Panel Mount DataSheet 53TP Series IP00 Three-phase solid-state relay Ratings 25 A, 50 A per phase 48-530 VAC 2 package styles IP00 or IP20 (See IP20 spec sheet for more information) SCR output for heavy industrial loads Transient protection built in AC or DC control Zero-crossing (resistive loads) or random-fire (inductive loads) output LED input status indicator UL Recognized, CE Compliant to EN60950-1 PRODUCT SELECTION Control Voltage 25 A 50 A 90-280 VAC A53TP25D A53TP50D 4-32 VDC D53TP25D D53TP50D AVAILABLE OPTIONS Load Current Switching Mode 25: 25 Amps Blank: Zero Voltage Turn-On Series 50: 50 Amps -10: Random Turn-On A 53TP 25 D H -10 Control Voltage Thermal Pad D: DC (4-32V) Blank: Not Included A: AC (90-280V) H: Included Required for valid part number For options only and not required for valid part number (1) OUTPUT SPECIFICATIONS AC Output Description 25 A 50 A Operating Voltage (47-63Hz) Vrms per UL-508 48-530 48-530 Nominal Voltage (47-63Hz) Vrms per EN 62314 480 480 Transient Overvoltage Vpk (2) 1200 1200 Maximum Off-State Leakage Current Rated Voltage mArms 10 10 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (3) 500 500 Maximum Load Current Arms (4) 25 50 Minimum Load Current Arms 0.05 0.05 Maximum Surge Current 50-60 Hz (16.6ms) Apk 239/250 597/625 Maximum On-State Voltage Drop Rated Current Vpk 1.6 1.6 Thermal Resistance Junction to Case (Rjc) C/W 1.02 0.63 Maximum It for Fusing 50-60 Hz (8.3 msec) A sec 285/260 1779/1620 Minimum Power Factor (with Maximum Load) 0.5 0.5 FDE-07-01 REV. A Do not forget to visit us at: www.crydom.com Copyright 2021 Crydom Inc. Specifications subject to change without notice.Panel Mount DataSheet (1) INPUT SPECIFICATIONS Description D53 A53 Control Voltage Range 4-32 VDC 90-280 Vrms Minimum Turn-On Voltage 4.0 VDC 90 Vrms Minimum Turn-Off Voltage 1.0 VDC 10 Vrms Minimum Input Current (for on-state) 19 mA 4V 2.2 mA 120V Maximum Input Current 25 mA 32V 10mA 240V Nominal Input Impedance Current Limiter Current Limiter Maximum Turn-On Time msec (5) 1/2 Cycle 50 Maximum Turn-Off Time msec 1/2 Cycle 50 (1) GENERAL SPECIFICATIONS Description Parameters Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms 9 Minimum Insulation Resistance ( 500 V DC) 10 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40C to 80C Ambient Storage Temperature Range -40C to 125C Weight (typical) 10.3 oz (315g) Encapsulation Thermally conductive Epoxy Terminals Nickel plated Brass Screws and Saddle clamps Zinc plated Steel Input Terminal Screw Torque Range: in lbs/Nm 8-10 / 0.9-1.1 Output Terminal Screw Torque Range: in lbs/Nm 15-20 / 1.7-2.2 GENERAL NOTES 1) All parameters at 25C unless otherwise specied. 2) Relay will self trigger between 900-1200 Vpk. 3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 4) Heat sinking required, see page 4 for derating curves. 5) Turn-on time for Random turn-on versions is 0.02 msec (DC Control Models) Do not forget to visit us at: www.crydom.com Copyright 2021 Crydom Inc. Specifications subject to change without notice.