Product Information

ESP SL15X/I

ESP SL15X/I electronic component of Furse

Datasheet
SURGE PROTECTOR, 0.75A

Manufacturer: Furse
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 267.2288 ea
Line Total: USD 267.23

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Mon. 13 May to Fri. 17 May

MOQ : 1
Multiples : 1
1 : USD 300.4761

     
Manufacturer
Product Category
Brand
No. Of Poles
Peak Surge Current
Continuing Operating Voltage Max
Suppressor Mounting
Product Range
Svhc
Output Current
Response Time
Suppressor Type
Voltage Rating
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
WBX4 electronic component of Furse WBX4

ENCLOSURE, POLYCARBONATE, TRANSPARENT
Stock : 0

ESP 240-16A/BX electronic component of Furse ESP 240-16A/BX

SURGE PROTECTOR, 16A
Stock : 0

ESP240-5A electronic component of Furse ESP240-5A

SURGE PROTECTOR, LOW CURRENT, 240V
Stock : 0

ESP 240-5A/BX electronic component of Furse ESP 240-5A/BX

SURGE PROTECTOR, 5A
Stock : 0

ESP415M1R electronic component of Furse ESP415M1R

SURGE PROTECTOR, 1A
Stock : 0

ESP CAT-6/POE electronic component of Furse ESP CAT-6/POE

SURGE PROTECTOR, 0.4A
Stock : 0

ESP 06D electronic component of Furse ESP 06D

SURGE PROTECTOR, 2 WIRE, 6V
Stock : 0

ESP 30Q electronic component of Furse ESP 30Q

SURGE PROTECTOR, 0.75A
Stock : 0

ESP 415 D1 electronic component of Furse ESP 415 D1

SURGE PROTECTOR, 1A
Stock : 0

ESP RF 111A11 electronic component of Furse ESP RF 111A11

SURGE PROTECTOR, 2.7GHZ
Stock : 0

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

NEW ESP SL X Series Application Use these protectors in hazardous environments where installation space is at a premium and large numbers of lines require protection (e.g. process control, 4-20 mA loops, fire and gas detectors and shut-down systems). Suitable for high speed digital communication equipment or systems with long signal lines. See Furse Application Note AN013. Installation Connect in series with the data communication or signal line Combined Category D, C, B tested protector (to BS EN 61643) either near where it enters or suitable for twisted pair signalling applications within hazardous leaves the building or close to environments (ATEX/IECEx approved). Available for working the equipment being protected voltages of up to 15 and 30 Volts. For use at boundaries up to LPZ 0 B (e.g. within its control panel). to protect against flashover through to LPZ 3 to protect sensitive Either way, it must be very close electronic equipment. to the systems earth star point. Install protectors either within an existing cabinet/cubicle or in Features and benefits a separate enclosure. Approved for use in hazardous environments for the protection of Intrinsically Safe circuits (Classification: II 2(1)G, Ex ia (ia Ga) IIC T4 Gb) CLEAN LINE Lightning Barrier Nominal voltage 30V Max working voltage, Uc 36.7V Very low let-through voltage (enhanced protection to BS EN 62305) II 2 (1) G IECEx SIR 10.00 30X Ex ia ia Ga IIC T4 Gb Sira 10 ATEX2063X Li = 0H, Ci = 0H Pi = 1.3W (-40C < Ta < 40C) Pi = 1.2W (-40C < Ta < 60C) Pi = 1W (-40C < Ta < 80C) WARNING Electrostatic Hazard between all lines - Full Mode protection Clean ONLY with a damp cloth 1 3 Furse Wilford Road, 0518 Nottingham, NG2 1EB, UK S S Full mode design capable of handling partial lightning currents as 2 4 well as allowing continual operation of protected equipment Repeated protection in lightning intense environments Ultra slim 7 mm width ideal for compact protection of large numbers From line To equipment of lines (e.g. process control installations) Earth Optional LED status indication versions available for low current DC power applications - add L suffix to part number - e.g. ESP SL30XL Accessories Negligible self-capacitance and self-inductance offering minimal Replacement modules interference when protecting Intrinsically Safe circuits ESP SL15X/M, ESP30X/M Two stage removable protection module with simple quick release Standard module replacement for mechanism allowing partial removal for easy line commissioning and 15 and 30 V protectors respectively maintenance as well as full removal for protection replacement ESP SL15XL/M, ESP30XL/M Very low (1 ) in-line resistance allows resistance critical applications LED module replacement for 15 (e.g. alarm loops) to be protected and 30 V protectors respectively High (750 mA) maximum running current ESP SLX/B High bandwidth enables higher frequency (high traffic or bit rate) Base replacement (common for data communications standard and LED modules) Screen terminal enables easy connection of cable screen to earth ESP SLX/I/B Base replacement with isolated Suitable for earthed or isolated screen systems - add /I suffix to part screen from earth number for versions that require isolated screens - e.g. ESP SL30X/I For suitable enclosures for the Built-in innovative DIN rail foot with locking feature for simple ESP SL X Series, please contact us. positioning and clip-on mounting to top hat DIN rails 2 4 mm terminals allow for larger cross section wiring, stranded wires terminated with ferrules or fitting two wires into a single terminal Convenient earthing through DIN foot and/or earth terminal Approval references for ESP SL X Series: IECEx SIR 10.0030X, Sira 10ATEX2063X Furse, Wilford Road, Nottingham, NG2 1EB Tel: +44 (0)115 964 3700 Email: enquiry furse.com Web: www.furse.com Clean i L neNEW ESP SL X Series Technical specification NEW NEW Electrical specification ESP SL15X ESP SL30X 1 Nominal voltage 15 V 30 V 2 Maximum working voltage Uc 16.7 V 36.7 V Current rating (signal) 750 mA In-line resistance (per line 10%) 1.0 Bandwidth (-3 dB 50 system) 45 MHz 45 MHz Intrinsically Safe specification ESP SL15X ESP SL30X Maximum voltage U 30 V i Maximum power P i - per -40 C < Ta < 40 C 1.3 W - per -40 C < Ta < 60 C 1.2 W - per -40 C < Ta < 80 C 1.0 W Capacitance C 0 F i Inductance L 0 H i Certificate number IECEx SIR 10.0030X, Sira 10ATEX2063X Classification II 2 (1) G, Ex ia (ia Ga) IIC T4 Gb Transient specification ESP SL15X ESP SL30X 3 Let-through voltage (all conductors) Up C2 test 4 kV 1.2/50 s, 2 kA 8/20 s to 38.4 V 63.0 V BS EN/EN/IEC 61643-21 C1 test 1 kV, 1.2/50 s, 0.5 kA 8/20 s to 29.4 V 51.3 V BS EN/EN/IEC 61643-21 B2 test 4 kV 10/700 s to BS EN/EN/IEC 61643-21 26.8 V 45.4 V 4 5 kV, 10/700 s 27.5 V 46.3 V Maximum surge current D1 test 10/350 s to - per signal wire 1.25 kA BS EN/EN/IEC 61643-21 - per pair 2.5 kA 8/20 s to ITU-T K.45:2003, - per signal wire 10 kA IEEE C62.41.2:2002 - per pair 20 kA Mechanical specification ESP SL15X ESP SL30X Temperature range -40 to +80 C Connection type Screw terminal 2 Conductor size (stranded) 4 mm 2 Earth connection Via DIN rail or 4 mm earth terminal Case material FR polycarbonate UL94 V-0 Weight - unit 0.08 kg Weight - packaged (per 10) 0.85 kg Dimensions 1 Nominal voltage (DC or AC peak) measured at < 10 A. 2 Maximum working voltage (DC or AC peak) measured at < 1 mA leakage. 3 The maximum transient voltage let-through of the protector throughout the test (10%), line to line & line to earth, both polarities. Response time < 10 ns. 4 Test to IEC 61000-4-5:2006, ITU-T (formerly CCITT) K.20, 104.6 mm K.21 and K.45, Telcordia GR-1089-CORE, Issue 2:2002, ANSI TIA/EIA/IS-968-A:2002 (formerly FCC Part 68). 106.5 mm 2S 1 1SE2 7 mm Use the standard ESP SL Slim Line Series for non-hazardous areas. The ESP SL Series is also available for protection of 3-wire, RS 485, RTD & telecommunication applications (ESP SL/3W, ESP SL RS485, ESP SL RTD & ESP SL TN). Furse, Wilford Road, Nottingham, NG2 1EB Tel: +44 (0)115 964 3700 Email: enquiry furse.com Web: www.furse.com

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted