G2RG-X PCB Power Relay Power Relay with 500 VDC 10 A Switching Capacity (2 poles series wiring with 3.0 mm contact gap) Achieves 500 VDC 10 A switching capacity used with 2 pole series wiring 3.0 mm contact gap (2 poles series wiring) Offers high insulation with insulation distance above 8 mm and impulse withstand voltage of 10 kV between coil and contacts. UL and TV certified RoHS Compliant Model Number Legend Application Example Energy storage system G2RG-2A -X 12 3 1. Number of Poles 2. Contact Form 3. Enclosure rating G 2: 2-pole A: N.O. contact Blank: Flux protection 2 DPST-NO (2a) R G Ordering Information Characteristics I X Contact Enclosure Terminal Rated coil Minimun Contact resistance *1 100 m max. Model form rating type voltage packing unit Operate time 15 ms max. DPST-NO Flux PCB 12 VDC Release time 5 ms max. G2RG-2A-X 60 pcs/tray (2a)* protection terminals 24 VDC Max. Mechanical 18,000 operations/hr Note. When ordering, add the rated coil voltage (V) to the model number. switching Example: G2RG-2A-X DC12 frequency Electrical 1,800 operations/hr Rated coil voltage Insulation resistance *2 1,000 M min. However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Between coil 5,000 VAC, 50/60 Hz for 1 min * This product is designed and manufactured under the assumption that it will and contacts be used with 2 poles series wiring. Between Dielectric contacts of 3,000 VAC, 50/60 Hz for 1 min Ratings strength different polarity Between Coil contacts of the 1,000 VAC, 50/60 Hz for 1 min same polarity Item Must-operate Must-release Maximum Rated Coil Power Impulse withstand voltage 10 kV (1.2 x 50 s) voltage voltage voltage current resistance consumption (V) (V) (V) Insulation Between coil and (mA) () (mW) Clearance: 8 mm, Creepage: 8 mm distance contacts Rated voltage % of rated voltage 10 to 55 to 10 Hz, 0.75 mm single amplitude 12 VDC 66.6 180 110% Approx. Destruction 80% max. 10% min. (1.5 mm double amplitude) Vibration (at 23C) 800 24 VDC 33.3 720 resistance 10 to 55 to 10 Hz, 0.75 mm single amplitude Note 1. The rated current and coil resistance are for a coil temperature of 23C Malfunction (1.5 mm double amplitude) and have a tolerance of 10%. 2 Destruction 1,000 m/s Note 2. The operating characteristics given in the above table are for a coil Shock temperature of 23C. 2 resistance Malfunction 200 m/s when energized Note 3. The maximum allowable voltage is the maximum possible value of the 1,000,000 operations min. voltage that can be applied to the relay coil. Mechanical (at 18,000 operations/hr) Contacts (2-pole Series Wiring) Electrical *3 Durability 10,000 operations at 500 VDC 10 A (When resistive Item Load Resistive load 30,000 operations at 500 VDC 1 A load and 2 poles Contact type Single (switching frequency of 1,800 operations/hr) series wiring) Contact material Ag-alloy (Cd free) Ambient operating -40 to 85 C (with no icing or condensation) Rated load 10 A at 500 VDC temperature Rated carry current 8 A Ambient operating humidity 5% to 85% Maximum switching voltage 500 VDC Weight Approx. 22 g Maximum switching current 10 A Note. The above values are initial values (at an ambient temperature of 23C.) *1. Measurement conditions: 5 VDC, 1 A, voltage-drop method. It is a value between each contact terminal. *2. Measurement conditions: Measured with a 500 VDC megohmmeter at the same places as the dielectric strength. *3. A diode and zener diode are connected to the relay coil. 1G2RG-X PCB Power Relay Please visit our website, which is noted on the last page. CAD Data Dimensions (Unit: mm) G2RG-2A-X PCB Mounting Holes Terminal Arrangement/ (Bottom View) Internal Connections 23.5 max. 29 max. (22.8)* Tolerance: 0.1 mm (Bottom View) 5 (28.6)* 13.5 max. 8.6 (12.8)* (+) Six, 1.3-dia. holes 1 34 7.5 29.5 max. (-) (28.5)* 8 6 5 17.2 (2.1) 20 The contacts have polarity. Exercise caution. 0.5 3.5 0.3 0.2 1 1 Use this product with 2 poles wiring series. * Average value (No coil porality) CAD Data Approved Standards The approved rated values for international standards are different to the individually specified characteristic values. Be sure to confirm that required standards are satisfied before actual use. UL Recognized: (File No. E41643) Number of test G Model Contact form Coil ratings Contact ratings operations 2 R 10 A, 500 VDC (Resistive) 85C 10,000 G2RG-2A-X DPST-NO (2a) 12, 24 VDC G 1 A, 500 VDC (Resistive) 85C 30,000 I X EN/IEC, TV Certified Model (Approval/No. R50468711) Number of test Model Contact form Coil ratings Contact ratings operations 10 A, 500 VDC (Resistive) 85C 10,000 G2RG-2A-X DPST-NO (2a) 12, 24 VDC 1 A, 500 VDC (Resistive) 85C 30,000 Circuit Diagrams Load (+) 13 4 (-) 86 5 Note. The contacts have polarity. Exercise caution. The diode and zener diode are for coil surge absorption. (The coil has no polarity.) 2