Product Information

3RV1011-0GA10

3RV1011-0GA10 electronic component of Siemens

Datasheet
Motor breaker; 0.18kW; 220÷690VAC; DIN; Short circ.release:8.2A

Manufacturer: Siemens
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 59.3229 ea
Line Total: USD 59.32

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Mon. 06 May to Fri. 10 May

MOQ : 1
Multiples : 1
1 : USD 61.4387

     
Manufacturer
Product Category
Electrical Connection
Mounting
Related Items
Type Of Protection
Max Motor Power
Range Of Overcurrent Release Settings
Short Circuit Release
Operating Voltage
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
3RV1011-0JA10 electronic component of Siemens 3RV1011-0JA10

Motor breaker; 0.25kW; 220÷690VAC; DIN; Short circ.release:13A
Stock : 13

3RV1011-1BA10 electronic component of Siemens 3RV1011-1BA10

Motor breaker; 0.75kW; 220÷690VAC; DIN; Short circ.release:26A
Stock : 37

3RV1011-1BA15 electronic component of Siemens 3RV1011-1BA15

Motor breaker; 0.75kW; Auxiliary contacts: NO + NC; 220÷690VAC
Stock : 4

3RV1011-1CA10 electronic component of Siemens 3RV1011-1CA10

Motor breaker; 0.75kW; 220÷690VAC; DIN; Short circ.release:33A
Stock : 38

3RV1011-1DA10 electronic component of Siemens 3RV1011-1DA10

Motor breaker; 1.1kW; 220÷690VAC; DIN; Short circ.release:42A
Stock : 8

3RV1011-1AA10 electronic component of Siemens 3RV1011-1AA10

Motor breaker; 0.55kW; 220÷690VAC; DIN; Short circ.release:21A
Stock : 69

3RV1011-1AA15 electronic component of Siemens 3RV1011-1AA15

Motor breaker; 0.55kW; Auxiliary contacts: NO + NC; 220÷690VAC
Stock : 5

3RV10110KA10 electronic component of Siemens 3RV10110KA10

3RV1 Motor Starter Protectors
Stock : 5

3RV1011-1DA15 electronic component of Siemens 3RV1011-1DA15

Motor breaker; 1.1kW; Auxiliary contacts: NO + NC; 220÷690VAC
Stock : 11

3RV1011-0HA10 electronic component of Siemens 3RV1011-0HA10

Motor breaker; 0.18kW; 220÷690VAC; DIN; Short circ.release:10A
Stock : 4

Image Description
3RV1011-0JA10 electronic component of Siemens 3RV1011-0JA10

Motor breaker; 0.25kW; 220÷690VAC; DIN; Short circ.release:13A
Stock : 13

3RV1011-1BA10 electronic component of Siemens 3RV1011-1BA10

Motor breaker; 0.75kW; 220÷690VAC; DIN; Short circ.release:26A
Stock : 37

3RV1011-1BA15 electronic component of Siemens 3RV1011-1BA15

Motor breaker; 0.75kW; Auxiliary contacts: NO + NC; 220÷690VAC
Stock : 4

3RV1011-1CA10 electronic component of Siemens 3RV1011-1CA10

Motor breaker; 0.75kW; 220÷690VAC; DIN; Short circ.release:33A
Stock : 38

3RV1011-1DA10 electronic component of Siemens 3RV1011-1DA10

Motor breaker; 1.1kW; 220÷690VAC; DIN; Short circ.release:42A
Stock : 8

3RV1011-1FA10 electronic component of Siemens 3RV1011-1FA10

Motor breaker; 1.5kW; 220÷690VAC; DIN; Short circ.release:65A
Stock : 40

3RV1011-1GA10 electronic component of Siemens 3RV1011-1GA10

Motor breaker; 2.2kW; 220÷690VAC; DIN; Short circ.release:82A
Stock : 13

3RV1913-1DA00 electronic component of Siemens 3RV1913-1DA00

Housing to SIRIUS breakers; Series: S00
Stock : 2

3RV2011-0EA10 electronic component of Siemens 3RV2011-0EA10

Motor breaker; 0.09kW; 220÷690VAC; DIN; Short circ.release:5.2A
Stock : 29

3RV2011-1BA10 electronic component of Siemens 3RV2011-1BA10

Motor breaker; 0.75kW; 220÷690VAC; DIN; Short circ.release:26A
Stock : 69

LV1 09 Gesamt EN.book Seite 1 Mittwoch, 11. Februar 2009 3:54 15 Siemens AG 2009 Protection Equipment 5 5/2 Introduction 3RV Circuit Breakers/Motor Starter Protectors up to 100 A 5/5 General data 5/7 For motor protection 5/11 For motor protection with overload relay function 5/12 For starter combinations 5/13 For transformer protection 5/14 For fuse monitoring 5/15 For system protection according to UL 489/CSA C22.2 No. 5-02 5/16 For transformer protection according to UL 489/CSA C22.2 No.5-02 5/17 For distance protection Accessories 5/18 Mountable accessories 5/22 Busbar accessories 5/25 Rotary operating mechanisms 5/27 Mounting accessories 5/31 Enclosures and front plates 3RV Molded Case Motor Starter Protectors up to 800 A 5/34 General data 5/35 For motor protection 5/36 For starter combinations Accessories 5/37 Mountable accessories 5/38 Rotary operating mechanisms Mounting accessories Overload Relays 5/39 General data 3RU1 Thermal Overload Relays 5/43 3RU11 for standard applications 5/47 Accessories 3RB2 Solid-State Overload Relays 5/48 3RB20, 3RB21 for standard applications 5/56 3RB22, 3RB23 for high-feature applications 5/60 Accessories Siemens LV 1 2009LV1 09 Gesamt EN.book Seite 2 Mittwoch, 11. Februar 2009 3:54 15 Siemens AG 2009 Protection Equipment Introduction Overview Type 3RV10 3RV11 3RV13 3RV14 3RV16 3RV16 3RV17 3RV18 3RV1 circuit breakers/motor starter protectors up to 100 A Uses 1) 1) System protection -- -- -- -- Motor protection -- -- -- -- -- -- -- Motor protection with -- -- -- -- -- -- -- overload relay function Starter combinations -- -- -- -- -- -- -- Transformer protection -- -- -- -- -- Fuse monitoring -- -- -- -- -- -- -- Voltage transformer -- -- -- -- -- -- -- circuit breakers for distance protection Size S00, S0, S2, S3 S0, S2, S3 S0, S2, S3 S0, S2 S00 S00 S0, S3 S0 Rated current I n Size S00 A to 12 -- -- -- 0.2 to 3 -- -- Size S0 A to 25 to 25 to 25 to 20 -- -- to 22 to 20 Size S2 A to 50 to 50 to 50 to 40 -- -- -- -- Size S3 A to 100 to 100 to 100 -- -- -- to 70 -- 2) 2) 2) 2) 2) Rated operational voltage V 690 AC 690 AC 690 AC 690 AC 690 AC 400 AC 690 AC 690 AC U acc. to IEC e 2 Rated frequency Hz 50/60 50/60 50/60 50/60 50/60 16 / ... 60 50/60 50/60 3 Trip class CLASS 10 CLASS 10 -- CLASS 10 -- -- -- -- CLASS 20 3) Thermal A 0.11 ... 0.16 0.11 ... 0.16 None 0.11 ... 0.16 0.2 1.4 ... 3 0.16 ... 70 0.16 ... 20 overload release to to to non- non- A 80 ... 100 80 ... 100 28 ... 40 adjustable adjustable Electronic trip units A multiple of the rated current 13 times 13 times 13 times 20 times 6 times 4 ... 7 times 13 times 20 times 4) 4) Short-circuit breaking kA 50/100 50/100 50/100 50/100 100 50 capacity I at 400 V AC cu Accessories For sizes S00 S0 S2 S3 S0 S2 S3 S0 S2 S3 S0 S2 S00 S00 S0, S3 S0 5) 5) Auxiliary switches Signal switch -- -- -- -- -- Undervoltage trip units -- -- -- Shunt trip units -- -- -- Isolator modules -- -- -- -- -- -- -- -- Insulated three-phase -- -- -- -- -- -- busbar systems Busbar adapters -- -- Door-coupling rotary -- -- -- operating mechanisms Remote motorized -- -- -- -- -- -- -- -- -- operating mechanisms Link modules -- -- Enclosures for surface -- -- -- -- -- mounting Enclosures for flush -- -- -- -- -- -- -- -- -- mounting Front plates -- -- Infeed system -- -- -- -- -- -- -- -- -- -- -- -- 1) For symmetrical loading of the three phases. Has this function or can use this accessory 2) 500 V AC with molded-plastic enclosure. -- Does not have this function or cannot use this accessory 3) For overload protection of the motors, appropriate overload relays must be used. 4) According to UL 489 - at 480 Y/277 V AC: for size S0 50 kA, for size S3 65 kA - at 480 V AC: for size S3 (10 A up to 30 A) 65 kA. 5) Only lateral auxiliary switches can be fitted. Siemens LV 1 2009 5/2 5

Tariff Desc

8536.49 TC 8532678 CONTACTORS, having BOTH of the following:
(a) normally closed main poles;
(b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V"

8536.49.00 TC 17103979 RELAYS, PRINTED CIRCUIT BOARD

8536.41 TC 8909066 RELAYS, having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following:
a height NOT exceeding 21.24 mm;
b height NOT exceeding 35 mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following:
a one, two or three contacts;
b maximum continuous contact current rating of NOT less than 15A;
c maximum contact voltage rating of NOT less than 380V;
d maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following:
a maximum switching current NOT exceeding 5A (AC or DC);
b switching voltage NOT exceeding 250V (AC or DC);
c body dimensions NOT exceeding 31mm x 36mm x 19mm

8536.49 TC 8633667 RELAYS, vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS, SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics:
a trip time NOT exceeding 5 s at 6 times full load current
b manual reset
c maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts


Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted