G3DZ Solid State Relays SSR Identical to the G6D in Size with AC/DC dual-use type and DC-only Type Available for the Whole Product Line 10-A current leakage max. between open output terminals. 2,500-VAC dielectric strength ensured between input and output terminals. With or without input resistor incorporated models available. Incorporated with overvoltage absorption circuit (models with AC/DC output only). Full-wave rectified and half-wave rectified AC current switchable (excluding G3DZ-DZ02P(G)). Standard models are available with UL and CSA certification. RoHS Compliant Refer toSolid State Relays Common Precaution. Model Number Legend G 3 G3DZ- D 12 345 Z 1. Rated Load Power 2. Rated Load Current 3. Terminal Type 5. Input Resistance Supply Voltage R5 : 0.5 A P: PCB terminals None: With input 1 : 125 VAC R6 : 0.6 A resistance 4. Zero Cross Function (For AC/DC 2 : 240 VAC 02 : 2 A G : Without input dual-use type only) DZ : 24 VDC resistance L: Not equipped with zero cross function List of Models With Input Resistance Isolation Zero cross function Indicator Rated output load Rated input voltage Model Minimum packing unit 5 VDC 0.6 A 5 to 240 VAC 12 VDC G3DZ-2R6PL 5 to 100 VDC 24 VDC 5 VDC 0.5 A Photo-voltage No No 5 to 100 VAC 12 VDC G3DZ-1R5PL 25 pcs coupler 5 to 100 VDC 24 VDC 5 VDC 2.0 A 12 VDC G3DZ-DZ02P 5 to 24 VDC 24 VDC Without Input Resistance Isolation Zero cross function Indicator Rated output load Max. input current Model Minimum packing unit 0.5 A 3 to 125 VAC G3DZ-1R5PLG Photo-voltage 3 to 125 VDC No No 50 mA (DC input) 25 pcs coupler 2.0 A G3DZ-DZ02PG 3 to 26.4 VDC Connecting Socket Applicable Relay Model G3DZ- P6D-04P 1G3DZ Solid State Relays Ratings With Input Resistance Item Input Output Voltage level Rated Rated load Load voltage Operating voltage Impedance Load current * Inrush current Must operate Must release voltage voltage range Model voltage voltage 5 VDC 4 to 6 VDC 830 20% 4 VDC max. 5 to 240 VAC 3 to 264 VAC AC: 100 to 0.6 A G3DZ-2R6PL 12 VDC 9.6 to 14.4 VDC 2 k 20% 9.6 VDC max. 6 A (10 ms) 5 to 100 VDC 3 to 125 VDC DC: 10 to 0.6 A 24 VDC 19.2 to 28.8 VDC 4 k 20% 19.2 VDC max. 5 VDC 4 to 6 VDC 750 20% 4 VDC max. 5 to 100 VAC 3 to 125 VAC AC: 100 to 0.5 A G3DZ-1R5PL 12 VDC 9.6 to 14.4 VDC 2 k 20% 9.6 VDC max. 1 VDC min. 5 A (10 ms) 5 to 100 VDC 3 to 125 VDC DC: 10 to 0.5 A 24 VDC 19.2 to 28.8 VDC 4 k 20% 19.2 VDC max. 5 VDC 4 to 6 VDC 750 20% 4 VDC max. G3DZ-DZ02P 12 VDC 9.6 to 14.4 VDC 2 k 20% 9.6 VDC max. 5 to 24 VDC 3 to 26.4 VDC DC: 10 to 2.0 A 20 A (10 ms) 24 VDC 19.2 to 28.8 VDC 4 k 20% 19.2 VDC max. * The applicable output load current varies depending on the ambient temperature. Refer to reference data theLoad Current vs. Ambient Temperatur rating characteristic for details. Without Input Resistance Item Symbol G3DZ-1R5PLG G3DZ-DZ02PG Max. input current 50 mA max. IIN Rated current 6.25 mA (recommendation value) Must operate IOP 4 mA max. current Input Must release IRE 0.6 mA max. current Input release VR 3 V voltage G 3 Foward voltage VF 1.4 V (TYP) D 3 to 125 VAC Z Load voltage range 3 to 26.4 VDC 3 to 125 VDC Output Load current 100 to 0.5 A 100 to 2.0 A Inrush current 5 A (10 ms) 20 A (10 ms) Characteristics (at 25C) Item Model G3DZ-2R6PL G3DZ-1R5PL G3DZ-1R5PLG G3DZ-DZ02P G3DZ-DZ02PG Operate time * 6 ms max. Release time * 10 ms max. Output ON-resistance * 2.4 max. 3.0 max. 0.15 max. 10 A max. (at 125 VDC) 10 A max. (at 125 VDC) Leakage current at OFF state 10 A max. (at 26.4 VDC) 100 A max. (at 200 VAC) 50 A max. (at 100 VAC) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between input and output Vibration resistance 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 2 Shock resistance 1,000 m/s Storage temperature 30C to 100C (with no icing or condensation) Ambient operating temperature 30C to 85C (with no icing or condensation) Ambient operating humidity 45% to 85%RH Weight Approx. 3.1 g Approx. 2.8 g Approx. 2.4 g Approx. 2.6 g Approx. 2.4 g * Measurement conditions:For G3DZ-2R6PL/-1R5PL/-DZ02P, the values are under the measurement conditions whereby rated voltages are applied to the input For G3DZ-1R5PLG/-DZ02PG, the values are measured with 6.25 mA current applied to the input. 2