Panel Mount Datasheet GN3 Series Current ratings of 25 and 50 Amps Output voltage rating: 48-600 VAC Direct bond copper substrate LED input status indicator IP20 touch-safe cover Transient protection built-in UL508 endurance rating for enhanced reliability UL/CSA/TUV Approved, CE Compliant to EN60950-1 PRODUCT SELECTION Control Voltage 25A 50A 4-32 VDC GN325DLZ GN350DLZ 18-36 VAC GN325ELZ GN350ELZ 90-140 VAC GN325BLZ GN350BLZ 180-260 VAC GN325ALZ GN350ALZ AVAILABLE OPTIONS Control Voltage A: 180-260 VAC B: 90-140 VAC Switching Type D: 4-32 VDC R: Instantaneous Turn-on E: 18-36 VAC Series Z: Zero voltage Turn-on GN3 25 A L Z Snubber Option Rated Load Current L: No Snubber (48-600 VAC) 25: 25 Amps S: Snubber Included (48-530 VAC) 50: 50 Amps Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (1) Description 25A 50A Operating Voltage (47-400Hz) Vrms (2) 48-600 48-600 Transient Overvoltage Vpk, t=1 min. (3) 1200 1200 Static off-state dv/dt (V/sec, Ta=25C) (4) 500 500 Maximum Load Current Arms (5) 25 50 Minimum Load Current mArms 100 100 Maximum Off-State Leakage Current mArms (6)(7) 0.06 0.06 1 Cycle surge current (50Hz) 275 710 1 Cycle surge current (60Hz) 300 750 1 Second surge current (Apk. Ta=25C) 50/60 Hz 85 150 Forward Voltage Drop (Vpk Imax, Ta=25C) 1.35 1.35 2 I T (50Hz, 1/2 cycle) 380 2520 2 I T (60Hz, 1/2 cycle) 370 2320 Thermal Resistance Junction to baseplate (Rjb) C/W 0.24 0.12 HP Ratings at 120V / FLC Arms 0.75 / 6.4 1.5 / 12 HP Ratings at 240V / FLC Arms 1 / 4.2 3 / 9.6 HP Ratings at 480V / FLC Arms 3 / 4.8 7.5 / 11 HP Ratings at 600V / FLC Arms 5 / 6.1 10 / 11 Min/Max wire size 16/8 AWG 16/8 AWG Screw Torque Range in-lb/Nm 18-20 / 2.03-2.26 18-20 / 2.03-2.26 FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.Panel Mount Datasheet INPUT SPECIFICATIONS (1) Description GN3xxDx GN3xxEx GN3xxBx GN3xxAx Control Voltage Range 4.0-32 VDC 18-36 Vrms 90-140 Vrms 180-260 Vrms Minimum Turn-On Voltage 4.0 VDC 18 Vrms 90 Vrms 180 Vrms Must Turn-Off Voltage 1.0 VDC 2 Vrms 10 Vrms 10 Vrms Maximum input current 39 mA 20 mArms 16 mArms 16 mArms Minimum input current (for on-state) 24 mA 15 mArms 7 mArms 7 mArms Input Resistance Current Regulated Turn-On Time msec (8) 1/2 Cycle 20 20 20 Turn-Off Time msec 1/2 Cycle 30 30 30 Min/Max wire size 24/14 AWG Screw Torque Range in-lb/Nm 8-10 / 0.9-1.13 GENERAL SPECIFICATIONS Description Parameters Ambient Operating Temperature Range (9) -40C to 80C Ambient Storage Temperature Range -40C to 125C Input to output isolation 4000 Vrms Input/Output to ground isolation 2500 Vrms Input to output capacitance 8 pF Housing Material UL 94V0 (self extinguishing) Input Status Indicator Green LED Weight (typical) 0.79 oz (360 g) GENERAL NOTES 1) All parameters at 25C unless otherwise specied. 2) For part numbers with snubber Hz range is 47-63 and line voltage is 48-530VAC 3) Output will self trigger between 900-1200Vpk. 4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 5) When mounted to the proper size heat sink (see derating curves) 6) For part numbers with snubber maximum leakage current is 5mA. 7) Measured between 1/L1 and 2/T1 or 3/L2 and 4/T2 or 5/L3 and 6/T3 8) For DC control Instantaneous turn-on is 100 sec while for AC control is 20 msec 9) Operating temperature range for 180-280VAC is -20 to +60C MECHANICAL SPECIFICATIONS Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches millimeters 4.0 101.3 3.6 92.0 5/L3 3/L2 1/L1 1.87 47.6 3.2 79.7 0.2 5.1 6/T3 4/T2 2/T1 0.8 19.3 1.5 38.6 1.45 36.83 4.09 103.9 Do not forget to visit us at: www.crydom.com Copyright 2017Crydom Inc. Specifications subject to change without notice.