Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 High Frequency Power Line Filter or Power Entry Module AQ Series UL Recognized CSA Certied 3VAQ8F 6VAQ8F AQ Series Specications Low cost solution to power line noise at high Maximum leakage current each Line to Ground: 3A Models 6A Models frequencies 120 VAC 60 Hz: 1.2 mA .7 mA High common and differential mode performance 250 VAC 50 Hz: 2.3 mA 1.2 mA from 10kHz to 1GHz Hipot rating (one minute): Available with an IEC inlet, fuseholder and switch Line to Ground: 2250 VDC Suitable for applications where computers are Line to Line: 1450 VDC used to process secret or condential information Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Ordering Information Rated Current: 3 or 6A 3 V AQ 8 FS Operating Ambient Temperature Range (at rated current I ): -10C to +40C r Sux In an ambient temperature (T ) higher than +40C a F Fuseholder the maximum operating current (I ) is calculated as o FS Fuseholder & Switch follows: I = I (85-Ta)/45 o r (F & FS on VAQ8 only) Electrical Schematics Omit if none 3A Models Input / Output Style LINE LOAD 3 Wire leads 8 IEC inlet* (line side) Wire leads (load side) 6A Models AQ Series LINE LOAD Leakage current designation V Standard Current Rating 3 or 6A Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Available Part Numbers 3VAQ3 6VAQ3 3VAQ8F 6VAQ8F 3VAQ8FS 6VAQ8FS *IEC 60320-1 C14 inlet mates with C13 connector 12 Dimensions are in inches and millimeters unless otherwise specied. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specications subject to change.RFI Power Line Filters Catalog: 1654001 Corcom Product Guide Issue Date: 06.2011 High Frequency Power Line Filter or Power Entry Module (continued) AQ Series Case Styles and Dimensions 3VAQ3 6VAQ3 1 1.66 .015 2.46 C 2.572 L C L 42.1 .38 62.3 65.3 5.126 12.0 Min. 4.14 12.0 Min. 130.0 304.8 105.1 304.8 5.327.015 (5 places) 4.36 .015 135.3 .515 111.4 .38 6-32 .515 13.08 (2 places) 6-32 Thd. 13.08 .5 .01 1.0 0.1 6-32 (2 x) 6-32 12.7 .25 25.4 .25 3.061 2.0 .01 1.98 77.8 50.8 .25 40.1 .78 .50 .02 12.7 .5 19.8 3VAQ8F 6VAQ8F 5.96 6.457 152.0 164 5.68 .01 5.06 .015 44.3 .25 128.6 .38 4.0 .01 102 .25 2.35 .015 .90 59.6 .38 22.9 2.328 .01 3.062 1.125 .01 59 .35 77.8 2.48 1.58 .015 28.6 .25 .958 63.0 40 .38 24.3 .355 6-32 .354 .010 .391 .01 ref ref (6) inserts 9.02 8.99 .25 9.93 .25 6-32 .411 ref (6) inserts 12.0 Min. 10.4 12.0 Min. 305.0 305.0 2.576 1.62 65.4 41.2 .375 .125 .375 .125 9.53 3.2 9.53 3.2 3VAQ8FS 6VAQ8FS 7.125 5.39 .015 181.0 .172 136.9 .38 1.058 6.347 .015 4.37 26.9 2.35 .015 161.2 .38 6-32 59.6 .38 4.0 .015 (6) inserts 101.55 .25 .44 11.2 2.48 1.575 .015 .958 63.0 2.33 .015 40.01 .38 3.07 24.3 1.52 .01 59.0 .38 77.8 38.5 .25 6-32 .411 ref (6) inserts .364 10.4 1.12 .01 .391 .01 .375 .125 9.25 28.3 .25 9.93 .25 9.53 3.2 12.0 Min. 1.62 304.8 41.2 2.58 65.4 6.30 12.0 Min375 .125 305.0 160.0 9.53 3.2 13 Dimensions are in inches and millimeters unless otherwise specied. Values in italics For email, phone or live chat, please go to te.com/help are metric equivalents. Dimensions are shown for reference purposes only. corcom.com Specications subject to change.