Ships to you between Thu. 16 May to Mon. 20 May
GV2ME01 Schneider
Ships to you between Fri. 10 May to Thu. 16 May
Motor breaker; 0.12/0.18kW; 230÷690VAC; DIN; IP20; -20÷60°C Stock : 21
Motor breaker; 0.25kW; 230÷690VAC; DIN; Short circ.release:13A Stock : 61
Motor breaker; 0.06kW; 230÷690VAC; DIN; Short circ.release:2.4A Stock : 16
Motor breaker; 0.09kW; 230÷690VAC; DIN; Short circ.release:5A Stock : 10
Motor Drives MAN-START 600VAC 1AMP IEC Stock : 2
Motor breaker; 0.04kW; 230÷690VAC; DIN; Short circ.release:1.5A Stock : 2
Motor breaker; 0.06kW; 230÷690VAC; DIN; Short circ.release:2.4A Stock : 12
Motor breaker; 0.09kW; 230÷690VAC; DIN; Short circ.release:5A Stock : 9
Motor breaker; 0.12/0.18kW; 230÷690VAC; DIN; IP20; -20÷60°C Stock : 16
Motor breaker; 0.25kW; 230÷690VAC; DIN; Short circ.release:13A Stock : 40
Motor breaker; 0.37/0.55kW; 230÷690VAC; DIN; IP20; -20÷60°C Stock : 66
Motor breaker; 0.75kW; 230÷690VAC; DIN; Short circ.release:33.5A Stock : 205
Motor breaker; 1.1/1.5kW; 230÷690VAC; DIN; IP20; -20÷60°C Stock : 42
Motor breaker; 5.5kW; 230÷690VAC; DIN; Overcurrent release:9÷14A Stock : 53
Motor breaker; 11kW; 230÷690VAC; DIN; Overcurrent release:20÷25A Stock : 38
Motor breaker; 0.04kW; 230÷690VAC; DIN; Short circ.release:1.5A Stock : 6
Motor Drives MAN-START 600VAC 0.25AMP IEC Stock : 10
Motor Drives MAN-START 600VAC 0.63AMP IEC Stock : 12
Product data sheet GV2ME01 Characteristics TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, push buttons, 0.1...0.16 A, screw clamp terminals Product availability: Stock - Normally stocked in distribution facility Main Range TeSys Product name TeSys GV2 Device short name GV2ME Device application Motor Trip unit technology Thermal-magnetic Complementary Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode Clipped on 35 mm symmetrical DIN rail Screwed on panel (with adaptor plate) Operating position Any position Breaking capacity 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 Ics rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Control type Push-button In rated current 0.16 A Thermal protection adjustment range 0.1...0.16 A Magnetic tripping current 1.5 A System Voltage AC 50/60 Hz conforming to IEC 60947-2 Ui rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 Ith conventional free air thermal current 0.16 A conforming to IEC 60947-4-1 Uimp rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Power dissipation per pole 2.5 W Mechanical durability 100000 cycles Electrical durability 100000 cycles AC-3 at 440 V Operating rate 25 cyc/h Rated duty Continuous conforming to IEC 60947-4-1 Connections - terminals Screw clamp terminals 2 cable(s) 0...0.01 in (1...6 mm) solid Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) flexible without cable end Screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) flexible with cable end Tightening torque 15.04 lbf.in (1.7 N.m) on screw clamp terminals Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Suitability for isolation Yes conforming to IEC 60947-1 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Height 3.5 in (89 mm) Width 1.75 in (44.5 mm) Depth 3.08 in (78.2 mm) Product weight 0.57 lb(US) (0.26 kg) Environment Standards VDE 0660 IEC 60947-1 EN 60204 UL 508 NF C 79-130 NF C 63-120 VDE 0113 CSA C22.2 IEC 60947-2 NF C 63-650 IEC 60947-4-1 Product certifications CSA LROS (Lloyds register of shipping) CCC EAC CEBEC RINA GL BV TSE DNV SETI ATEX EZU UL Protective treatment TH IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK04 Ambient air temperature for operation -4...140 F (-20...60 C) Ambient air temperature for storage -40...176 F (-40...80 C) Fire resistance 1760 F (960 C) conforming to IEC 60695-2-1 Operating altitude 6561.68 ft (2000 m) Ordering and shipping details Category 22367 - MANUAL STR PROTECTOR - GV2 Discount Schedule I11 GTIN 00785901211884 Nbr. of units in pkg. 1 Package weight(Lbs) 0.53000000000000003 Returnability Y Country of origin TH Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 0631 - Schneider Electric declaration of conformity Schnei- der Electric declaration of conformity REACh Reference contains SVHC above the threshold - Go to CaP for more details- Go to CaP for more details Product environmental profile Available Product end of life instructions Need no specific recycling operations California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. - - - - - - - More information For more information go to www.p65warnings.ca.gov 2