DC/DC Converter TEL 10WI Series, 10 Watt Most compact 10 Watt converter in DIP-16 metal casing Highest power density of 3.83 W/cm 6-side shielded metal case with insulated base plate Ultra wide 4:1 input voltage range UL 62368-1 IEC 62368-1 High efficiency for low thermal loss The TEL 10WI series is a range of isolated 10 Watt converters which come in Operating temperature range of an ultra compact DIP-16 metal package. The design purpose of these series -40C to +88C was to miniaturize low power DC/DC converters to the maximum without sacri- ficing high efficiency. The TEL 10WI series sets the new standard for power Built-in EN 55032 class A filter density with 3.83 W/cm. Protection against short circuit and The TEL 10WI series offer an ultra wide 4:1 input voltage range and feature a overload high efficiency of up to 86% which enables an operation temperature of up to +70C at full load and up to 88C with 50% load. 3-year product warranty The converters have an internal input filter to comply with conducted emission EN 55032 class A. The TEL 10WI Series models are an economical solution for space critical and cost sensitive applications in instrumentation, IT and industri- al electronics. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TEL 10-2410WI 3.3 VDC 2 700 mA 80 % TEL 10-2411WI 5.1 VDC 2 000 mA 83 % TEL 10-2412WI 12 VDC 833 mA 87 % 9 - 36 VDC TEL 10-2413WI 15 VDC 666 mA 88 % (24 VDC nom.) TEL 10-2415WI 24 VDC 416 mA 88 % TEL 10-2422WI +12 VDC 416 mA 12 VDC 416 mA 87 % TEL 10-2423WI +15 VDC 333 mA 15 VDC 333 mA 87 % TEL 10-4810WI 3.3 VDC 2 700 mA 80 % TEL 10-4811WI 5.1 VDC 2 000 mA 83 % TEL 10-4812WI 12 VDC 833 mA 87 % 18 - 75 VDC TEL 10-4813WI 15 VDC 666 mA 88 % (48 VDC nom.) TEL 10-4815WI 24 VDC 416 mA 88 % TEL 10-4822WI +12 VDC 416 mA 12 VDC 416 mA 87 % TEL 10-4823WI +15 VDC 333 mA 15 VDC 333 mA 87 % Page 1 / 4 www.tracopower.com June 16, 2021TEL 10WI Series, 10 Watt Input Specifications Input Current - At no load 24 Vin models: 10 mA typ. 48 Vin models: 7 mA typ. - At full load 24 Vin models: 480 mA max. 48 Vin models: 240 mA max. Surge Voltage 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Under Voltage Lockout 24 Vin models: 7 VDC min. / 8 VDC typ. 48 Vin models: 15 VDC min. / 16 VDC typ. Recommended Input Fuse 24 Vin models: 2 000 mA (slow blow) 48 Vin models: 1 000 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Output Specifications Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.8% max. dual output models: 0.8% max. - Load Variation (0 - 100%) single output models: 1% max. dual output models: 2% max. (Output 1) 2% max. (Output 2) - Cross Regulation dual output models: 5% max. (25% / 100% asym. load) Ripple and Noise - single output 3.3 Vout models: 60 mVp-p typ. (20 MHz Bandwidth) 5.1 Vout models: 60 mVp-p typ. 12 Vout models: 80 mVp-p typ. 15 Vout models: 80 mVp-p typ. 24 Vout models: 80 mVp-p typ. - dual output 12 / -12 Vout models: 80 / 80 mVp-p typ. 15 / -15 Vout models: 80 / 80 mVp-p typ. - single output 3.3 Vout models: 75 mVp-p max. 5.1 Vout models: 75 mVp-p max. 12 Vout models: 100 mVp-p max. 15 Vout models: 100 mVp-p max. 24 Vout models: 100 mVp-p max. - dual output 12 / -12 Vout models: 100 / 100 mVp-p max. 15 / -15 Vout models: 100 / 100 mVp-p max. Capacitive Load - single output 3.3 Vout models: 2 600 F max. 5.1 Vout models: 1 300 F max. 12 Vout models: 560 F max. 15 Vout models: 560 F max. 24 Vout models: 200 F max. - dual output 12 / -12 Vout models: 390 / 390 F max. 15 / -15 Vout models: 200 / 200 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Start-up Time 30 ms typ. / 60 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 195% max. of Iout max. 160% typ. of Iout max. Transient Response - Response Deviation 5% max. (25% Load Step) - Response Time 500 s max. (25% Load Step) All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com June 16, 2021