Product Information

76-1486

76-1486 electronic component of Tenma

Datasheet
BANANA JACK, 4MM, 36A, M4 STUD, GREEN

Manufacturer: Tenma
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 5.3532 ea
Line Total: USD 5.35

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

76-1486
Tenma

1 : USD 5.3532
100 : USD 4.5984
250 : USD 4.351
500 : USD 4.2315
1000 : USD 4.1462

     
Manufacturer
Product Category
Current Rating
Contact Plating
Brand
Gender
Connector Mounting
Voltage Rating
Connector Colour
Contact Material
Contact Termination Type
Svhc
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
76-1492 electronic component of Tenma 76-1492

BANANA JACK, 4MM, 36A, QC, BLUE
Stock : 0

76-1494 electronic component of Tenma 76-1494

BANANA JACK, 4MM, 36A, QC, GREEN
Stock : 0

76-1496 electronic component of Tenma 76-1496

BANANA JACK, 4MM, 36A, QC, YELLOW
Stock : 0

76-1488 electronic component of Tenma 76-1488

BANANA JACK, 4MM, 36A, M4 STUD, YELLOW
Stock : 0

76-1500 electronic component of Tenma 76-1500

BANANA JACK, 4MM, 25A, SOLDER, BLUE
Stock : 0

76-1502 electronic component of Tenma 76-1502

BANANA JACK, 4MM, 25A, SOLDER, GREEN
Stock : 0

76-1504 electronic component of Tenma 76-1504

BANANA JACK, 4MM, 25A, SOLDER, YEL
Stock : 0

76-1508 electronic component of Tenma 76-1508

BANANA JACK, 4MM, 25A, SOLDER, BLUE
Stock : 0

76-1510 electronic component of Tenma 76-1510

BANANA JACK, 4MM, 25A, SOLDER, GREEN
Stock : 0

76-1516 electronic component of Tenma 76-1516

BANANA JACK, 4MM, 25A, SOLDER, BLK
Stock : 0

Image Description
76-1488 electronic component of Tenma 76-1488

BANANA JACK, 4MM, 36A, M4 STUD, YELLOW
Stock : 0

76-1648 electronic component of Tenma 76-1648

BANANA PLUG, 4MM, 36A, SCREW, BLK
Stock : 0

76-1640 electronic component of Tenma 76-1640

BANANA PLUG, 4MM, 36A, SOLDER, BLACK
Stock : 0

76-1642 electronic component of Tenma 76-1642

BANANA PLUG, 4MM, 36A, SOLDER, RED
Stock : 0

76-1644 electronic component of Tenma 76-1644

BANANA PLUG, 4MM, 36A, SCREW, BLACK
Stock : 0

76-1646 electronic component of Tenma 76-1646

BANANA PLUG, 4MM, 36A, SCREW, RED
Stock : 0

E2BS08KS02WPB12MOMI electronic component of Omron E2BS08KS02WPB12MOMI

INDUCTIVE PROXIMITY SENSOR, 2MM, 30VDC
Stock : 0

E2E-X2D1-M1G OMS electronic component of Omron E2E-X2D1-M1G OMS

INDUCTIVE PROXIMITY SENSOR, 2MM, 24VDC
Stock : 0

E2E-X3D1-M1G OMS electronic component of Omron E2E-X3D1-M1G OMS

INDUCTIVE PROXIMITY SENSOR, 3MM, 24VDC
Stock : 0

E2E-X3D1-N 2M OMS electronic component of Omron E2E-X3D1-N 2M OMS

INDUCTIVE PROXIMITY SENSOR, 3MM, 24VDC
Stock : 0

I gather the set of wrenches part number 76-1706, an open-end spanner SW6 (6 mm), a panel with the specifications below, and a tool to drill or punch out the panel as below. 11.0 0.5 mm Panel material : 6.0 insulating. Panel. Pitch circle diameter to 12.0(+0.1/-0) mm Maxi. drill the panel : Outline to punch out the thickness : 10 mm 12.0(+0.1/-0) mm panel. I drill or punch out the panel as above with the tool. If the round nut is screwed on the socket then I remove it. I push the socket into the hole of the panel as shown below. With my hand I screw the round nut on the socket as shown below. 2.8 21.2 10.0 Panel. Round nut. Indentations of the round nut. 4 mm banana side of the socket. Front face 6 Rear face of the panel. of the panel. I insert the thin wrench of part number 76-1706 into the 4 mm banana side of the socket as shown below. I insert the large wrench of part number 76-1706 into the indentations of the round nut as shown below. 14.2 14.5 M12 x 0.75 mm M4 Thin wrench of part number 76-1706. Large wrench of part number 76-1706. The 4 mm banana Round nut to attach the Flat surface Terminal : M4 threaded stud and socket to the panel by female connection for anti- 2 M4 nuts (complying with both I hold one wrench with my hand and the other wrench with my other complies with the 4 screwing with the rotation lead-tin and lead-free tin soldering hand. I rotate to screw and tighten the round nut (2.3 N.m maxi. torque). wrenches of part number European mm banana plugs of purpose (if and 150 W maximum soldering Union the worldwide most 76-1706. Tightening needed). iron). Screwing by open-end Now the socket is attached to the panel. Depending on my application I torque, 2.3 N.m maxi. marking. famous manufacturers. spanner SW6 (6 mm). Tightening achieve the connection with the M4 threaded stud by using the two M4 (at 20 C). nuts provided and the open-end spanner SW6 (6 mm) (tightening torque, torque, 0.3 N.m maxi. (at 20 C). 0.3 N.m maxi.). Then the socket is ready to use. Fichier DataSheet TENMA 3265-I . 12/10/2016. Indice A. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. 2016. Dimensions in millimeters. ACCESSIBLE. Able to be touched with a standard test finger or test pin. BASIC INSULATION. Insulation of HAZARDOUS LIVE parts which provides basic protection. CAT II. Measurement or overvoltage category II. For measurement per- formed on / equipment connected to the building wiring. CAT III. Measurement or overvoltage category III. For measurement performed on / equipment connected to part of a building wiring installation. CAT IV. Measurement or overvoltage category IV. For measurement performed on / equipment connected to the origin of the electrical supply to a building. CLEARANCE. Shortest distance in air between two conductive parts. CREEPAGE DISTANCE. Shortest distance along the surface of a solid The design of the socket front face meets the requirements of EN / IEC 61010-031:2008 and the insulating material between two conductive parts. socket design is compatible with EN / IEC 61010-1:2010 for reinforced insulation at 1000 V CTI. Comparative Tracking Index of the insulating material in accordance with IEC 60112. CAT II / 1000 V CAT III / 600 V CAT IV and 36 A (at 40 C). DOUBLE INSULATION. Insulation comprising both BASIC INSULATION These specifications come from the creepage distances, clearances, solid insulation, and CTI of and SUPPLEMENTARY INSULATION. the socket. And the considered building and implementation specifications are : insulating panel EN / IEC 60529:2001. The 2001 version of the European / international standard regarding the degrees of protection provided by enclosures. pollution degree of the micro-environment, 1 or 2 relative humidity of the micro-environment, 80 % maximum for temperatures up to 31 C decreasing linearly to 50 % relative humidity at 40 EN / IEC 61010-1:2010. The latest version (in February 2012) of the European / international standard regarding the safety requirements for C temperature range of the micro-environment, +5 C to +40 C indoor use and altitude, 2000 electrical equipment for measurement, control, and laboratory use Part 1: General requirements. Version year 2010. m maximum. IP2X (touch-protected) protection on the front face according to EN / IEC 60529. EN / IEC 61010-031:2008. The latest version (in February 2012) of the European / international standard regarding the safety requirements for electrical equipment for measurement, control and laboratory use Part 031: -20 C mini., +80 C maxi. (please see above too). Safety requirements for hand-held probe assemblies for electrical measure- ment and test. Version year 2008. LV. European Directive 2006/95/EC on the harmonisation of the laws of The socket design is compatible with the EN / IEC 61010-031:2008 requirements of protection Member States relating to electrical equipment designed for use within certain voltage limits. (Usually called the Low Voltage Directive.) against the spread of fire and resistance to heat by its basic insulation. The socket design is com- MAINS. Low-voltage electricity supply system to which the equipment patible with the EN / IEC 61010-1:2010 requirements of eliminating / reducing the sources of concerned is designed to be connected for the purpose of powering the equipment. ignition within the equipment by its basic insulation. The socket isn t designed to comply with the MAINS CIRCUIT. Circuit which is intended to be directly connected to the building of equipment containing or using flammable liquids and with circuits producing heat. MAINS for the purpose of powering the equipment. OVERVOLTAGE CATEGORY. Numeral defining a TRANSIENT OVER- VOLTAGE condition. European DirectiveLow Voltage Directiv 2014/35/EU. POLLUTION. Addition of foreign matter, solid, liquid or gaseous (ionized European DirectiveRoH 2011/65/EU. gases), that may produce a reduction of dielectric strength or surface European REACH regulation n1907 / 2006. resistivity. International / European standard EN / IEC 61010-031:2008. POLLUTION DEGREE. Numeral indicating the level of POLLUTION that may be present in the environment. International / European standard EN / IEC 61010-1:2010. POLLUTION DEGREE 1. No POLLUTION or only dry, non-conductive International / European standard EN / IEC 60529. POLLUTION occurs, which has no influence. POLLUTION DEGREE 2. Only non-conductive POLLUTION occurs except that occasionally a temporary conductivity caused by condensation is RoH compliant, Pb 4 % in conductor, Pb 0.1 % in insulator, Hg 0.1 %, Cr VI 0.1 %, expected. Cd 0.01 %, PBB 0.1 %, and PBDE 0.1 %. REINFORCED INSULATION. Insulation which provides protection against REACH compliant, no substances from the candidate list of SVHC for authorisation at mass electric shock not less than that provided by DOUBLE INSULATION. concentrations greater than 0.1 % RoH. European Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment. SOLID INSULATION. Insulating materials. Conductors : nickel-coated brass. Insulator : please contact us, CTI < 175. SUPPLEMENTARY INSULATION. Independent insulation applied in addition to BASIC INSULATION in order to provide protection Black Red Yellow Green Blue White against electric shock in the event of a failure of BASIC INSULATION. TRANSIENT OVERVOLTAGE. Short duration overvoltage of a few milliseconds or less, oscillatory or non-oscillatory, usually highly damped. 0.007 kg. WORKING VOLTAGE. Highest r.m.s. value of the a.c. or d.c. voltage across any particular insulation which can occur when the equipment is Designed and manufactured in France. supplied at rated voltage. Year of 1st placing on the market 1996. One piece per bag (in one bag : 1 socket + 1 round nut + 2 M4 nuts). Fichier DataSheet TENMA 3265-I . 12/10/2016. Indice A. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. 2016.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted