PSM500 WWW.PHIHONG.COM PSM500 500W 1U RPS and Bulk n+1 With Active PFC Features SELV Output with 1500 VAC Diagnostics Isolation 500 Watts X 3 in 1U 19 Rack Full Protection OCP, OVP, OTP Hot Plug N+1 85-256V AC with Active PFC Applications Power Over Ethernet Network Redundant Power Source Telecommunications Servers Safety Approvals cUL/UL TUV CE Mechanical Characteristics Length: 300mm (11.81in) Height: 41mm (1.61in) Width: 107mm (4.21in) Weight: 1.8Kg (4lb.) Output Specifications Load Ripple (1) Regulation DC Output Model P-P (max) Voltage Min. Max. Line Load 50V (Main) 0A 10A PSM500-210 1% 0.5V 12V (Standby) 0A 1.5A 56V (Main) 0A 9A PSM500-216 1% 0.5V 12V (Standby) 0A 1.5A Note: (1) Measured with by-pass capacitors 0.1uf/10uf at output connector terminal and oscilloscope set at 20Mhz. Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com/ for the most up-to-date specifications and contact information. Revised 8/1/2017 PSM500 Characteristics WWW.PHIHONG.COM INPUT: EMC FCC Class B AC Input Voltage Range EN55022 conducted Class B *with external 85 to 264VAC filter (*measured with Y capacitors 0.01uf/400Vat main output connector terminal AC Input Current from V to unit chassis) 6A (RMS) maximum for 115VAC EN55022 conducted Class B radiated Class A 3A (RMS) maximum for 230VAC (using 3 x PSM500-210, or -216 in rack PSA1554-605) AC Input Line Fuse 10A/ 250V Isolation Test Primary to Secondary: 4242V DC Leakage Current Primary to Field Ground: 2121V DC 3.5mA maximum 254VAC 60Hz Output to Field Ground: 2121 V DC AC Input Frequency Immunity 47-63Hz ESD: EN61000-4-2. Level 3 RS: EN61000-4-3. Level 3 AC Inrush Current EFT: EN61000-4-4. Level 2 30A (RMS) maximum for 115VAC Surge: EN61000-4-5. Level 3 60A (RMS) maximum for 230VAC CS: EN61000-4-6. Level 3 Voltage Dips EN61000-4-11 OUTPUT: Harmonic: EN61000-3-2 Efficiency 83% (typical) at maximum load, and FEATURE: 115VAC/230VAC Front Panel LED DC Good, Fault condition Hold-up Time 10mS min. 120VAC and maximum load 50V Enable/Disable Non latching remote on/off pin Over Voltage Protection OV set at 57~60V non-latching Thermal Shutdown Non-Latching Over Current Protection Protection against short circuit. Isc max 110%- Fan Fail 140% full load current. The 50V, 56V can Latching operate in current mode till short circuit and can be shorted permanently without damage. Load Sharing 10% at full load ENVIRONMENTAL: Isolated diode Temperature Internal ORing Diode Located on main (-) Operation 0 to +50C output section Non-operation -30 to +70C Humidity 8 to 90% Output Connector Molex p/n 15060141 or equivalent Molex p/n 15249144 or equivalent (mating)