DC/DC Converter TEL 10 Series, 10 Watt Most compact 10 Watt converter in DIP-16 metal casing Highest power density of 3.83 W/cm 6-side shielded metal case with insulated base plate Wide 2:1 input voltage range UL 62368-1 IEC 62368-1 High efficiency for low thermal loss The TEL 10 series is a range of isolated 10 Watt DC/DC converters which Operating temperature range of come in a ultra compact DIP-16 metal package. The design purpose of these -40C to +88C series was to miniaturized low power DC/DC converters to the maximum with- out sacrificing high efficiency. The TEL 10 series sets the new standart for Built-in EN 55032 class A filter power density with 3.83 W/cm. Current limitation and protection The TEL 10 series offers a wide 2:1 input voltage range and features a high ef- against short circuit ficiency of up to 88% which enables an operation temperature of up to +70C at full load and up to 85C with 50% load. 3-year product warranty The converters have an internal input filter to comply with conducted emission EN 55032 class A. The TEL 10 Series models feature an overall economical so- lution for space critical and cost sensitive applications in instrumentation, IT and industrial electronics. Models Order Code Input Voltage Output 1 Output 2 Efficiency Range Vnom Imax Vnom Imax typ. TEL 10-1210 3.3 VDC 2 700 mA 79 % TEL 10-1211 5.1 VDC 2 000 mA 82 % TEL 10-1212 12 VDC 833 mA 86 % 9 - 18 VDC TEL 10-1213 15 VDC 666 mA 87 % (12 VDC nom.) TEL 10-1215 24 VDC 416 mA 87 % TEL 10-1222 +12 VDC 416 mA 12 VDC 416 mA 86 % TEL 10-1223 +15 VDC 333 mA 15 VDC 333 mA 86 % TEL 10-2410 3.3 VDC 2 700 mA 80 % TEL 10-2411 5.1 VDC 2 000 mA 83 % TEL 10-2412 12 VDC 833 mA 87 % 18 - 36 VDC TEL 10-2413 15 VDC 666 mA 88 % (24 VDC nom.) TEL 10-2415 24 VDC 416 mA 88 % TEL 10-2422 +12 VDC 416 mA 12 VDC 416 mA 87 % TEL 10-2423 +15 VDC 333 mA 15 VDC 333 mA 87 % TEL 10-4810 3.3 VDC 2 700 mA 80 % TEL 10-4811 5.1 VDC 2 000 mA 83 % TEL 10-4812 12 VDC 833 mA 87 % 36 - 75 VDC TEL 10-4813 15 VDC 666 mA 88 % (48 VDC nom.) TEL 10-4815 24 VDC 416 mA 88 % TEL 10-4822 +12 VDC 416 mA 12 VDC 416 mA 87 % TEL 10-4823 +15 VDC 333 mA 15 VDC 333 mA 87 % Page 1 / 4 www.tracopower.com June 16, 2021TEL 10 Series, 10 Watt Input Specifications Input Current - At no load 12 Vin models: 20 mA typ. 24 Vin models: 10 mA typ. 48 Vin models: 8 mA typ. - At full load 12 Vin models: 970 mA typ. 24 Vin models: 480 mA typ. 48 Vin models: 240 mA typ. Surge Voltage 12 Vin models: 25 VDC max. (1 s max.) 24 Vin models: 50 VDC max. (1 s max.) 48 Vin models: 100 VDC max. (1 s max.) Under Voltage Lockout 12 Vin models: 7 VDC min. / 8 VDC typ. 24 Vin models: 15 VDC min. / 16 VDC typ. 48 Vin models: 31 VDC min. / 34 VDC typ. Recommended Input Fuse 12 Vin models: 2 000 mA (slow blow) 24 Vin models: 1 000 mA (slow blow) 48 Vin models: 500 mA (slow blow) (The need of an external fuse has to be assessed in the final application.) Input Filter Internal Pi-Type Output Specifications Voltage Set Accuracy 1% max. Regulation - Input Variation (Vmin - Vmax) single output models: 0.8% max. dual output models: 0.8% max. - Load Variation (0 - 100%) single output models: 1% max. dual output models: 2% max. (Output 1) 2% max. (Output 2) - Cross Regulation dual output models: 5% max. (25% / 100% asym. load) Ripple and Noise - single output 3.3 Vout models: 60 mVp-p typ. (20 MHz Bandwidth) 5.1 Vout models: 60 mVp-p typ. 12 Vout models: 80 mVp-p typ. 15 Vout models: 80 mVp-p typ. 24 Vout models: 80 mVp-p typ. - dual output 12 / -12 Vout models: 80 / 80 mVp-p typ. 15 / -15 Vout models: 80 / 80 mVp-p typ. - single output 3.3 Vout models: 72 mVp-p max. 5.1 Vout models: 72 mVp-p max. 12 Vout models: 96 mVp-p max. 15 Vout models: 96 mVp-p max. 24 Vout models: 96 mVp-p max. - dual output 12 / -12 Vout models: 96 / 96 mVp-p max. 15 / -15 Vout models: 96 / 96 mVp-p max. Capacitive Load - single output 3.3 Vout models: 2 600 F max. 5.1 Vout models: 1 300 F max. 12 Vout models: 560 F max. 15 Vout models: 560 F max. 24 Vout models: 200 F max. - dual output 12 / -12 Vout models: 390 / 390 F max. 15 / -15 Vout models: 200 / 200 F max. Minimum Load Not required Temperature Coefficient 0.02 %/K max. Start-up Time 30 ms typ. / 60 ms max. Short Circuit Protection Continuous, Automatic recovery Output Current Limitation 192% max. of Iout max. 160% typ. of Iout max. All specifications valid at nominal voltage, full load and +25C after warm-up time unless otherwise stated. Page 2 / 4 www.tracopower.com June 16, 2021