Product Information

PDUMH30ATNET

PDUMH30ATNET electronic component of Tripp Lite

Datasheet
Power Outlet Strips Tripp Lite PDU Switched ATS 120V 30A 24 5-15/20R; 1 L5-30R 2 L5-30P 2URM

Manufacturer: Tripp Lite
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 827.3073 ea
Line Total: USD 827.31

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

PDUMH30ATNET
Tripp Lite

1 : USD 1506.1556
3 : USD 1373.615
5 : USD 1304.9244

0 - WHS 2


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

PDUMH30ATNET
Tripp Lite

1 : USD 827.3073
10 : USD 778.3307

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Mounting Style
Current Rating
Features
Voltage Rating
Packaging
Brand
Connector - Ac Output
Product Type
Region
Factory Pack Quantity :
Subcategory
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
PH500 electronic component of Tripp Lite PH500

Power Conditioning
Stock : 0

PDUMV15-36 electronic component of Tripp Lite PDUMV15-36

Power Outlet Strips PDU Metered 120V 15A 5-15R 13 Outlet 5-15P 36" Height 0URM
Stock : 0

PDUMV20 electronic component of Tripp Lite PDUMV20

Power Outlet Strips Metered Vertical PDU 20 Outlets 120V
Stock : 2

PDUMNV30HV2 electronic component of Tripp Lite PDUMNV30HV2

Power Outlet Strips PDU Monitored 208V / 240V 30A 36 C13; 6 C19 Outlet Vertical 0URM
Stock : 3

PDUMH30HV electronic component of Tripp Lite PDUMH30HV

Power Outlet Strips Tripp Lite PDU Metered 208V / 240V 30A 16 C13; 2 C19 L6-30P Horizontal 2URM
Stock : 0

PDUMH30HV19NET electronic component of Tripp Lite PDUMH30HV19NET

Power Outlet Strips Tripp Lite PDU Switched 208V - 240V 30A 8 C13; 6 C19 L6-30P Horizontal 2URM
Stock : 0

PDUMH30HVNET electronic component of Tripp Lite PDUMH30HVNET

Power Outlet Strips 208V 30A;L6-30 PLUG 16 C13 AC Receptacle
Stock : 0

PDUMV30HVNET electronic component of Tripp Lite PDUMV30HVNET

Power Outlet Strips 20 C13 / 4 C19 AC Recep
Stock : 0

PDUMV30HV2 electronic component of Tripp Lite PDUMV30HV2

Power Outlet Strips PDU Metered Vertical 5.8kw 208 / 240V 8 C19 40 C13 L6-30P 0U TAA
Stock : 6

PDUMV20NET electronic component of Tripp Lite PDUMV20NET

Power Outlet Strips 120V 20A L5-20P PLUG
Stock : 0

Image Description
TLM615NC20 electronic component of Tripp Lite TLM615NC20

Power Outlet Strips Tripp Lite Power Strip 120V 5-15/20R 6 Outlet Metal 15ft Cord 5-20P
Stock : 0

PS712B electronic component of Tripp Lite PS712B

Power Outlet Strips PwrStrip 5-15R 7 Out 12 Cord 5-15P BLK
Stock : 0

TLP706TELC electronic component of Tripp Lite TLP706TELC

Power Outlet Strips SurgeProtector Strip 120V 7 Outlet 6-Ft
Stock : 0

PM6SN1 electronic component of Tripp Lite PM6SN1

Power Outlet Strips 6 Outlet 6 Cord
Stock : 10

TLP128TTUSBB electronic component of Tripp Lite TLP128TTUSBB

Power Outlet Strips Surge Protector Power Strip 12 Outlet 2 USB Ports Tel/Modem/Coax
Stock : 0

PDUMV15-36 electronic component of Tripp Lite PDUMV15-36

Power Outlet Strips PDU Metered 120V 15A 5-15R 13 Outlet 5-15P 36" Height 0URM
Stock : 0

IBAR6 HG electronic component of Tripp Lite IBAR6 HG

Power Outlet Strips 6 OUT 15FT HOSP GRA 940 JOULES
Stock : 0

TLP806TELTAA electronic component of Tripp Lite TLP806TELTAA

Power Outlet Strips Surge Protector Power Strip 8 Outlet 6ft Cord Tel/DSL 3150 J TAA
Stock : 0

PS3612-20HW electronic component of Tripp Lite PS3612-20HW

Power Outlet Strips 12 OUT 20 AMP HARD WIRE
Stock : 0

PDUMV20 electronic component of Tripp Lite PDUMV20

Power Outlet Strips Metered Vertical PDU 20 Outlets 120V
Stock : 2

Management Interface Highlights Single phase 30A 120V Auto The management interface for this PDU model is transitioning to a new technology platform. The new interface Transfer Switch / ATS PDU; can be distinguished by a USB-A port (for EnviroSense2 modules) in place of the round ENVIROSENSE port. Highly reliable Solid State For managing the units containing the round port, Tripp Lite recommends using the PowerAlert Console Switching Launcher rather than a web browser. This application enables local access of the PDU using a self-contained, Enables redundant A/B power compatible Java Runtime Environment version. The Console Launcher can be downloaded for free; click the option for single-corded network above link or go to the Management Solutions / Utilities page. Units with the new interface work will with most devices current web browsers. Separate primary & secondary inputs connect to any two 2.9kW Single-Phase ATS / Switched PDU, 120V compatible power sources Outlets (24 5-15/20R, 1 L5-30R) 2 L5-30P, 2 10ft 2U rackmount, 2 L5-30P inputs, Cords, 2U Rack-Mount, TAA 25 switched outlets (24 5-15/20R, 1 L5-30R) MODEL NUMBER: PDUMH30ATNET Individually switched outlets and built-in network interface enables remote control and monitoring Digital meter reports voltage, kW load level and output amperage in 4 load segments TAA Compliant Package Includes ATS / Switched PDU with two L5-30P inputs Installable 2U mounting brackets Operating manual Description Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Highly reliable solid-state switching between primary and secondary inputs occurs in 1-5 milliseconds. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability. Features 120V 30A Power Distribution Unit (PDU) with Auto-Transfer Switch (ATS) and Switched outlets (Agency de-rated to 24A) 1 / 4 ATS features provide redundant power for critical network equipment with a single input power cord Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface Visual meter reports output amp and kW power consumption, plus voltage and temperature/humidity data with optional ENVIROSENSE sensor 25 switched outlets (24 5-15/20R & 1 L5-30R) 2U horizontal rackmount form factor; 11.9 in. / 30.2cm depth Set of two 10 ft. / 3m NEMA L5-30P input line cords enable separate PRIMARY and SECONDARY input connections ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable Highly reliable solid-state switching enables fast 1-5 millisecond trasfer between primary and secondary inputs ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series) Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols Compatible with optional ENVIROSENSE temperature monitor Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized Front panel LEDs confirm power availability on both input lines Compliant with the Federal Trade Agreements Act(TAA) for GSA Schedule purchases Specifications OVERVIEW PDU Type Auto-Transfer Switch; Switched OUTPUT 3.05kW (127V), 2.88kW (120V), 2.4kW (100V) / 30A total capacity (Agency de-rated 24A); 24A max per L5-30R Output Capacity Details outlet; 20A max per breakered load bank; 16A max per 5-15/20R outlet Frequency Compatibility 60 Hz Output Receptacles (24) 5-15/20R; (1) L5-30R Output Nominal Voltage 100; 120; 127 Overload Protection Two 20A output breakers protect 12 5-15/20R outlets each Customized Load Management 25 individually controllable outlets Receptacles INPUT PDU Input Voltage 100; 120; 127 Recommended Electrical Service 30A 120V 2 / 4

Tariff Desc

8544.42.29 718673 LEADS, EXTENSION, comprising ALL the following:
(a) NOT less than 240 volts;
(b) moulded three pin plug and socket;
(c) three core cable

8544.49.19 1517311 CABLE, having BOTH of the following:
(a) length NOT greater than 30 metres;
(b) NOT exceeding 3.3 sq/mm core

8544.42.29 933265 POWER CABLES, COMPUTER, having ALL of the following:
(a) three core cable;
(b) fitted on one end with a moulded three pin plug;
(c) NOT less than 240 volts

Tripp Lite
Tripp-Lite
Waber By Tripp Lite

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted