C C S S O O R R w E E M M T T P P R R a L L R I I E E A A r V V N N A N N T T r 3kVDC isolation Features DIP24 low profile package DC/DC Converter UL94V-0 package material Short circuit protected Regulated IEC/EN60950-1 certified Converters Dual outputs from a single supply RW-D Description 3 Watt 3 The RW-D series with 2:1 input voltage ranges and maximum height of 7.0 mm has been designed for DIP24 industrial automation markets where a dual output rail needs to be generated from a single rail source. The converters supply the full 3 Watts without additional heat-sinks over the temperature range -40C Dual Output to +85C. Selection Guide Part nom. Input Output Output Efficiency max. Capacitive (1) (2) Number Voltage Voltage Current typ. Load VDC VDC mA % F RW-0505D 4.5-9 5 300 71 2200 RW-0509D 4.5-9 9 167 73 1000 RW-0512D 4.5-9 12 125 74 1000 22++ RoHSRoHS REACHREACH RW-0515D 4.5-9 15 100 75 1000 compliantcompliant compliantcompliant 10 from 1010 from 10 RW-1205D 9-18 5 300 76 2200 RW-1209D 9-18 9 167 80 1000 IEC/EN60950-1 certified RW-1212D 9-18 12 125 83 1000 EN55032 compliant RW-1215D 9-18 15 100 83 1000 RW-2405D 18-36 5 300 78 2200 RW-2409D 18-36 9 167 81 1000 RW-2412D 18-36 12 125 85 1000 RW-2415D 18-36 15 100 85 1000 RW-4805D 36-72 5 300 78 2200 RW-4809D 36-72 9 167 82 1000 RW-4812D 36-72 12 125 84 1000 RW-4815D 36-72 15 100 84 1000 Notes: Note1: Efficiency is tested at nominal input and full load at +25C ambient Note2: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage on the converter Model Numbering RW- D Dual nom. Input Voltage Output Voltage Ordering Examples: RW-0505D 4.5-9Vin 5Vout Dual RW-1212D 9-18Vin 12Vout Dual RW-2415D 18-36Vin 15Vout Dual www.recom-power.com REV.: 2/2020 ECO-1 O O P P E a C C R R O O Y M M n D D O O U U t C C C C E E y T T R R S SRW-D DC/DC Converter Series Specifications (measured Ta= 25C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. 5VDC 4.5VDC 9VDC 12VDC 9VDC 18VDC Input Voltage Range nom. Vin= 24VDC 18VDC 36VDC 48VDC 36VDC 72VDC (3) Minimum Load 10% 100kHz 150kHz Internal Operating Frequency (4) Output Ripple and Noise 20MHz BW 50mVp-p Notes: Note3: Operation below 10% load won t harm the converter, but specifications may not be met Note4: Measurements are made with a 0.1F MLCC across output. (low ESR) Efficiency vs. Load RW-xx15D 100 90 80 70 60 50 40 30 20 2415D 4815D 10 0 0 10 20 30 40 50 60 70 80 90 100 Output Load % REGULATIONS Parameter Condition Value Output Accuracy 1.0% typ. / 2.0% max Line Regulation 0.1% typ. / 0.2% max. Load Regulation 10% to 100% load 0.2% typ. / 0.5% max. PROTECTIONS Parameter Type Value Short Circuit Protection below 100mW continuous, auto recovery tested for 1 second 3kVDC (5) Isolation Voltage rated for 1 minute 1.5kVAC/60Hz Isolation Resistance 1GW min. Isolation Capacitance 20pF min. / 40pF typ. / 60pF max. Insulation Grade functional Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note6: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type www.recom-power.com REV.: 2/2020 ECO-2 Efficiency %