Product Information

RWK212-16-KL

RWK212-16-KL electronic component of Schaffner

Datasheet
Power Line Filters 3 Phase Input Line Reactor 500VAC, 16A

Manufacturer: Schaffner
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Obsolete
Availability Price Quantity
0 - Global Stock

MOQ : 1
Multiples : 1

Stock Image

RWK212-16-KL
Schaffner

1 : USD 216.994
5 : USD 223.0862
10 : USD 220.8465
25 : USD 218.6494
N/A

Obsolete
0 - Global Stock

MOQ : 1
Multiples : 1

Stock Image

RWK212-16-KL
Schaffner

1 : USD 161.2772
2 : USD 161.2772
5 : USD 161.2772
10 : USD 161.2772
25 : USD 161.2772
50 : USD 159.0943
100 : USD 148.8689
N/A

Obsolete
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Filter Type
Voltage Rating
Current Rating
Mounting Style
Series
Inductance
Brand
Maximum Operating Temperature
Minimum Operating Temperature
Product Type
Factory Pack Quantity :
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
RWK212-60-KL electronic component of Schaffner RWK212-60-KL

Power Line Filters 3 Phase Input Line Reactor 500VAC, 60A
Stock : 0

RWK-305-4-KL electronic component of Schaffner RWK-305-4-KL

Schaffner Power Line Filters THREE PHASE DVDT REACTOR
Stock : 4

RWK305-60-KL electronic component of Schaffner RWK305-60-KL

Circuit Protection Misc Three Phase Reactor For Efficient Motor Protector
Stock : 0

RWK-305-14-KL electronic component of Schaffner RWK-305-14-KL

Power Line Filters 14A 5.5kW 0.42mH 3phase dv/dt Reactor
Stock : 0

RWK-305- 7.8-KL electronic component of Schaffner RWK-305- 7.8-KL

Power Line Filters 7.8A 3kW 0.754mH 3Phase dv/dt Reactor
Stock : 0

RWK305-24-KL electronic component of Schaffner RWK305-24-KL

Power Line Filters 3 Phase dv/dt Output Reactor 500VAC, 24A
Stock : 0

RWK305-32-KL electronic component of Schaffner RWK305-32-KL

Power Line Filters 3 Phase dv/dt Output Reactor 500VAC, 32A
Stock : 0

RWK305-45-KL electronic component of Schaffner RWK305-45-KL

Power Line Filters 3 Phase dv/dt Output Reactor 500VAC, 45A
Stock : 0

RWK305-10-KL electronic component of Schaffner RWK305-10-KL

Power Line Filters 3 Phase dvdt Output Reactor 500VAC 10A
Stock : 0

RWK212-7-KL electronic component of Schaffner RWK212-7-KL

Power Line Filters 3 Phase Input Line Reactor 500VAC 7A
Stock : 0

Image Description
B84143A0035R107 electronic component of TDK B84143A0035R107

Power Line Filters 35A 300/520V 3-LINE EMC FILTER
Stock : 0

TPM1714BE3MG5K7T04 electronic component of Vicor TPM1714BE3MG5K7T04

Power Line Filters 3 phase 1714 VIA PCB T Grade Short Pins
Stock : 0

TPM1714BE3MG5K7T08 electronic component of Vicor TPM1714BE3MG5K7T08

Power Line Filters 3 phase 1714 VIA PCB T Grade Long Pins
Stock : 1

TPM1714VE3MG5K7C00 electronic component of Vicor TPM1714VE3MG5K7C00

Power Line Filters 3 phase 1714 VIA Chassis C Grade
Stock : 4

TPM1714BE3MG5K7C08 electronic component of Vicor TPM1714BE3MG5K7C08

Power Line Filters 3 phase 1714 VIA PCB C Grade Long Pins
Stock : 2

TPM1714BE3MG5K7C04 electronic component of Vicor TPM1714BE3MG5K7C04

Power Line Filters 3 phase 1714 VIA PCB C Grade Short Pins
Stock : 0

TPM1714VE3MG5K7T00 electronic component of Vicor TPM1714VE3MG5K7T00

Power Line Filters 3 phase 1714 VIA Chassis T Grade
Stock : 3

6SL3054-4AG00-2AA0 electronic component of Siemens 6SL3054-4AG00-2AA0

Memory card; Series: SINAMICS V20; Application: SINAMICS V20
Stock : 0

6SL3210-5BB11-2BV1 electronic component of Siemens 6SL3210-5BB11-2BV1

Inverter; Max motor power:1.1kW; Usup:200÷240VAC; 0÷599Hz; 6A
Stock : 0

6SL3210-5BE13-7CV0 electronic component of Siemens 6SL3210-5BE13-7CV0

Inverter; Max motor power:0.37kW; Out.voltage:3x400VAC; 0÷599Hz
Stock : 1

DATASHEET AC Line Reactors RWK 212 3-phase Line Reactor for Motor Drive & Power Quality Applications Provision of 4% impedance Approvals Reduction of mains harmonics Reduction of commutation notches Protection of motor drive electronics Limitation of inrush currents UL 508C up to 400 A. For use with AC or DC drives Improvement of true power factor (power conversion equipment) only Features and benefits Ensure reliability, performance and a long service life of electrical consumers Reduction of mains harmonics and commutation Performance indicators notches 1 Help to meet international power quality standards such as IEEE-519 or EN 61000-3-2 Protection of motor drive electronics and dc link capacitors against mains transients Reduction of inrush and peak currents Reduction of conducted LF emission Improvement of conducted LF immunity Technical specifications Prevention from nuisance tripping caused by power line voltage spikes Maximum continuous operating voltage 3 x 500/288 VAC Improvement of true power factor EN 61558-2-20 (VDE 0570-2-20), UL 508C, CSA C22.2 Design corresponding to NO.14 Operating frequency DC to 60 Hz Typical applications 4% 400 VAC, 50 Hz & rated current Impedance Motor drives and various adjustable speed drive Typical harmonics reduction See table on next page systems, such as: High potential test voltage P > E 3000 VAC for 3 sec P > P 3000 VAC for 3 sec Elevators Insulation class T40/N (200C) for 400 A types Robots T40/F (155C) for 500 A types Machinery T40/H (180C) for 1500 A types Process automation equipment Protection category IP 00 (KL types according to VBG 4) Rated currents 4 to 1500 A 40C 2 x rated current at switch on for 30 seconds Overload capability Typical electrical schematic 1.5 x rated current for 1 minute, once per hour Flammability corresponding to UL 94 V-2 or better Temperature range (operation and storage) -25C to +100C (25/100/21) >500,000 hours MTBF 40C/400 V (Mil-HB-217F)2 Reactors Schaffner Group Datasheets 13 Feb 2019 Reactor selection table Reactor Rated current Typical drive Nominal Typical Input/Output Weight Earthing bolt 40C power rating* inductance power loss** connections Total A kW mH W kg RWK 212-4-KL 4 1.5 7.3 23 KL 2.1 AMP 6,3 x 0,8 RWK 212-7-KL 7 3 4.2 36 KL 2.5 M4 RWK 212-11-KL 11 4 2.6 37 KL 2.5 M4 RWK 212-16-KL 16 7.5 1.8 59 KL 3.9 M5 RWK 212-21-KL 21 11 1.4 66 KL 5.4 M5 RWK 212-29-KL 29 15 1 69 KL 5.4 M5 RWK 212-35-KL 35 18.5 0.84 70 KL 5.9 M5 RWK 212-46-KL 46 22 0.64 99 KL 11 M8 RWK 212-60-KL 60 30 0.49 138 KL 15 M8 RWK 212-75-KL 75 37 0.39 133 KL 15 M8 RWK 212-95-KL 95 45 0.3 166 KL 22 M10 RWK 212-124-KS 124 55 0.23 172 KS 25 M10 RWK 212-156-KS 156 75 0.19 249 KS 25 M10 RWK 212-182-KS 182 90 0.16 245 KS 32 M10 RWK 212-230-KS 230 110/132 0.13 301 KS 35 M10 RWK 212-280-KS 280 160 0.1 335 KS 41 M10 RWK 212-330-KS 330 160 0.09 386 KS 56 M10 RWK 212-400-S 400 200 0.073 692 S 57 M10 RWK 212-500-S 500 250 0.058 761 S 67 M10 RWK 212-600-S 600 315 0.049 825 S 76 M10 RWK 212-680-S 680 355 0.043 876 S 80 M10 RWK 212-790-S 790 400 0.037 956 S 90 M10 RWK 212-910-S 910 450 0.032 1022 S 107 M10 RWK 212-1100-S 1100 630 0.026 1036 S 135 M10 RWK 212-1310-S 1310 725 0.023 1050 S 100 M10 RWK 212-1500-S 1500 830 0.020 1000 S 225 M10 Customized line reactors with different electrical and mechanical specifications are available on request. * Calculated at rated current, 400 VAC and cos phi=0.8. The exact value depends upon the efficiency of the drive, the motor and the entire application. ** Power loss at 25C/50 Hz, considering a typical harmonic spectrum of a motor drive with B6U rectifier bridge. Harmonics reduction Line reactors are a cost-effective way for the limitation of mains harmonics. The harmonics reduction capability is related to the reactor impedance. A higher impedance translates directly into lower harmonic currents, but of course also into a larger component with a higher voltage drop and vice versa. 4% impedance reactors like RWK 212 provide an excellent cost/benefit ratio and are particularly beneficiary in the most diverse motor drive applications. The table below shows various reactor impedance values and their calculated effect in terms of harmonics reduction. Harmonic number/Input impedance (uk) vs. remaining harmonics % 0.5% 1% 2% 3% 4% 5% 6% 7% 8% 9% 10% 5th 80 60 46 40 34 32 30 28 26 24 23 7th 60 37 22 16 13 12 11 10 9 8.3 7.5 11th 18 12 9 7.3 6.3 5.8 5.2 5 4.3 4.2 4 13th 10 7.5 5.8 4.9 4.2 3.9 3.6 3.3 3.15 3 2.8 17th 7.3 5.2 3.6 3 2.4 2.2 2.1 0.9 0.7 0.5 0.4 19th 6 4.2 2.8 2.2 2 0.8 0.7 0.4 0.3 0.25 0.2 %THID 102.5 72.2 52.3 44.13 37.31 34.96 32.65 30.35 28.04 25.92 24.68 Reading example: a 4% impedance reactor typically reduces the THID to ~37% of the fundamental.

Tariff Desc

8543.70.00 - ELECTRICAL MACHINES AND APPARATUS, HAVING INDIVIDUAL FUNCTIONS, NOT SPECIFIED OR INCLUDED ELSEWHERE IN THIS CHAPTER: Other machines and apparatus Free
91 .. Other
SCHAFFNER EMC
Schaffner EMC Inc
Schaffner EMC Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted