Product Information

DR10D03X

DR10D03X electronic component of Sensata

Datasheet
Solid State Relays - Industrial Mount SSR Relay, DIN Rail Mount 11mm, 100VDC/3A,4-32VDC In, FET Output, ATEX

Manufacturer: Sensata
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 66.846 ea
Line Total: USD 66.85

7 - Global Stock
Ships to you between
Wed. 29 May to Fri. 31 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
6 - WHS 1


Ships to you between Wed. 29 May to Fri. 31 May

MOQ : 1
Multiples : 1

Stock Image

DR10D03X
Sensata

1 : USD 61.6391
10 : USD 59.6695
50 : USD 56.9642
100 : USD 55.2794

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Series
Brand
Product Type
Factory Pack Quantity :
Subcategory
Hts Code
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
DR2220D20U electronic component of Sensata DR2220D20U

Solid State Relays - Industrial Mount 20A 4-32VDC 200VDC
Stock : 13

DR10D12X electronic component of Sensata DR10D12X

Solid State Relays - Industrial Mount SSR Relay, DIN Rail Mount 18mm, 100VDC/12A, 4-32VDC In, FET Output, ATEX
Stock : 4

DR10D12 electronic component of Sensata DR10D12

Solid State Relays - Industrial Mount 100VDC/12A 4-32VDC 18mm DR SSR
Stock : 26

DR10D06 electronic component of Sensata DR10D06

Solid State Relays - Industrial Mount 100VDC/6A 4-32VDC 11mm DR SSR
Stock : 0

DR10D06X electronic component of Sensata DR10D06X

Solid State Relays - Industrial Mount SSR Relay, DIN Rail Mount 11mm, 100VDC/6A,4-32VDC In, FET Output, ATEX
Stock : 17

DR2260A20VR electronic component of Sensata DR2260A20VR

Solid State Relays - Industrial Mount 20A 90-280VAC/DC 600VAC .5-3HP Std
Stock : 0

DR2260A20W electronic component of Sensata DR2260A20W

Solid State Relays - Industrial Mount 20A 90-280VAC/DC 600VAC .5-3HP Lug
Stock : 10

Image Description
DP4RSC60E60B2 electronic component of Sensata DP4RSC60E60B2

Contactors - Solid State PH DC H Bridge SS/B 48V 60A 32VCNT
Stock : 0

DP4RSC60E40B2 electronic component of Sensata DP4RSC60E40B2

Contactors - Solid State PH DC H Bridge SS/B 48V 40A 32VCNT
Stock : 0

DP4RSC60E40 electronic component of Sensata DP4RSC60E40

Contactors - Solid State PH DC H Bridge SS/SS 48V 40A 32VCNT
Stock : 3

DP4RSA60E40B8 electronic component of Sensata DP4RSA60E40B8

Contactors - Solid State PH DC H Bridge SS/B 48V 40A 32VCNT
Stock : 0

DP4RSA60E40B5 electronic component of Sensata DP4RSA60E40B5

Contactors - Solid State PH DC H Bridge SS/B 48V 40A 32VCNT
Stock : 0

DP4RSA60D40 electronic component of Sensata DP4RSA60D40

Contactors - Solid State PH DC H Bridge SS/SS 48V 40A 15VCNT
Stock : 0

DP4R60D60B5 electronic component of Sensata DP4R60D60B5

Contactors - Solid State PM DC H Bridge W/BRK 48V 60A 15VCNT
Stock : 0

DC60D10H electronic component of Sensata DC60D10H

Solid State Relays - Industrial Mount SSR Relay, Panel Mount, IP00, 60VDC/10A, 4-32VDC In, FET Output, Thermal Pad
Stock : 0

DC500F60 electronic component of Sensata DC500F60

Solid State Relays - Industrial Mount SSR Relay, Panel Mount, IP00, 500VDC/60A, 30-60VDC In, FET Output
Stock : 19

DIN Rail Mount DataSheet AC DC SeriesOne DR Series ATEX Ratings 3 Amps Load voltage ratings of 1-60 VDC, 1-100 VDC, 24-280 VAC and 48-600 VAC Fits standard 35mm DIN Rail LED input status indicator AC or DC control Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output UL 508 Endurance Rating for Enhanced Reliability UL Class I and II, Division 2, for Hazardous Locations PRODUCT SELECTION Control Voltage 280V, 3 A 600V, 3 A 60V, 3 A 100V, 3 A 4-32 VDC DR24D03X DR48D03X DR06D03X DR10D03X 90-140 VAC DR24B03X 200-280 VAC DR24A03X 18-36 VAC DR24E03X AVAILABLE OPTIONS Operating Voltage Switching Type Blank: Zero Voltage Turn-On 06: 1-60 VDC 10: 1-100 VDC (AC Output Only) Rated Load Current R: Instantaneous Turn-On 24: 24-280 VAC (AC Output) Series 48: 48-600 VAC 03: 3 Amps X R DR 06 D 03 Control Voltage Agency Approvals D: 4-32 VDC X: ATEX II 3G Ex nA IIC T4 Gc A: 200-265 VAC approved AC B: 90-140 VAC Output E: 18-36 VAC (1) Only Required for valid part number For options only and not required for valid part number (2) OUTPUT SPECIFICATIONS AC Output Description DR24x03X DR48x03X DR06D03X DR10D03X Operating Voltage (3) 24-280 Vrms 48-600 Vrms 1-60 VDC 1-100 VDC Transient Overvoltage Vpk 600 1200 N/A N/A Maximum Load Current, resistive (4) 3 Arms 3 Arms 3 3 Minimum Load Current 150 mArms 150 mArms 2.5 mAdc 2.5 mAdc Maximum Off-State Leakage Current Rated Voltage mA 0.1 0.1 0.1 0.1 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (5) 500 500 N/A N/A Maximum On-State Voltage Drop Rated Current Vpk 1.3 1.3 0.6 0.6 Maximum Surge Current (50/60Hz, 1 cycle) Apk 285/300 285/300 60 60 Maximum It for Fusing (50/60 Hz, 1/2 cycle) A sec 410/375 410/375 N/A N/A HP Rating UL 508/IEC60947 HP (KW) 240V 1/4 (.18) 1/4 (.18) N/A N/A HP Rating UL 508/IEC60947 HP (KW) 380V N/A 1/3 (.25) N/A N/A HP Rating UL 508/IEC60947 HP (KW) 480V N/A 1/2 (.37) N/A N/A Minimum Power Factor (at Maximum Load) 0.5 0.5 N/A N/A Min/Max stranded wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Min/Max solid wire 22/14 AWG 22/14 AWG 22/14 AWG 22/14 AWG Weight (Typical) 1.76 oz. (50g) 1.76 oz. (50g) 1.76 oz. (50g) 1.76 oz. (50g) Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount DataSheet (2) INPUT SPECIFICATIONS Description DRxxDxxX DRxxBxxX DRxxAxxX DRxxExxX Control Voltage Range (6) 4-32 VDC 90-140 Vrms 200-265 Vrms 18-36 Vrms (1) Minimum Turn-On Voltage 4.0 VDC 90 Vrms 200 Vrms 18 Vrms Must Turn-Off Voltage 1.0 VDC 40 Vrms 4 Vrms 10 Vrms Minimum Input Current for mA (7) 9 3 2.5 3.5 Maximum Input Current for mA (7) 11 5 3.3 8 Maximum Turn-on Time msec (8) (9) 1/2 Cycle 20 msec 20 msec 20 msec 1/2 Cycle 30 msec 30 msec Maximum Turn-off Time msec (10) 30 msec Min/Max stranded/solid wire 22/16 AWG 22/16 AWG 22/16 AWG 22/16 AWG (1) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms (11) 9 10 Ohm Minimum Insulation Resistance ( 500 VDC) Maximum Capacitance, Input/Output 10 pF Ambient Operating Temperature Range -20 to 40 C Ambient Storage Temperature Range -30 to 100 C Recommended Terminal Screw Torque Range 4.4-7.0 in-lb (0.5-0.8Nm) GENERAL NOTES (1) E option is UL certied for AC control voltage, but it works also with 18-36 VDC input range. (2) All parameters at 25C unless otherwise specied. (3) For AC output frequency is 47-63Hz (4) See Derating curves (5) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 (6) DC control includes reverse polarity protection. (7) Input circuitry incorporates active current limiter. (8) Turn-on time for DC control random turn-on versions is 0.1 msec. (9) Turn-on time for DC output 600sec. (10) Turn-off time for DC output 300sec. (11) 2500 Vrms for DC output. Standards of Compliance IEC 62314 LC A, Resistive or Slightly Inductive Load Ratings: 3 A 40C ambient for DR24x03X, 3 A 40C ambient for DR48x03X LC B, Motor Loads Ratings: 0.18KW 240VAC for DR24x03X and 0.375KW 480 VAC DR48x13X Shock and Vibration (Applies to all part numbers) Vibration Resistence according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz Shock Resistance according to IEC 60068-2-27: 15g/11ms EMC (Applies to all part numbers) IEC 61000-4-2: Electrostatic Discharge- Level 3 IEC 61000-4-4: Electrically Fast Transients- Level 3 IEC 61000-4-5: Electrical Surges- Level 3 ANSI / ISA 12.12.01-2013 Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classied) locations This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations WARNING-Explosion Hazard- Substitution of any component may impair suitability for class I, Division 2 ATEX Compliance with Essential Health and Safety Requirements has been assessed by reference to Standards EN 60079-0:2012+A11:2013 and EN 60079-15-:2010 Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.

Tariff Desc

8536.49.00 RELAYS, solid state, having an operating voltage NOT exceeding
600 V AC or 300 V DC, but NOT including protective monitoring TC 9320885

ELECTRICAL APPARATUS FOR SWITCHING OR PROTECTING ELECTRICAL CIRCUITS, OR FOR MAKING CONNECTIONS TO OR IN ELECTRICAL CIRCUITS FOR EXAMPLE, SWITCHES, RELAYS.
Airpax
AIRPAX / SENSATA
AIRPAX THERMAL
BEI Sensors
BEI SENSORS / SENSATA
BEI Sensors/Sensata
C3 COMPONENTS
CRY
Crydom
Crydom Co.
Cynergy 3
Cynergy 3 Components
Cynergy3
Kavlico
Kavlico/Sensata
Sensata / AIRPAX
Sensata / BEI Sensors
Sensata / Crydom
Sensata / Kavlico
SENSATA AIRPAX
Sensata Pressure & Temp
SENSATA TECHNOLOGIES
Sensata Technologies/Airpax
Sensata TechnologiesAirpax
SENSATA/CRYDOM
SENSATA/CYNERGY3
Sensata-Airpax
Sensata-Crydom
Thomson Airpax
Wells CTI

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted