Surge arrester
2-electrode arrester
Series/Type: G30-A90XSMD
Ordering code: B88069X4103T203
Date: 2016-04-27
Version: 02
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color towhit. This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1 Surge arrester
(header 1 + top left bar):
Identification/Classification 2 2-electrode arrester
(header 2 + bottom left header bar):
Ordering code: (top right header bar) B88069X4103T203
Series/Type: (bottom right header bar)
G30-A90XSMD
Preliminary data (optional):
Department: PPD AB PD / PPD AB PM
Date: 2016-04-27
Version: 02
EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester B88069X4103T203
2-electrode arrester G30-A90XSMD
Features Applications
Very small size ESD protection
Very fast response time Applications with limited space
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Electrical specifications
1) 2)
DC spark-over voltage 90 V
Tolerance 20 %
Min. 72 V
Max. 108 V
Impulse spark-over voltage
at 100 V/s - for 99% of measured values < 400 V
- typical values of distribution < 300 V
at 1 kV/s - for 99% of measured values < 650 V
- typical values of distribution < 600 V
3)
Service life
300 operations 8/20 s 100 A
10 operations [5 (+) & 5 ()] 8/20 s 1 kA
1 operation 8/20 s 2 kA
4)
200 operations contact discharge 500 A
Insulation resistance at 50 V > 1
G
DC
Capacitance at 1 MHz < 0.5 pF
Arc voltage at 1 A ~ 10 V
Glow to arc transition current < 1.0 A
Glow voltage ~ 60 V
Weight ~ 0.2 g
Operation and storage temperature C
40 ... +125
Climatic category (IEC 60068-1) 40/125/21
Marking without
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
3)
Tests according to ITU-T Rec. K. 12 and UL 1449
4)
Contact discharge parameters: 1500 pF, 10 kV, 20
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
PPD AB PD / PPD AB PM 2016-04-27
Please read Cautions and warnings and Page 2 of 5