Ships to you between Fri. 17 May to Tue. 21 May
GV2ME08 Schneider
Ships to you between Mon. 13 May to Fri. 17 May
LED Lighting Fixture Accessories INDICATING BANK ACCESSORIES 100MM Stock : 6
LED Lighting Fixture Accessories REPLACEMENT CAP FOR XVB WIRING BASE Stock : 10
LED Lighting Fixtures Mounting Base f/ XVB Stock : 9
LED Lighting Fixtures FIXING BASE 80MM w/ SUPPORT TUBE Stock : 2
LED Lighting Fixture Accessories INDICATING BANK Stock : 0
LED Lighting Fixtures FIXING BASE 80MM W/ SUPPORT TUBE Stock : 7
LED Lighting Fixture Accessories INDICATING BANK ACCESSORIES 70MM Stock : 13
LED Lighting Fixture Accessories INDICATING BANK ASSRY 14MM+OPTIONS Stock : 5
LED Lighting Fixture Accessories INDICATING BANK ACCESSORIES 400MM Stock : 1
Contactors - Electromechanical 2PNO 24VAC Stock : 1
Contactor:4-pole; NO x4; 24VDC; 7A; DIN, on panel; B7D; -20÷55°C Stock : 4
Contactor Insulation Barrier Stock : 1
Contactors - Electromechanical RELAY CONTACTOR 30A 120VAC QC Stock : 151
Undervoltage relase; 230/240VAC; side Stock : 1
Auxiliary contacts; Auxiliary contacts: NC x2; front Stock : 1
Contactor:1-pole installation; NC; 24VAC; 24VDC; 20A; DIN; IKD Stock : 0
Contactor:3-pole installation; NO x3; 24VAC; 24VDC; 25A; DIN; IKD Stock : 0
Quick connect surge suppressor - For BG series mini contactor - 225 VDC (Diode). Stock : 0
Contactors - Electromechanical MINI CONTACTOR, 9A/380/440V Stock : 1
Product data sheet GV2ME08 Characteristics TeSys GV2 Manual Starter and Protector, thermal magnetic circuit protector, push buttons, 2.5 to 4 A, screw clamp Product availability: Stock - Normally stocked in distribution facility Main Range TeSys Product name TeSys GV2 Device short name GV2ME Device application Motor Trip unit technology Thermal-magnetic Complementary Poles description 3P Network type AC Utilisation category AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 Network frequency 50/60 Hz conforming to IEC 60947-4-1 Fixing mode Clipped on 35 mm symmetrical DIN rail Screwed on panel (with adaptor plate) Operating position Any position Motor power kW 3 kWat 690 V AC 50/60 Hz 1.1 kW at 400/415 V AC 50/60 Hz 1.5 kW at 400/415 V AC 50/60 Hz 1.5 kW at 500 V AC 50/60 Hz 2.2 kW at 500 V AC 50/60 Hz 2.2 kW at 690 V AC 50/60 Hz Breaking capacity 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 Ics rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 Control type Push-button In rated current 4 A Thermal protection adjustment range 2.5...4 A Magnetic tripping current 51 A System Voltage AC 50/60 Hz conforming to IEC 60947-2 Ui rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2 Ith conventional free air thermal current 4 A conforming to IEC 60947-4-1 Uimp rated impulse withstand voltage 6 kV conforming to IEC 60947-2 Power dissipation per pole 2.5 W Mechanical durability 100000 cycles Electrical durability 100000 cycles AC-3 at 440 V Operating rate 25 cyc/h Aug 11, 2019 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Rated duty Continuous conforming to IEC 60947-4-1 Connections - terminals Screw clamp terminals 2 cable(s) 0...0.01 in (1...6 mm) solid Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) flexible without cable end Screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) flexible with cable end Tightening torque 15.04 lbf.in (1.7 N.m) on screw clamp terminals Suitability for isolation Yes conforming to IEC 60947-1 Phase failure sensitivity Yes conforming to IEC 60947-4-1 Height 3.5 in (89 mm) Width 1.77 in (45 mm) Depth 3.08 in (78.2 mm) Product weight 0.57 lb(US) (0.26 kg) Environment Standards UL 508 IEC 60947-2 NF C 79-130 CSA C22.2 IEC 60947-4-1 NF C 63-650 VDE 0660 EN 60204 NF C 63-120 VDE 0113 IEC 60947-1 Product certifications SETI GL BV CSA CEBEC TSE CCC UL EZU LROS (Lloyds register of shipping) DNV RINA ATEX EAC Protective treatment TH IP degree of protection IP20 conforming to IEC 60529 IK degree of protection IK04 Ambient air temperature for operation -4...140 F (-20...60 C) Ambient air temperature for storage -40...176 F (-40...80 C) Fire resistance 1760 F (960 C) conforming to IEC 60695-2-1 Operating altitude 6561.68 ft (2000 m) Ordering and shipping details Category 22367 - MANUAL STR PROTECTOR - GV2 Discount Schedule I11 GTIN 00785901211952 Nbr. of units in pkg. 1 Package weight(Lbs) 0.57999999999999996 Returnability Y Country of origin TH 2