Surge arrester
2-electrode arrester
Series/Type: S50-A230X
Ordering code: B88069X1923T902
Version/Date: Issue 01 / 2012-11-09
Version: 01
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color towhit (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbolPrevie and thenClos. Please do not alter the header or
footer when copying the content.
Identification/Classification 1: Surge arrester
(header 1 + top left header bar)
Identification/Classification 2: 2-electrode arrester
(header 2 + bottom left header bar)
Ordering code: B88069X1923T902
(top right header bar)
Series/Type: S50-A230X
(top right header bar)
Preliminary data (optional):
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
(if necessary)
contained therein without EPCOS' prior express consent is prohibited.
Department: PPD AB PD / PPD AB PM
EPCOS AG is a TDK Group Company.
Date: Issue 01 / 2012-11-09
Surge arrester B88069X1923T902
2-electrode arrester S50-A230X
Features Applications
Very small size Modem
High current rating XDSL-splitter
Very fast response time Data lines
Stable performance over life Tuner
Very low capacitance Antenna
High insulation resistance
Excellent SMD handling
RoHS-compatible
Electrical specifications
1) 2)
DC spark-over voltage 230 V
%
20
Impulse spark-over voltage
at 100 V/s - for 99% of measured values < 550 V
- typical values of distribution < 500 V
at 1 kV/s - for 99% of measured values < 650 V
- typical values of distribution < 600 V
Service life
10 operations 50 Hz, 1 s 5 A
1 operation 50 Hz, 0.18 s (9 cycles) 10 A
10 operations 8/20 s 5 kA
3)
1 operation 8/20 s 10 kA
1 operation 10/350 s 0.5 kA
300 operations 10/1000 s 100 A
Insulation resistance at 100 V > 1
DC G
Capacitance at 1 MHz < 1 pF
Arc voltage at 1 A ~ 15 V
Glow to arc transition current ~ 0.8 A
Glow voltage ~ 60 V
Weight ~ 1 g
Operation and storage temperature -40 ... +90 C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking without
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
3)
After loading DC breakdown may exceed initial values but device will remain in a safe mode.
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
PPD AB PD / PPD AB PM Issue 01 / 2012-11-09
Please read Cautions and warnings and Page 2 of 4