in accordance with IEC 60664-1) Adjustment range Rated surge voltage: 4kV Start-up suppression time: 0s 10s Tripping delay: 0.1s 10s 7. Measuring circuit Fusing: max. 20A (in accordance with UL 508) 3. Indicators Measured variable: DC or AC Sinus (16.6 to 400Hz) Green LED ON: indication of supply voltage Input: Green LED flashes: indication of start-up suppression time 30V AC/DC terminals E-F1(+) Yellow LED ON/OFF: indication of relay output 60V AC/DC terminals E-F2(+) Red LED ON/OFF: indication of failure of the corresponding 300V AC/DC terminals E-F3(+) threshold Overload capacity: Red LED flashes: indication of tripping delay 30V AC/DC 100Veff of the corresponding threshold 60V AC/DC 150Veff 300V AC/DC 440Veff 4. Mechanical design Input resistance: Self-extinguishing plastic housing, IP rating IP40 30V AC/DC 47k Mounted on DIN-Rail TS 35 according to EN 60715 60V AC/DC 100k Mounting position: any 300V AC/DC 470k Shockproof terminal connection according to VBG 4 (PZ1 required), Switching threshold IP rating IP20 Max: 10% to 100% of U N Tightening torque: max. 1Nm Min: 5% to 95% of U N Terminal capacity: Overvoltage category: III (in accordance with IEC 60664-1) 1 x 0.5 to 2.5mm with/without multicore cable end Rated surge voltage: 4kV 1 x 4mm without multicore cable end 2 x 0.5 to 1.5mm with/without multicore cable end 8. Accuracy 2 x 2.5mm flexible without multicore cable end Base accuracy: 5% (of maximum scale value) Frequency response: -10% to +5% (at 16.6 to 400Hz) 5. Input circuit Adjustment accuracy: 5% (of maximum scale value) Supply voltage: Repetition accuracy: 2% 24 to 240V AC/DC terminals A1-A2 (galvanically separated) Voltage influence: - Tolerance: Temperature influence: 0.05% / C 24 to 240V DC -20% to +25% 24 to 240V AC -15% to +10% 9. Ambient conditions Rated frequency: Ambient temperature: -25 to +55C 24 to 240V AC 48 to 400Hz (in accordance with IEC 60068-1) 48 to 240V AC 16 to 48Hz -25 to +40C (in accordance with UL 508) Rated consumption: 4.5VA (1W) Storage temperature: -25 to +70C Duration of operation: 100% Transport temperature: -25 to +70C Reset time: 500ms Relative humidity: 15% to 85% Wave form for AC: Sinus (in accordance with IEC 60721-3-3 class 3K3) Residual ripple for DC: 10% Pollution degree: 3 (in accordance with IEC 60664-1) Drop-out voltage: >15% of the supply voltage Vibration resistance: 10 to 55Hz 0.35mm Overvoltage category: III (in accordance with IEC 60661-1) (in accordance with IEC 60068-2-6) Rated surge voltage: 4kV Shock resistance: 15g 11ms (in accordance with IEC 60068-2-27) www.tele-online.comG2UM300VL20 24-240V Window function (WIN, WIN+LATCH) Functions The output relays switch into on-position (yellow LED illuminated) when the measured voltage exceeds the value adjusted at the MIN-regulator. When the supply voltage U is applied, the output relays switch into When the measured voltage exceeds the value adjusted at the MAX- on-position (yellow LED illuminated) and the set interval of the start-up regulator, the set interval of the tripping delay (DELAY) begins (red LED suppression (START) begins (green LED U flashes). Changes of the MAX flashes). After the interval has expired (red LED MAX illuminated), measured voltage during this period do not affect the state of the output the output relays switch into off-position (yellow LED not illuminated). relay. After the interval has expired the green LED is illuminated steadily. The output relays again switch into on-position (yellow LED illuminated) For all the functions the LEDs MIN and MAX are flashing alternating, when the measured voltage falls below the value adjusted at the MAX- when the minimum value for the measured voltage was chosen to be regulator (red LED MAX not illuminated). When the measured voltage greater than the maximum value. falls below the value adjusted at the MIN-regulator, the set interval of the tripping delay (DELAY) begins again (red LED MIN flashes). After the Overvoltage monitoring (OVER, OVER+LATCH) interval has expired (red LED MIN illuminated), the output relays switch When the measured voltage exceeds the value adjusted at the into off-position (yellow LED not illuminated). MAX-regulator, the set interval of the tripping delay (DELAY) begins (red LED MAX flashes). After the interval has expired (red LED MAX illuminated), the output relays switch into off-position (yellow LED not illuminated). The output relays again switch into on-position (yellow LED illuminated), when the measured voltage falls below the value adjusted at the MIN-regulator (red LED MAX not illuminated). If the fault latch is activated (OVER+LATCH) and the measured voltage remains above the MAX-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the measured voltage falls below the value adjusted at the MIN-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring cycle begins with the set interval of the start-up suppression (START). If the fault latch is activated (WIN+LATCH) and the measured voltage remains below the MIN-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the measured voltage exceeds the value adjusted at the MIN-regulator. If the measured voltage remains above the MAX-value longer than the set interval of the tripping delay, the output relays remain in the off-position even if the measured voltage falls below the value adjusted at the MAX-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring cycle begins with the set interval of the start-up suppression (START). Undervoltage monitoring (UNDER, UNDER+LATCH) When the measured voltage falls below the value adjusted at the MIN-regulator, the set interval of the tripping delay (DELAY) begins (red LED MIN flashes). After the interval has expired (red LED MIN illuminated), the output relays switch into off-position (yellow LED not illuminated). The output relays again switch into on-position (yellow LED illuminated), when the measured voltage exceeds the value adjusted at the MAX-regulator. If the fault latch is activated (UNDER+LATCH) and the measured voltage remains below the MIN-value longer than the set interval of the tripping delay, the output relays remain in the off- position even if the measured voltage exceeds the value adjusted at the MAX-regulator. After resetting the failure (interrupting and re-applying the supply voltage), the output relays switch into on-position and a new measuring cycle begins with the set interval of the start-up suppression (START). www.tele-online.com

Tariff Desc

8536.49.00 TC17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC8909066 RELAYS having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mmx30mmx27mm

8536.49.00 TC9613322 RELAYS low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24mm
(b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8AAC

8536.49 TC8906734 RELAYS having ALL of the following:
(a) one, two or three contacts
(b) maximum continuous contact current rating of NOT less than 15A
(c) maximum contact voltage rating of NOT less than 380V
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC1122469 RELAYS having an operating voltage NOT exceeding 250volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC8534635 RELAYS cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5A (AC or DC);
(b) switching voltage NOT exceeding 250V (AC or DC);
(c) body dimensions NOT exceeding 31mm x36mm x19mm

8536.49 TC8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following:
(a) normally closed main poles;
(b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8538.90.90 08 .. For programmable controllers Other Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted