2JCIE-BU
Environment Sensor (USB Type)
Sense a variety of environmental
information
Connects to a network via USB or Bluetooth to enable the
sending of measurement data
Using OMRONs unique and innovative algorithm, enables
highly accurate determination of earthquakes based on vibra-
tional acceleration
Enables continuous monitoring of room air quality using a VOC
sensor
RoHS compliant
Refer to Safety Precautions on page 3.
Ordering Information
Minimum packing unit
Model Communication Interface Output data
(Unit: pcs)
Temperature, Humidity, Light, Barometric pressure, Sound noise,
Bluetooth low energy
2JCIE-BU01 3-axis acceleration *1, eTVOC *2, Discomfort index *3, Heat stroke warning level *3, 1
USB communication
Vibration information *1 (No. of earthquakes, No. of vibrations, SI value *4)
Specifications
Ratings
Item Specification
Power Supply 5 V (USB power supply)
Sensors Temperature, Humidity, Light, Barometric pressure, Sound noise, 3-axis acceleration *1, eTVOC *2
Interface Bluetooth low energy (Bluetooth v5.0)*5, USB communication (USB2.0)
Communication range Approx. 10 m *6
Operating Temperature 10 to 60C
Operating Humidity 30 to 85%RH
Dimensions Approx. 29.1 14.9 7.0 mm
Weight Approx. 2.9 g
Absolute maximum ratings Power supply 0.3 to 5.5 V
Absolute maximum ratings Output current Max. 100 mA
Absolute maximum ratings Temperature 20 to 70C
Recommended operating condition Power supply 4.75 to 5.25 V
Characteristics
Item Measurable range Accuracy (Vcc = 5.0 V, Ta = 15 to 35C if not specified) *7
Temperature 10 to 60C 2C
Humidity 0 to 100%RH 5%RH
Light 10 to 2000 lx 100 lx
Barometric pressure 700 to 1100 hPa 4 hPa
Sound noise 40 to 94 dB For reference *8
3-axis acceleration 2000 to 2000 mg For reference *1, *8
eTVOC 0 to 32768 ppb For reference *2, *8
*1. 3-axis acceleration values can only be obtained in the specified operation mode. For details, refer to the Communication Interface Manual.
*2. eTVOC (equivalent Total Volatile Organic Compounds) refers to the total concentration of volatile organic compounds in a room environment. Output TVOC values
will be higher or lower depending on the type of volatile organic compound. Also, if continuously operated in high-temperature and high-humidity environments,
sensitivity for eTVOC values may decrease.
*3. Information for heat stroke and discomfort index are only guidelines to be used for air conditioning and physical condition management. An individual difference
and physical condition will greatly affect an individual feeling. Sensor output is not to be used for determining the presence of symptoms. Use only as a guideline.
Warning levels for heat stroke may not be the same as those issued by public institutions.
*4. SI (Spectral Intensity) values corresponds to the destructive energy seismic motions exert on a structure.
*5. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by OMRON Corporation is under license.
*6. Communication distance may vary according to obstacles between the communication equipment, radio wave conditions.
*7. Performance values are obtained based on the various conditions of individual tests, and do not guarantee the values obtained under combined conditions for rated
values and performance values.
*8. Reference output values are provided for reference only, and do not guarantee that operation will always take place normally within that range.
12JCIE-BU Environment Sensor (USB Type)
Dimensions (Unit: mm)
Vent hole
12
12
14.9
29.1
LED indicator
Window
7
4.5
Vent hole
CAD Data
2