CM6100 2 Channel Very Low Capacitance ESD Protection Device in CSP Product Description CM6100 ELECTRICAL SPECIFICATIONS AND CONDITIONS Table 2. PARAMETERS AND OPERATING CONDITIONS Parameter Rating Units Storage Temperature Range 55 to +150 C Operating Temperature Range 40 to +85 C Table 3. ELECTRICAL OPERATING CHARACTERISTICS (Note 1) Symbol Parameter Conditions Min Typ Max Units V Input Operating Supply Voltage 3.0 5.5 V IN V Breakdown Voltage (Positive) I = 8 mA 6 V B F I Channel Leakage Current V = 3 V 0.1 0.30 A LEAK IN C Channel Input Capacitance At 1 MHz, V = 0 V 1.5 pF IN IN C Channel Input Capacitance Matching At 1 MHz, V = 0 V 0.02 pF IN IN V ESD Protection Peak Discharge Voltage at any (Note 2) kV ESD channel input a) Contact Discharge per IEC 6100042 8 standard b) Air Discharge per IEC 6100042 standard 15 V Channel Clamp Voltage V I = 1 A, t = 8/20 s CL PP P Positive Transients +9.8 Negative Transients 1.5 R Dynamic Resistance I = 1 A, t = 8/20 s DYN PP P Positive Transients Any I/O pin to Ground 0.7 Negative Transients 0.5 1. All parameters specified at T = 25C unless otherwise noted. A 2. Standard IEC 6100042 with C = 150 pF, R = 330 . Discharge Discharge