Switching Power Supplies 75W +5.1/+24/-12/12V

Manufacturer: SL Power
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 159.7331 ea
Line Total: USD 159.73

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Wed. 29 May to Tue. 04 Jun

MOQ : 1
Multiples : 1

Stock Image

GLM75DG
SL Power

1 : USD 159.7331
10 : USD 140.1499
25 : USD 130.1312
50 : USD 121.4476
100 : USD 113.8634

0 - WHS 2


Ships to you between Wed. 29 May to Tue. 04 Jun

MOQ : 1
Multiples : 1

Stock Image

GLM75DG
SL Power

1 : USD 183.5874

0 - WHS 3


Ships to you between
Thu. 20 Jun to Wed. 10 Jul

MOQ : 1
Multiples : 1

Stock Image

GLM75DG
SL Power

1 : USD 259.2154

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Open Frame/Enclosed
Output Power
Input Voltage
Number of Outputs
Output Voltage-Channel 1
Output Voltage-Channel 2
Output Current-Channel 1
Output Current-Channel 2
Industry
Mounting Style
Length
Width
Height
Series
Approvals
Dimensions
Brand
Output Current-Channel 3
Output Voltage-Channel 3
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
GNT212G electronic component of SL Power GNT212G

Switching Power Supplies 200W 12V
Stock : 36

GNT218G electronic component of SL Power GNT218G

Switching Power Supplies 200W 18V
Stock : 24

GNT236G electronic component of SL Power GNT236G

Switching Power Supplies 200W 36V
Stock : 6

GNT248G electronic component of SL Power GNT248G

Switching Power Supplies 200W 48V
Stock : 26

GNT30-28G electronic component of SL Power GNT30-28G

AC/DC Power Supply Single-OUT 28V 1.07A 30W Medical 10-Pin
Stock : 0

GNT224G electronic component of SL Power GNT224G

Switching Power Supplies 200W 24V
Stock : 6

GNT30-48G electronic component of SL Power GNT30-48G

AC/DC Power Supply Single-OUT 48V 0.625A 30W Medical 11-Pin
Stock : 25

Image Description
GLS103-M electronic component of Sola GLS103-M

Switching Power Supplies 150W 12 V 8.3A
Stock : 0

GLS123 electronic component of Sola GLS123

Switching Power Supplies 120W 12V 6.6A
Stock : 0

GLS152 electronic component of Sola GLS152

Switching Power Supplies 150W 5V 22A
Stock : 0

GLS45 electronic component of Sola GLS45

Switching Power Supplies 40W 24V 1.6A
Stock : 0

GLS65 electronic component of Sola GLS65

Switching Power Supplies 60W 24V 2.5A
Stock : 0

GLT22 electronic component of Sola GLT22

Switching Power Supplies 60W Three channel 5V/12V/-12V
Stock : 19

GLT42 electronic component of Sola GLT42

Switching Power Supplies 40W Three channel 5V/12V/-12V
Stock : 0

GLT45 electronic component of Sola GLT45

Switching Power Supplies 40W Three channel 5V/15V/-15V
Stock : 1

GLX17Q-C electronic component of Sola GLX17Q-C

Switching Power Supplies Cover Kit for quad output GL170
Stock : 0

GLOBAL PERFORMANCE SWITCHERS GLC75 Commercial/GLM75 Medical 75 Watt Multiple Output Global Performance Switchers FEATURES: Cost-effective multiple output power source Universal input 90-264 Vac 7.00x 4.25x 1.30 (Meets 1U height) 2-year warranty Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) Complies with EN61000-3-2 Class A Also available in single output versions Commercial UL1950 3rd Edition, CSA22.2 No. 950 and EN60950-1 approvals Medical Approved to UL2601-1, CSA22.2 No. 601.1-M90, and IEC/EN60601-1 RoHS Compliant Model Available (G suffix) SPECIFICATIONS Efficiency Ac Input 68% -78% depending on model and load distribution. 90-264 Vac, 47-63 Hz single phase. Input Protection Input Current Internal ac fuse provided on all units. Designed to blow only if a catastrophic Maximum input current at 120 Vac, 60 Hz with full rated output load not to failure occurs in the unit. exceed 2.3 A. Inrush Current Output Power Inrush limited by internal thermistors. Inrush at 240 Vac, averaged over the first ac Normal continuous output power is 75 W for unrestricted natural convection half-cycle under cold start conditions will not exceed 37 A. cooling or 110 W with 26 cfm airflow. During peak load conditions output regulation may exceed total regulation and noise limits. Hold Up Time 20 ms minimum from loss of ac input power at full load, nominal line (120 Vac). Output Regulation Measured by 40% load change from 60% rated load with all other outputs Temperature Coefficient at 60% rated load and input voltage change from minimum to maximum rat- 0.03%/C typical on all outputs. ings. Output #1 requires 1A minimum load for proper regulation of other Power Fail outputs. Initial set tolerance is measured with all outputs at 60% of full rated A standard TTL or CMOS compatible output goes low (< 0.5 V) 5ms before output load. Output #2 requires 0.5A minimum load for proper regulation. voltage drops more than 4% below nominal voltage upon loss of ac power. Signal Overload Protection is factory set to trip on 84 to 94 Vac brown-out depending upon incoming line Factory set to begin power limiting at approximately 120 W. Fully protected impedance and distortion. Other settings are available through adjustment of against short circuit and output overload. Short circuit protection is cycling built-in potentiometer (consult factory for assistance). Output will stay low for 20 type power limit. ms minimum. Output Noise EMI/EMC Compliance 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with All models include built-in EMI lfi tering to meet the following emissions requirements: noise probe directly across output terminals of the power supply. EMI SPECIFICATIONS COMPLIANCE LEVEL Transient Response Main Output: 500Sec typical response time for return to within 0.5% of final Conducted Emissions GLC75 EN55022 Class B; FCC Class B value for a 50% load step change, i/t<0.2A/Sec. Maximum voltage devia - Conducted Emissions GLM75 EN55011 Class B: FCC Class B tion is 3.5%. Static Discharge EN61000-4-2, 6 kV contact, 8 kV air RF Field Susceptibility EN61000-4-3, 3 V/meter Overvoltage Protection Fast Transients/Bursts EN61000-4-4, 2 kV, 5 kHz Built in on V1 with firing point set per table. OVP firing reduces output #1 and Surge Susceptibility EN61000-4-5, 1 kV diff., 2 kV com. #2 to less than 50% of nominal voltage in 50 ms. Line Frequency Harmonics EN61000-3-2 Class A Voltage Adjust Commercial Safety Factory set on standard unit; however, optional potentiometer (-V suffix) All GLC models are approved to UL1950 3rd Edition, CSA22.2 No. 950, and adjusts voltage from 4.7 V to OVP point (6.2 V nominal) on the +5 V output. EN60950-1. Note: Output #1 must not be more than 1% below nominal to achieve full output voltage range on Output #2. Output regulation limits in some models Medical Leakage Current may be exceeded when the main output is adjusted beyond +1% of nominal 70 A 264 V @ 50 Hz (normal conditions). voltage. High voltage settings may degrade the reliability of the unit due to Medical Safety excessive power dissipation in some outputs. GLM models are approved to UL2601-1, CSA22.2 No. 601.1M90, IEC/EN60601-1. CB Report available. O All specifications are typical at nominal input, full load at 25 C unless otherwise statedCommercial Medical RoHS Output Output Output Output Output Model Model Suffix* No. Output Minimum Maximum (A) Maximum (B) Peak V1 OVP Set Noise P-P Regulation GLC75A GLM75A G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +12 V 0.5 A 2.5 A 3 A 4 A 120 mV +10%,-5% (D) 3 -12 V 0 A 1 A 1 A 1.2 A 120 mV 3% 4 +12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC75B GLM75B G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +12 V 0.5 A 2.5 A 3 A 4 A 120 mV +10%,-5% (D) 3 -5 V 0 A 1 A 1 A 1.2 A 50 mV 3% 4 +12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC75C GLM75C G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +12 V 0.5 A 2.5 A 3 A 4 A 120 mV +10%,-5% (D) 3 -15 V 0 A 1 A 1 A 1.2 A 150 mV 3% 4 +15 V 0 A 2.5 A 3 A 4 A 150 mV 2% GLC75D GLM75D G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +24 V 0.5 A 2.5 A 2.5 A 3.5 A 240 mv +10%,-5% (D) 3 -12 V 0 A 1 A 1 A 1.2 A 120 mV 3% 4 +12 V 0 A 2.5 A 3 A 4 A 120 mV 2% GLC75E GLM75E G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +24 V 0.5 A 2.5 A 2.5 A 3.5 A 240 mV +10%,-5% (D) 3 -15 V 0 A 1 A 1 A 1.2 A 150 mV 3% 4 +15 V 0 A 2.5 A 3 A 4 A 150 mV 2% GLC75F GLM75F G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +15 V 0.5 A 2.5 A 3 A 4 A 150 mV +10%,-5% (D) 3 -5 V 0 1 A 1 A 1.2 A 50 mV 3% 4 -15 V 0 2.5 A 3 A 4 A 150 mV 2% GLC75H GLM75H G 1 +5.1 V 1A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +15 V 0.5 A 2.5 A 3 A 4 A 150 mV +10%,-5% (D) 3 -15 V 0 1 A 1 A 1.2 A 150 mV 3% 4 +15 V 0 2.5 A 3 A 4 A 150 mV 2% GLC75J GLM75J G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +12 V 0.5 A 2.5 A 3 A 4 A 120 mV +10%,-5% (D) 3 -12 V 0 1 A 1 A 1.2 A 120 mV 3% 4(C) 5 V 0 2.0 A 3 A 4 A 50 mV 2% GLC75P GLM75P G 1 +5.1 V 1 A 8 A 10 A 12 A 6.2 0.6 V 50 mV 2% 2 +24 V 0.5 A 4 A 4 A 4.5 A 240 mv +10%,-5% (D) 3 -12 V 0 A 1 A 1 A 1.2 A 120 mV 3% 4 +12 V 0 A 2.5 A 3 A 4 A 120 mV 2% * Add G suffix to part number for RoHS compliant model. Contact factory for availability. A. Rating with unrestricted convection cooling. Total power not to exceed 75 W. B. Rating with 26 cfm forced-air cooling. Total power not to exceed 110 W. C. Floating fourth output can be referenced as either positive or negative. Connect pin 12 to Return to provide a positive voltage at Pin 13. Connect pin 13 to Return to provide a negative voltage at Pin 12. D. To maintain these regulations conditions, the +5V current must be at least 1/5 of V2 and not greater than 5 times the V2 current. Requires +5V to be adjusted to within 1% with at least a 1 A load to maintain regulation on this output. GLC75/GLM75 - MULTIPLE OUTPUT - MECHANICAL SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output current and total Temperature (A) 0 to 50 -40 to +85C output power by 2.5% per C above 50C. Humidity (A) 0 to 95% RH 0 to 95% RH B. Shock testinghalf-sinusoidal, 10 3 ms duration, direction, 3 Shock (B) 20 g 40 g orthogonal axes, total 6 shocks. pk pk Altitude -500 to 10,000 ft -500 to 40,000 ft C. Random vibration10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1 2 2 Vibration (C) 1.5 g 0.003 g /Hz 5 g 0.026 g /Hz rms rms hr./axis non-operating. SL Power Electronics, Inc., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 9-23-10. Data Sheet 2010 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.

Tariff Desc

8504.40.90 POWER SUPPLIES, having BOTH:
(a) input voltages of 176V-246VAC, 47Hz-63Hz single phase OR 200V-230VAC, 50Hz-60Hz single phase
(b) multiple DC output voltages from minus 200 V to positive 200V
TC 9603032

8504.40.90 CHARGERS, ADAPTERS AND INVERTERS, AC/DC OR DC/DC OR DC/AC having ALL of the following:
(a) input voltage NOT less than 10V and NOT greater than 252V
(b) output voltage NOT less than 2V and NOT greater than 252V
(c) wattage NOT less than 40 W and NOT greater than 160W
(d) output current NOT greater than 17A - TC 1021920

8504.50.10 81
(a) designed for use with equipment of 8471
(b) for telecommunication apparatus of 8517 Free

8504.40.90 POWER SUPPLY UNITS, DC AND/OR AC output, complying with AS/NZS 60950 & AS/NZS CISPR 22, having ALL of:
(a) voltage NOT less than 2.5 V and NOT greater than 55V
(b) wattage NOT less than 0.02 W and NOT greater than 105W
(c) current output NOT less than 0.01 amp and NOT greater than 2.5amp
TC 1014564

8504.40.90 POWER SUPPLY MODULES having ALL of the following:
(a) input power at EITHER of the following voltages:
(i) 120VAC/240VAC
(ii) 24VDC /48VDC
(b) output power at EITHER of the following voltages:
(i) 5VDC, +15VDC, -15VDC, and 24VDC field I/O
(ii) 24VDC field I/O only
(c) circuitry monitors
(d) output adjusters
TC 9810001

8504.40.90 POWER SUPPLIES DC having BOTH:
(a) variable voltage NOT exceeding 30V
(b) maximum current output NOT exceeding 25amps
TC 9900597

8504.40.90 CONVERTERS, DC/DC, power output not exceeding 5W, being ANY of:
(a) single in line package
(b) dual in line
(c) surface mount device
TC 9601650

8543.90.20 20 Electronic microassemblies Free

8504.40.30 Static converters
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 No Electric current rectifying assemblies Free
63 No Other Free
Ault SL Power
Ault / SL Power
Condor
Condor SL Power
Condor / SL Power
SL POWER
SL POWER / CONDOR
SL Power / Condor and Ault
SL Power / Condor&Ault
SL Power Electronics
SL Power Electronics Manufacture of Condor/Ault Brands
SL Power Electronics Manufacture of CondorAult Brands

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted