Product Information

E1PF400VSY01

E1PF400VSY01 electronic component of Tele

Datasheet
RELAY, VOLTAGE SENSING, SPDT, 400VAC

Manufacturer: Tele
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 119.5392 ea
Line Total: USD 119.54

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1
1 : USD 113.5595

     
Manufacturer
Product Category
Product
Type
Contact Current Rating
Mounting Type
Supply Voltage Max
Power Consumption
Contact Voltage Vac
Contact Voltage Vdc
Contact Configuration
Relay Terminals
Relay Mounting
Approvals Standards
Svhc
Contact Current Ac Max
Contact Voltage Ac Max
External Depth
External Length / Height
External Width
Nom Input Voltage
Timer Functions
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
G2LM20 230VAC electronic component of Tele G2LM20 230VAC

LEVEL MONITORING, 230VAC
Stock : 0

E3ZM20 electronic component of Tele E3ZM20

MULTIFUNCTION (7 FT.)
Stock : 0

E1ZMQ10 electronic component of Tele E1ZMQ10

MULTIFUNCTION (4 FT.)
Stock : 0

E1ZM10 12-240VAC/DC electronic component of Tele E1ZM10 12-240VAC/DC

TIMER, MULTIFUNCTION, 12-240VAC/DC
Stock : 0

G2IM5AL20 24-240VAC/DC electronic component of Tele G2IM5AL20 24-240VAC/DC

RELAY, CURRENT SENSING, DPDT, 5A
Stock : 0

G2PF400VS02 electronic component of Tele G2PF400VS02

RELAY, VOLTAGE SENSING, DPDT, 400VAC
Stock : 0

G2PM400VSY20 24-240VAC/DC electronic component of Tele G2PM400VSY20 24-240VAC/DC

RELAY, VOLTAGE SENSING, DPDT, 240V
Stock : 0

G2ASMA20 electronic component of Tele G2ASMA20

PUMP CONTROL, ALTERNATING/PARALLEL
Stock : 0

E1YU400V01 electronic component of Tele E1YU400V01

RELAY, VOLTAGE SENSING, SPDT, 400VAC
Stock : 0

E1YF400V01 0,85 electronic component of Tele E1YF400V01 0,85

RELAY, VOLTAGE SENSING, SPDT, 400VAC
Stock : 0

Image Description
SKA20420 electronic component of Celduc SKA20420

Relay: solid state; SPST-NO; Ucntrl:4÷30VDC; 5A; 12÷275VAC
Stock : 80

DWRS220A electronic component of Crouzet DWRS220A

Industrial Relays DIN RAIL, 3x220VAC PHASE CTRL RLY
Stock : 16

DUR110A electronic component of Crouzet DUR110A

Industrial Relays DIN RAIL, 110VAC VLTGE CTRL RLY
Stock : 3

MT-63/3K-50 electronic component of Altech MT-63/3K-50

Industrial Relays Overload Relay for MC-50A~65A
Stock : 0

MT-95/3K-75 electronic component of Altech MT-95/3K-75

Industrial Relays Overload Relay for
Stock : 1

GN325DSZ electronic component of Crouzet GN325DSZ

Relay: solid state; Ucntrl:4÷32VDC; 25A; 48÷600VAC; 3-phase
Stock : 0

GNR10DCZ electronic component of Crouzet GNR10DCZ

Relay: solid state; Ucntrl:4÷32VDC; 10A; 24÷280VAC; DIN, on panel
Stock : 2

GNR25DCZ electronic component of Crouzet GNR25DCZ

Relay: solid state; Ucntrl:4÷32VDC; 25A; 48÷600VAC; 3-phase
Stock : 7

DS7-342SX024N0-N electronic component of Eaton DS7-342SX024N0-N

Module: soft-start; Usup:200÷480VAC; DIN; 11kW; Ucntrl:110÷230VAC
Stock : 0

DS7-340SX032N0-N electronic component of Eaton DS7-340SX032N0-N

Module: soft-start; Usup:200÷480VAC; DIN; 24VDC; 15kW; 0÷30/0÷30s
Stock : 2

Voltage monitoring in 3-phase mains E1PF400VSY01 Monitoring relays - ENYA series Monitoring of phase sequence and phase failure Monitoring of asymmetry Connection of neutral wire optional Supply voltage = measuring voltage 1 change over contact Width 17.5mm Installation design Technical data 1. Functions 7. Measuring circuit Monitoring of phase sequence, phase failure and asymmetry with Measuring variable: 3(N)~, sinus, 48 to 63Hz adjustable asymmetrie, connection of neutral wire optional. Measuring input: (= supply voltage) Terminals: (N)-L1-L2-L3 2. Time ranges Overload capacity: determined by tolerance Adjustment range specified for supply voltage Tripping delay: fixed, approx. 100ms Input resistance: - Asymmetry: 5% ... 25% 3. Indicators Overvoltage category: III (in accordance with IEC 60664-1) Green LED ON: indication of supply voltage Rated surge voltage: 4kV Yellow LED ON/OFF: indication of relay output 8. Accuracy 4. Mechanical design Base accuracy: 5% (of nominal value) Self-extinguishing plastic housing, IP rating IP40 Adjustment accuracy: 5% Mounted on DIN-rail TS 35 according to EN 60715 Repetition accuracy: 2% Mounting position: any Voltage influence: - Shockproof terminal connection according to VBG 4 (PZ1 required), Temperature influence: 0.05% / C IP rating IP20 Tightening torque: max. 1Nm 9. Ambient conditions Terminal capacity: Ambient temperature: -25 to +55C 2 1 x 0.5 to 2.5mm with/without multicore cable end Storage temperature: -25 to +70C 2 1 x 4mm without multicore cable end Transport temperature: -25 to +70C 2 2 x 0.5 to 1.5mm with/without multicore cable end Relative humidity: 15% to 85% 2 2 x 2.5mm flexible without multicore cable end (in accordance with IEC 60721-3-3 class 3K3) Pollution degree: 2, if built in 3 5. Input circuit (in accordance with IEC 60664-1) Supply voltage: (= measured voltage) Terminals: (N)-L1-L2-L3 10. Weight Rated voltage UN: see table ordering information or Single packing: 72g printing on the unit Packing of 10pcs: 670g per Package Tolerance: -30% to +30% of UN Rated consumption: 8VA (0,8W) Rated frequency: AC 48 to 63Hz Duty cycle: 100% Reset time: 500ms Hold-up time: - Drop out voltage: >20% of the supply voltage Overvoltage category: III (in accordance with IEC 60664-1) Rated surge voltage: 4kV 6. Output circuit 1 potential free change over contact Rated voltage: 250V AC Switching capacity: 1250VA (5A / 250V AC) Fusing: 5A fast acting 6 Mechanical life: 20 x 10 operations 5 Electrical life: 2 x 10 operations at 1000VA resistive load Switching frequency: max. 6/min at 1000VA resistive load (in accordance with IEC 60947-5-1) Overvoltage category: III (in accordance with IEC 60664-1) Rated surge voltage: 4kV www.tele-online.comE1PF400VSY01 Functions Connections Phase sequence monitoring L1 When all the phases are connected in the correct sequence and the L2 3N~ measured asymmetry is less than the fixed value, the output relay L3 switches into on-position (yellow LED illuminated). When the phase N sequence changes, the output relay switches into off-position (yellow N L3 LED not illuminated). L1 L2 11 R 1 2 14 11 12 14 berwachung Phasenausfall Das Ausgangsrelais R fllt ab (gelbe LED leuchtet nicht), wenn eine der Phasen ausfllt. Dimensions Asymmetry monitoring The output relay R switches into off-position (yellow LED not illuminated) when the asymmetrie exceeds the value set at the ASYM-regulator. Reverse voltages of a consumer (e.g. a motor which continues to run on two phases only) do not effect the disconnection. 5mm 44mm 17,5mm 60mm Ordering Informations Types Rated voltage U Switching thresholds Part. No. (PQ 1) Part. No. (PQ 10) N E1PF400VSY01 3(N)-400/230V Asymmetrie 5%...25% 1340300 1340300A RELEASE 2009/07 Subject to alterations and errors www.tele-online.com 45mm 87mm

Tariff Desc

8536.49.00 TC17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC8909066 RELAYS having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mmx30mmx27mm

8536.49.00 TC9613322 RELAYS low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24mm
(b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8AAC

8536.49 TC8906734 RELAYS having ALL of the following:
(a) one, two or three contacts
(b) maximum continuous contact current rating of NOT less than 15A
(c) maximum contact voltage rating of NOT less than 380V
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC1122469 RELAYS having an operating voltage NOT exceeding 250volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC8534635 RELAYS cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5A (AC or DC);
(b) switching voltage NOT exceeding 250V (AC or DC);
(c) body dimensions NOT exceeding 31mm x36mm x19mm

8536.49 TC8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following:
(a) normally closed main poles;
(b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8538.90.90 08 .. For programmable controllers Other Free

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted