Floatless Level Switch (Compact Type)
61F-G@N
CSM_61F-G_N_DS_E_3_5
Improved Design for a More Lightweight
Construction and Reduced Standby Power
Consumption.
Standby power reduced to 85% or less of previous models.
(Applicable to 61F-GN.)
Weighs only 85% or less of previous models. (Applicable to
61F-G3N/-G4N.)
Easy identification of operating status with LED operation
indicator.
Increased reliability of internal relay (micro load: 5 VDC, 1 mA)
to enable PLC input.
Electrode terminals and other wiring terminals are separated for
61F-G@N (120/240 VAC) in this catalog have been discontinued
easy wiring.
at the end of March 2018.
Select from three mounting methods: JEM, DIN rail mounting,
or screw mounting.
Note: LED operation indicator is provided on Controllers manufactured in
August 1999 or later.
Refer to Safety Precautions for Floatless Level
Controllers.
Model Number Structure
Model Number Legend
61F-@N@
1 2
1. Controller Application 2. Type
Position of
G: Automatic water supply and Blank: General-purpose
LED Indicator
drainage
L 2KM: Long-distance (for 2 km)
G1: Automatic water supply with idling
L 4KM: Long-distance (for 4 km)
prevention or water shortage alarm
H: High-sensitivity
G2: Automatic water supply and
D: Low-sensitivity
drainage with abnormal water
R: Two-wire
increase alarm
Note: LED indicator is provided on
G3: Automatic water supply and
Controllers manufactured in
drainage with full tank and water
August 1999 or later.
shortage alarm
It is not mounted on the case
surface. It can be seen
G4: Automatic water supply with water
through the case.
level indicator for water supply tank
and water receiving tank and
prevention of idling due to water
shortage
I: Liquid level indication and alarm (no
two-wire models)
161F-G@N
Ordering Information
Classification by Set contents General- Long-distance High- Low- Two wire
application purpose (between sensitivity (for sensitivity (for
Controller and high specific low specific
Classification by Electrodes) resistance) resistance)
control purpose (See note 2.)
Controller GN 61F-GN Base x 1 61F-GN * 61F-GNL * 61F-GNH * 61F-GND * 61F-GNR *
Models 61F-11@ Units x 1
G1N w/pump idling 61F-G1N Base x 1 61F-G1N * 61F-G1NL * 61F-G1NH * 61F-G1ND * 61F-G1NR *
Models prevention 61F-11@ Units x 2
w/alarm for
abnormally low
level
G2N w/alarm for 61F-G2N Base x 1 61F-G2N * 61F-G2NL * 61F-G2NH * 61F-G2ND * 61F-G2NR *
Models abnormally high 61F-11@ Units x 2
level
G3N w/alarm for 61F-G3N Base x 1 61F-G3N * 61F-G3NL * 61F-G3NH * 61F-G3ND * 61F-G3NR *
Models abnormally high 61F-11@ Units x 3
and low levels
G4N w/level 61F-G4N Base x 1 61F-G4N * 61F-G4NL * 61F-G4NH * 61F-G4ND * 61F-G4NR *
Models display of water 61F-11@ Units x 5
source and tank MY3 Relay x 1
IN Level indication 61F-IN Base x 1 61F-IN * 61F-INL * 61F-INH * 61F-IND * 61F-INR
Models with alarm 61F-11@ Units x 2
Relay unit 61F-11@ Units x 1 61F-11N 61F-11NL 61F-11NH 61F-11ND 61F-11NR
Note: 1. : Automatic water supply and drainage control, : Automatic water supply control
2. Subclassified into 2 km and 4 km models according to the model of relay unit used. Specify 2 km or 4 km when ordering.
3. When ordering, specify the desired operating voltage at the end of the model number.
Example: 61F-GN[110/220 VAC]
Desired supply voltage
4. Contact your OMRON representative for products with voltages other than those listed above.
5. If you order with a standard model number, the corresponding Relay Units are also delivered as part of a set.
If you order the 61F-GN, one 61F-11 Relay Unit is included in the set.
* 61F-G@N (120/240 VAC) in this catalog have been discontinued at the end of March 2018.