Product Information

LPD70

LPD70 electronic component of Teledyne

Datasheet
Teledyne Relays Solid State Relays - PCB Mount 250mA 28VDC MILSPEC

Manufacturer: Teledyne
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 221.3867 ea
Line Total: USD 221.39

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 17 May to Thu. 23 May

MOQ : 1
Multiples : 1

Stock Image

LPD70
Teledyne

1 : USD 243.36
9 : USD 219.4452
23 : USD 216.6696
47 : USD 205.8372

0 - WHS 2


Ships to you between Fri. 17 May to Thu. 23 May


Multiples : 48

Stock Image

LPD70
Teledyne


0 - WHS 3


Ships to you between Thu. 23 May to Mon. 27 May

MOQ : 1
Multiples : 1

Stock Image

LPD70
Teledyne

1 : USD 546.894
10 : USD 540.7185

     
Manufacturer
Product Category
Control Voltage Range
Load Voltage Rating
Load Current Rating
Input Current
Mounting Style
Packaging
Minimum Operating Temperature
Maximum Operating Temperature
Series
Length
Width
Height
Brand
Product
Termination Style
Input To Output Isolation Method
Hts Code
Product Type
Factory Pack Quantity :
Subcategory
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
LR1200480D25-021 electronic component of Teledyne LR1200480D25-021

Solid State Relay - Line Voltage 48-530VAC - Control Voltage Range 3-32 VDC - Output 25A
Stock : 40

LR600240A40 electronic component of Teledyne LR600240A40

Solid State Relay - Line Voltage 24-280VAC - Control Voltage Range 90-280 VAC - Output 40A
Stock : 13

LRMOSD5050R25H electronic component of Teledyne LRMOSD5050R25H

Solid State Relay - DC Out - Max Line Voltage 50VAC - Control Voltage Range 15-32 VDC - Output 25A
Stock : 443

LRT600240A25 electronic component of Teledyne LRT600240A25

Solid State Relay - Triac - Line Voltage 24-280VAC - Control Voltage Range 90-280 VAC - Output 25A
Stock : 5

LR1200480A40 electronic component of Teledyne LR1200480A40

Solid State Relay - Line Voltage 48-530VAC - Control Voltage Range 90-280 VAC - Output 40A
Stock : 3

LR600240R25 electronic component of Teledyne LR600240R25

Solid State Relays - PCB Mount RO 558-LR600240D25R
Stock : 2

LRIGTD600240R25L electronic component of Teledyne LRIGTD600240R25L

Solid State Relay - DC Out - Line Voltage 24-400VDC - Control Voltage Range 3.5-15 VDC - Output 25A
Stock : 8

LRT600240A10 electronic component of Teledyne LRT600240A10

Solid State Relay - Triac - Line Voltage 24-280VAC - Control Voltage Range 90-280 VAC - Output 10A
Stock : 18

LR1200480D40 electronic component of Teledyne LR1200480D40

LR1200480D40 teledyne
Stock : 0

LR600240D25 electronic component of Teledyne LR600240D25

SOLID STATE RELAY 24-280 V - PCB SSR 280VAC/25A, DC In, ZC
Stock : 0

Image Description
LR1200480D25 electronic component of Sensata LR1200480D25

Crydom Solid State Relays - PCB Mount 0.15-25A 4-32VDC
Stock : 38

LR600240D25 electronic component of Sensata LR600240D25

Solid State Relays - PCB Mount PCB SSR 280VAC/25A DC In, ZC
Stock : 44

LR600240D40 electronic component of Sensata LR600240D40

Solid State Relays - PCB Mount PCB SSR 280VAC/40A DC In, ZC
Stock : 18

LS240D8R electronic component of Sensata LS240D8R

Solid State Relays - PCB Mount 0.15-8A 4-10VDC
Stock : 19

LSE240D8 electronic component of Sensata LSE240D8

Solid State Relays - PCB Mount 20-28VDC 12A Z / C
Stock : 40

SZD20CFT electronic component of Teledyne SZD20CFT

Solid State Relays - PCB Mount 2A 60VDC Thru-Hole
Stock : 0

SZD20CDT electronic component of Teledyne SZD20CDT

Solid State Relays - PCB Mount 1A 80VDC Circ. Protect SMT
Stock : 0

LPD70 Series 250mA, 28Vdc Optically Isolated Dual Relay Part Number Description LPD70 250mA, 28Vdc dual solid-state relay MECHANICAL SPECIFICATION FEATURES/BENEFITS Current limiting output Thermal protection Automatic recovery Overload protection Dual output: Two relays in one package Low voltage drop MAXIMUM DESCRIPTION The LPD70 is a dual-output 28Vdc plastic relay with internal thermal protection. The relay utilizes optical isolation to provide excellent input-to-output isolation. Figure 1 LPD70 relay dimensions in inches (mm) The LPD70 offers a current limiting output to protect Tolerances are +/- .005 inch (.127) unless otherwise itself and associated load circuits from transient current specified overloads. During an overcurrent condition, the LPD70 clamps the current to a safe operating value. The INPUT (CONTROL) SPECIFICATIONS LPD70 also offers thermal protection. The thermal (40 to 85C) protection is activated by junction temperature. In case Min Max Units of an overload or shorted load condition, the thermal Control Voltage Range 4.0 7.0 Vdc protection limits the junction temperature. The LPD70 (See Note ) returns to normal operation automatically once the Input Current 5 Vdc (See Fig 2) 2 mA overload is removed. Must Turn-On Voltage 4 Vdc Must Turn-Off Voltage 0.8 Vdc Must Turn-Off Current 50 A Reverse Voltage 7 Vdc TM NERU R TPUN) ) N P O U L T T A G 6 E 6 D C INPUT CURRENT VS. INPUT VOLTAGE Figure 2 2007 TELEDYNE RELAYS (800) 284-7007 www.teledynerelays.com Page 2DSLPD70 Rev. BLPD70 Series 250mA, 28Vdc Optically Isolated Dual Relay OUTPUT (LOAD) SPECIFICATIONS Min Max Units Load Voltage Rating 33 Vdc 9 2%, 9 2%, Load Current (See Fig 6) 0.25 A ). /54 ). /54 Transient Voltage 80 Vdc n n n n Transient Supply Voltage 0). with Load shorted (5 sec max) 46 Vdc Output Capacitance 25Vdc 200 pF On-State Voltage Drop (See Fig 4) 0.5 Vdc 6DC On Resistance 2.0 Ohm Off-State Leakage Current (33Vdc) 0 A 6 Turn-On Time 2.5 ms Turn-Off Time ms 6 SUPPLY 6DC Overload Current Limit (See Fig 5) 0.9 A ,OAD ,OAD YPICAL 4 6 OVERLOAD/THERMAL PROTECTION SPECIFICATIONS (NOTE 8) TYPICAL WIRING DIAGRAM Min Typical Max Units Figure 3 Output Load Voltage 33 Vdc Junction Activation 50 C Temperature o Output Current (after 20 sec) 60 mArms Activation Time (See Fig. 7, Note7) 70 ms o o n ENVIRONMENTAL SPECIFICATIONS Min Max Units Operating Temperature 40 +85 C TNE RRU DAO , Storage Temperature 55 + 00 C Junction Temperature 00 C Thermal Resistance (Junction to Ambient) each relay 20 C/W Shock 500 g Vibration 00 g / U T P O U L T T A 6G E RO P 6 Dielectric Strength 500 Vac LOAD CURRENT VS. OUTPUT VOLTAGE DROP OVER TEMPERATURE Insulation Resistance 9 ( 500 Vdc) 0 Ohm Figure 4 Isolation 5 pF Resistance to Solder Dip, 0 seconds at +260C Soldering Heat MIL STD 202, method 2 0 Solderability MIL STD 202, method 208 Thermal Shock MIL STD 202, method 07 HAST JEDEC Test Method A 0 30C 85% RH, no power /VERLOAD URRENT ,IMIT applied, 50 hours n n n n EMPERATURE MBIENT 4 TYPICAL OVERLOAD CURRENT VS. TEMPERATURE Figure 5 Page 2 SPECIFICATIONS UNDER REVISION CONTROL 2007 TELEDYNE RELAYS 2DSLPD70 Rev. B

Tariff Desc

8536.49.00 RELAYS, solid state, having an operating voltage NOT exceeding
600 V AC or 300 V DC, but NOT including protective monitoring TC 9320885

ELECTRICAL APPARATUS FOR SWITCHING OR PROTECTING ELECTRICAL CIRCUITS, OR FOR MAKING CONNECTIONS TO OR IN ELECTRICAL CIRCUITS FOR EXAMPLE, SWITCHES, RELAYS.
TELEDYNE COAX
Teledyne e2v
TELEDYNE INDUSTRIAL
Teledyne LeCroy
Teledyne LeCroy Inc
TELEDYNE MICROWAVE SOLUTIONS
TELEDYNE MIL SSR
TELEDYNE RELAYS
Teledyne Technologies

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted