For Gas Head-separated Dual Display Digital Pressure Sensor 699 DPS-400 SERIES DPH-100 SERIES General terms and conditions ........... F-17 Sensor selection guide ................. P.661~ FIBER Related Information SENSORS Glossary of terms ........................ P.1373~ General precautions ...................... P.1405 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT panasonic-electric-works.net/sunx Digital SENSORS STATIC CONTROL DEVICES Thin body controller can do cascade connection and ENDOSCOPE communication with upper devices LASER MARKERS PLC / TERMINALS Works like a fiber sensor HUMAN MACHINE DPS-400 series accommodates to the requirements for pressure sensors at production site such as miniaturization of INTERFACES sensors for downsizing equipment, convenient shape to fit into machines, and reduction of man-hours when it comes ENERGY CONSUMPTION VISUALIZATION to replacement. COMPONENTS Sensor head DPH-100 series Controller DPS-400 series FA COMPONENTS Direct installation using a Thin body (t10 mm t0.394 MACHINE VISION SYSTEMS hexagonal wrench in) and multi-unit connection on a DIN rail helps to UV CURING SYSTEMS downsize equipment for better Direct mounting from above construction. Installation in narrow spaces Extended freedom of layout Single axis type free turning Selection Guide structure Pressure/ Digital Display Pressure/ Head-separated Install on a DIN rail Flow Other Products Current value and threshold value can be checked simultaneously on the dual display The controller is equipped with a 4-digit dual digital display. Because the threshold value can be adjusted while DPC-L100/ DPH-L100 checking the current value (current pressure value), direct setting and checking of the threshold value is made DPS-400/ smoothly without having to switch screen modes. DPH-100 DPC-100/ DPH-100 Dual display + Direct setting DP5/DPH Because direct setting is possible Operation Thickness is as easy 10 mm 0.394 in as analog Threshold value Current value The current value and the threshold value can be checked simultaneously Head-separated Dual Display Digital Pressure Sensor DPS-400 SERIES DPH-100 SERIES 700 Wire-saving, space-saving FIBER SENSORS The quick-connection cables enable reductions in wiring. The connections and man-hours for the relay terminal block LASER SENSORS setup can be reduced and valuable space is saved. Also, DPS-400 series can be connected side-by-side with fiber sensors FX-300 series or laser sensors LS series. PHOTOELECTRIC SENSORS Wire-saving in power supply MICRO PHOTOELECTRIC SENSORS AREA Fiber sensor DPS-400 series DPS-400 series SENSORS FX-300 series LIGHT CURTAINS PRESSURE / FLOW Up to 16 sensors allowed in optical communication / setting copying SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Wire-saving in power supply* SIMPLE WIRE-SAVING DPS-400, FX-300, LS-400, etc. UNITS WIRE-SAVING Up to 16 sensors can be connected togetther SYSTEMS MEASUREMENT Output line 2 Output line 2 Output line 16 Output line 16 Output line 1 Power Output line 3 Output line 3 SENSORS supply cable STATIC CONTROL Main cable CN-74-C Sub cable CN-72-C DEVICES Only output lines are used, so that wiring can be greatly reduced and space saving can be obtained. Optical communication / setting copying ENDOSCOPE * Check the instruction manual of each model for the arrangement order and such when connecting, as communication varies depending on the model. LASER MARKERS PLC / Network communication Ultra high-speed response time at 150 s TERMINALS HUMAN MACHINE Connection to CC-Link open network is possible Ultra high-speed response time contributes to even INTERFACES through the communication unit for CC-Link SC-GU2-C. greater productivity. ENERGY CONSUMPTION Monitoring or setting changes can be carried out via a VISUALIZATION COMPONENTS PLC, PC, etc. Response time at 150 s FA COMPONENTS Object A Object B Object C MACHINE VISION SYSTEMS Threshold value Current pressure value Independent dual outputs and five output modes equipped UV CURING SYSTEMS The sensor is equipped with two independent comparative outputs in which separate sensing modes can be selected. Selection EASY mode Guide Pressure/ This mode is used for comparative output ON / OFF control. Digital Display Pressure/ Hysteresis mode Head-separated Flow Configure sensor settings to each object This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON / OFF control. Other Products through communications Window comparator mode by remote commands DPC-L100/ This mode is used for setting comparative output ON or OFF DPH-L100 at pressures within the setting range. DPS-400/ DPH-100 Forced output ON mode DPC-100/ DPH-100 The comparative outputs are forcibly maintained at ON DP5/DPH irrespective of the set values. Forced output OFF mode The comparative outputs are forcibly maintained at OFF irrespective of the set values.