Product Information

ECM140 COVER KIT

ECM140 COVER KIT electronic component of XP Power

Datasheet
Switching Power Supplies COVER, ECM140

Manufacturer: XP Power
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 30.8395 ea
Line Total: USD 30.84

9 - Global Stock
Ships to you between
Thu. 09 May to Mon. 13 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
9 - Global Stock


Ships to you between Thu. 09 May to Mon. 13 May

MOQ : 1
Multiples : 1
1 : USD 34.0756
5 : USD 33.0493
10 : USD 32.035
25 : USD 30.6705
120 : USD 28.6177

     
Manufacturer
Product Category
Brand
For Use With
Accessory Type
Svhc
Body Material
Enclosure Material
External Depth
External Height
External Width
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
ECM40/60DT LOOM KIT electronic component of XP Power ECM40/60DT LOOM KIT

LOOM KIT, 3 OUTPUT
Stock : 0

ECM40/60 COVER electronic component of XP Power ECM40/60 COVER

Switching Power Supplies Cover for ECM40/60/65/100
Stock : 725

ECM140US24 electronic component of XP Power ECM140US24

Switching Power Supplies POWER SUPPLY, 140WATT, OPEN FRAME
Stock : 134

ECM40-60 CONKIT electronic component of XP Power ECM40-60 CONKIT

CONNECTOR KIT, ECM40-60
Stock : 0

ECM140US15 electronic component of XP Power ECM140US15

Switching Power Supplies POWER SUPPLY, 140WATT, OPEN FRAME
Stock : 51

ECM140US12 electronic component of XP Power ECM140US12

Switching Power Supplies POWER SUPPLY, 140WATT, OPEN FRAME
Stock : 96

ECM140US18 electronic component of XP Power ECM140US18

Switching Power Supplies POWER SUPPLY, 140WATT, OPEN FRAME
Stock : 0

ECM140US48 electronic component of XP Power ECM140US48

Switching Power Supplies POWER SUPPLY, 140WATT, OPEN FRAME
Stock : 0

ECM140US28 electronic component of XP Power ECM140US28

Switching Power Supplies POWER SUPPLY, 140WATT, OPEN FRAME
Stock : 0

ECM40/60DT LOOM electronic component of XP Power ECM40/60DT LOOM

CABLE HARNESS, AC/DC POWER SUPPLY; For U; CABLE HARNESS, AC/DC POWER SUPPLY; For Use With:XP Power ECM40/60 Series AC/DC Power Supplies; Accessory Type:Cable Harness; Product Range:ECM Series
Stock : 31

Image Description
DVIHDFM electronic component of L-Com DVIHDFM

ADAPTER, DVI-I RECEPTACLE TO HDMI PLUG
Stock : 10

MAX9890AETA+T electronic component of Analog Devices MAX9890AETA+T

Audio Amplifiers Audio Click-Pop Suppressor
Stock : 0

71-255610-06S electronic component of Amphenol 71-255610-06S

Conn Miniature Cylindrical SKT 6 POS Crimp ST Cable Mount 6 Terminal 1 Port
Stock : 143

ECM10DCMN electronic component of Sullins ECM10DCMN

20 Position ( 2 x 10 ) 3.96 mm Center Wire Wrap Dual Readout Edgecard Connector
Stock : 0

ECM100US48 electronic component of XP Power ECM100US48

Switching Power Supplies PSU, 100W, SINGLE OUTPUT, OPEN FRAME
Stock : 4

TRR10EZPF1332 electronic component of ROHM TRR10EZPF1332

TRR Series 0805 13.3 k? 0.125 W 1% 100 ppm/C Sulfur Tolerant Chip Resistor
Stock : 0

71-255010-06S electronic component of Amphenol 71-255010-06S

Conn Miniature Cylindrical SKT 6 POS Crimp ST Wall Mount 6 Terminal 1 Port
Stock : 19

ECM100US18 electronic component of XP Power ECM100US18

Switching Power Supplies PSU, 100W, SINGLE OUTPUT, OPEN FRAME
Stock : 12

ECM100US12 electronic component of XP Power ECM100US12

Switching Power Supplies PSU, 100W, SINGLE OUTPUT, OPEN FRAME
Stock : 0

154N-300A-R electronic component of TE Connectivity 154N-300A-R

Industrial Pressure Sensors 0-300psia 0-100mV Ribbon Cable
Stock : 0

ECM140 Series High Efficiency Resonant Topology 3 High Power Density 7.2 W/in Convection & Force-cooled Ratings Class I & Class II Installations Industry Standard 3.0 x 5.0 x 1.30 Format 12 V Fan Output as Standard 5 V Standby Option Remote Sense as Standard IT, Industrial & Medical Safety Approvals Remote On/Off & Power Good Signals Option Approved for Class I and Class II applications, the ECM140 range of single output AC-DC, 148 W power supplies feature high power density in an industry standard 3 x 5 (76.2 mm x 127.0 mm) footprint. The 1.30 (33.0 mm) high, 1U compatible high-density power supplies meet EN55032 Level B conducted emissions with leakage currents of 100 A at 115 VAC or 215 A at 230 VAC. Making these switchers ideal for industrial, IT and medical applications. The ECM140 series has single output versions from 12 V to 48 VDC, adjustable by 5%. All models include an additional +12V / 0.5 A fan output. They are dual-fused for compliance with IEC60601-1 and efficiency is 88% typical, so minimal excess heat is generated. The ECM140 require only 10 CFM of cooling to deliver a full 148 W of power up to +60 C and operates at up to +70 C with derating. The units also supply 120 W when convection-cooled up to +50 C with operation to +70 C with derating. Comprehensive overvoltage, overload and short circuit protection is built in. Optional A units offer a +5 V / 0.5 A standby rail, an open collector Power OK signal and Remote On/Off function. xppower.com Models and Ratings - Convection-cooled Max Fan Output Standby Supply (1) (2,3) Output Power Output Voltage V1 Model Number V3 (optional) Output Current V1 V2 120 W 12.0 VDC 10.0 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US12 120 W 15.0 VDC 8.0 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US15 120 W 18.0 VDC 6.6 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US18 120 W 24.0 VDC 5.0 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US24 120 W 28.0 VDC 4.2 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US28 120 W 48.0 VDC 2.5 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US48 Notes: 1. Convection-cooled, max output power must not exceed 120 W for combined 3. For covered versions, add suffix -C to model number or order part no. V1, V2, & V3 ECM140 COVER KIT for standalone cover. Not suitable for use in 2. For V3 5 V standby, Power OK & Inhibit, add suffix -A to model number. class II installations. Models and Ratings - Forced-cooled Max Fan Output Standby Supply (1) (2) Output Power Output Voltage V1 Model Number V3 (optional) Output Current V1 V2 148 W 12.0 VDC 11.7 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US12 148 W 15.0 VDC 9.3 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US15 148 W 18.0 VDC 7.7 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US18 148 W 24.0 VDC 5.8 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US24 148 W 28.0 VDC 5.0 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US28 148 W 48.0 VDC 2.9 A 12.0 V/0.5 A 5.0 V/0.5 A ECM140US48 Notes: 1. 10 CFM airflow. 3. For cover with Top Fan assembly add -TF to model numer, 2. For V3 5 V standby, Power OK & Inhibit, add suffix -A to model number. e.g. ECM140US12-TF or ECM140US12-ATF. Input Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Derate output power < 90 VAC. See fig. 1. Power Input Voltage - Operating 80 115/230 264 VAC OK signal cannot be used <90 VAC. Input Frequency 47 50/60 400 Hz Agency approval 47-63 Hz 230 VAC, 100% load > Power Factor 0.5 EN61000-3-2 class A compliant Input Current - No Load 0.25/0.2 A 115/230 VAC Input Current - Full Load 2.5/1.3 A 115/230 VAC Inrush Current 40 A 230 VAC cold start, 25 C 100/215 265 A 115/230 VAC/50 Hz (Typ.), 264 VAC/60 Hz (Max.) Earth Leakage Current 0.5/1.1 mA 115/230 VAC/400 Hz Input Protection T5.0A/250 V internal fuse in both line and neutral Output Characteristics Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage - V1 12 48 VDC See Models and Ratings table (V1) (V2) (V3) Initial Set Accuracy 1 , 5 & 3 % 50% load, 115/230 VAC Output Voltage Adjustment 5 % V1 only via potentiometer. See mech. details (P13). (V1 & V3) (V2) Minimum Load 0 & 0.1 A V2 min load for regulation only when used Start Up Delay 1.5 s 230 VAC full load (see fig.2) Hold Up Time 16 20 ms 115 VAC full load (see fig.3 & 4) Drift 0.2 % After 20 min warm up Line Regulation 0.5 % 90-264 VAC (V1) (V2 & V3) Load Regulation 1 , 5 % 0-100% load. V2 0.1-0.5 A load Recovery within 1% in less than 500 s Transient Response - V1 4% for a 50-75% and 75-50% load step Over/Undershoot - V1 5% See fig.5 (V1) (V2 & V3) Ripple & Noise 1 & 2 % pk-pk 20 MHz bandwidth (see fig.6 & 7) Overvoltage Protection 115 140 % Vnom DC. Output 1 only, recycle input to reset Overload Protection 110 150 % I nom Output 1 only, auto reset (see fig.8) Short Circuit Protection Continuous, trip & restart (hiccup mode) all outputs Temperature Coefficient 0.05 %/C Overtemperature Protection C Not fitted 2

Tariff Desc

8504.40.90 POWER SUPPLIES, having BOTH:
(a) input voltages of 176V-246VAC, 47Hz-63Hz single phase OR 200V-230VAC, 50Hz-60Hz single phase
(b) multiple DC output voltages from minus 200 V to positive 200V
TC 9603032

8504.40.90 CHARGERS, ADAPTERS AND INVERTERS, AC/DC OR DC/DC OR DC/AC having ALL of the following:
(a) input voltage NOT less than 10V and NOT greater than 252V
(b) output voltage NOT less than 2V and NOT greater than 252V
(c) wattage NOT less than 40 W and NOT greater than 160W
(d) output current NOT greater than 17A - TC 1021920

8504.50.10 81
(a) designed for use with equipment of 8471
(b) for telecommunication apparatus of 8517 Free

8504.40.90 POWER SUPPLY UNITS, DC AND/OR AC output, complying with AS/NZS 60950 & AS/NZS CISPR 22, having ALL of:
(a) voltage NOT less than 2.5 V and NOT greater than 55V
(b) wattage NOT less than 0.02 W and NOT greater than 105W
(c) current output NOT less than 0.01 amp and NOT greater than 2.5amp
TC 1014564

8504.40.90 POWER SUPPLY MODULES having ALL of the following:
(a) input power at EITHER of the following voltages:
(i) 120VAC/240VAC
(ii) 24VDC /48VDC
(b) output power at EITHER of the following voltages:
(i) 5VDC, +15VDC, -15VDC, and 24VDC field I/O
(ii) 24VDC field I/O only
(c) circuitry monitors
(d) output adjusters
TC 9810001

8504.40.90 POWER SUPPLIES DC having BOTH:
(a) variable voltage NOT exceeding 30V
(b) maximum current output NOT exceeding 25amps
TC 9900597

8504.40.90 CONVERTERS, DC/DC, power output not exceeding 5W, being ANY of:
(a) single in line package
(b) dual in line
(c) surface mount device
TC 9601650

8543.90.20 20 Electronic microassemblies Free

8504.40.30 Static converters
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 No Electric current rectifying assemblies Free
63 No Other Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted