Product data sheet XMLPM09BM71F Characteristics pressure transmitter - XMLP - -1+9bar - G1/4A male - 0..10V - M12 - set of 1 Main Range of product OsiSense XM Product or component Electronic pressure sensors type Pressure sensor type Pressure transmitter Pressure sensor name XMLP Electrical circuit type Control circuit Pressure sensor size -1...9 bar Local display Without Controlled fluid Air -30...135 C Fresh water 0...135 C Hydraulic oil -30...135 C Gas -30...135 C Refrigeration fluid -30...135 C Fluid connection type G 1/4A (male) conforming to DIN 3852-E Electrical connection 1 male connector M12 4 pins Us rated supply volt- 24 V DC SELV, voltage limits: 12...33 V age Current consumption < 7 mA Type of output signal Analogue Analogue output func- 0...10 V, 3-wire tion Quantity per set Set of 1 Type of packing Individual Complementary Pressure setting range -1...9 bar Maximum permissible accidental pressure 30 bar Destruction pressure 60 bar Materials in contact with fluid Stainless steel AISI 316L Fluorocarbon FPM Operating position Any position Protection type Load short-circuit Reverse polarity Electromagnetic compatibility 1.2/50 s shock waves immunity test conforming to EN/IEC 61000-4-5 - test level 1 kV (f = 42 Ohm) Immunity to magnetic fields conforming to EN/IEC 61000-4-8 - test level 100 A/m (f = 50 Hz) Susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3 - test lev- el 10 V/m (f = 80...3000 MHz) Radiated RF fields conforming to EN/IEC 61000-4-6 - test level 10 V (f = 0.01...80 MHz) Electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4 - test level 2 kV Electrostatic discharge immunity test conforming to EN/IEC 61000-4-2 - test level 8 kV air, 4 kV contact Uimp rated impulse withstand voltage 0.5 kV Response time on output <= 2 ms for 10...90 % of full scale Measurement accuracy +/- 0.5 % of the measuring range Accuracy 0.1 % of the measuring range Drift of the sensitivity +/- 0.02 % of measuring range/K Drift of the zero point +/- 0.02 % of measuring range/K Mechanical durability >= 10000000 cycles Nov 10, 2017 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.Product weight 0.09 kg Diameter 26 mm Length 38.1 mm Environment Standards EN/IEC 61326-2-3 NSF ANSI 61 Product certifications EAC CE CULus RCM Protective treatment TC Ambient air temperature for operation -30...85 C Ambient air temperature for storage -50...100 C Vibration resistance 20 gn (f = 15...2000 Hz) conforming to EN/IEC 60068-2-6 Shock resistance 100 gn for 11 ms conforming to EN/IEC 60068-2-27 IP degree of protection IP69K conforming to EN/IEC 60529 IP65 conforming to EN/IEC 60529 IP67 conforming to EN/IEC 60529 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1723 - Schneider Electric declaration of conformi- ty Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Product environmental profile Available Product end of life instructions Need no specific recycling operations 2