WWW.PHIHONG.COM 18 Watt Universal 3-Wire Input Adapter PSAA18U Adapter Meets EISA and Ecodesign Requirements Features Low Cost Non-vented/Spill-proof Case Efficiency Level V Compliance Low Profile Design Ecodesign ErP Directive 2009/125/EC Class B EMI level 2 annex 1b Compliant Applications Portable Equipment Peripherals Access Devices Network Hubs Safety Approvals cUL/UL CE Mechanical Characteristics Length: 103mm (4.06in) Height: 33.5mm (1.32in) Width: 49mm (1.93in) Weight: 140g (4.94oz.) Output Specifications (1) Load Ripple Regulation Efficiency DC Output Model Voltage Min. Max. P-P (max.) Line & Load Level PSAA18U-090 +9V 0A 2.0A 110mV 5% PSAA18U-120 +12V 0A 1.5A 120mV 5% PSAA18U-150 +15V 0A 1.2A 150mV 5% PSAA18U-240 +24V 0A 0.75A 240mV 5% (1) Measured after 10 minutes warm up at 25C with 12-inch twisted pair terminated with a 10uF capacitor and 0.1uF ceramic in parallel. Phihong is not responsible for any error, and reserves the right to make changes without notice. Please visit our website at www.phihong.com for the most up-to-date specifications and contact information. Revision 11/21/2011 PSAA18U Characteristics WWW.PHIHONG.COM Input: Short-Circuit Protection Output can be shorted permanently without damage AC Input Voltage Rating 100 to 240V AC Environmental: AC Input Voltage Range Temperature 90 to 264V AC Operation 0 to +40C Non-operation -20 to +75C Relative Humidity 0 to 90% AC Input Frequency 47 to 63Hz Emissions FCC Class B Input Current EN55022 Class B/CISPR22 Class B 0.6A (RMS) maximum at 100V AC 0.3A (RMS) maximum at 240V AC Immunity EN50082-1: (EN55024) Leakage Current EN61000-4-2 Level 4 0.25mA maximum at 250V AC and 50Hz EN61000-4-3 Level 2 EN61000-4-4 Level 2 Inrush Current EN61000-4-5 Level 3 60A for 100V Ac at maximum load EN61000-4-6 Level 2 150A for 240V AC at maximum load EN61000-4-8 Level 1 (Cold start at ambient 25C) EN61000-4-11 Input Power Saving Insulation Resistance 0.3W maximum at no load Input to Output : > 10M ohm, 500V DC Input to Field Ground: > 10M ohm, 500V DC Output: Efficiency Dielectric Withstand (Hi-pot) Test 80.3% average efficiency Primary to Secondary: 3000V AC for 1 min., 10mA Compliant for Level V Marking Primary to F.G.: 1500V AC for 1 min., 10mA Over-Voltage Protection Input Connector Auto restart IEC C14 Over-Current Protection DC Output Connector Auto restart 2.1mm x 5.5mm center positive standard Dimension Diagram Unit: mm Type text