Product Information

R65-11AD10

R65-11AD10 electronic component of NTE

Datasheet
DIGITAL TIME DELAY RELAY/COUNTER

Manufacturer: NTE
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 407.2791 ea
Line Total: USD 407.28

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1
1 : USD 407.2791
3 : USD 370.682
5 : USD 365.924

0 - WHS 2


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1
1 : USD 497.7336
100 : USD 496.1424
500 : USD 494.5512
1000 : USD 474.4974

     
Manufacturer
Product Category
No Of Digits / Alpha
Digit Height
Supply Voltage Min
Supply Voltage Max
Panel Cutout Height
Panel Cutout Width
Carry Current
Coil Voltage Ac Max
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
R66-11CA10-120 electronic component of NTE R66-11CA10-120

R6611CA10120 nte
Stock : 2

R66-11CA10-240 electronic component of NTE R66-11CA10-240

R6611CA10240 nte
Stock : 0

R66-5A10-120 electronic component of NTE R66-5A10-120

R665A10120 nte
Stock : 0

R66-5A10-240 electronic component of NTE R66-5A10-240

R665A10240 nte
Stock : 0

R67-11A10-120 electronic component of NTE R67-11A10-120

Electromechanical Relay 120VAC 10A DPDT (60.96x44.95x73)mm THT Voltage Relay
Stock : 0

R67-11A10-24 electronic component of NTE R67-11A10-24

RELAY VOLTAGE MONITORING DPD
Stock : 0

R67-11D10-24 electronic component of NTE R67-11D10-24

RELAY VOLTAGE MONITORING DPD
Stock : 0

R68-5A10-480 electronic component of NTE R68-5A10-480

Electromechanical Relay 208/480VAC 10A SPDT(60.96x44.95x74)mm Plug-In Phase Monitoring Relay
Stock : 0

R70-5D1-12 electronic component of NTE R70-5D1-12

Electromechanical Relay 12VDC 960Ohm 1/0.5A SPDT (12.5x7.5x10)mm THT Telecom Relay
Stock : 0

R70-5D1-24 electronic component of NTE R70-5D1-24

Signal Relay 24VDC 1A SPDT (( 12.5mm 7.5mm 10mm)) Through Hole
Stock : 0

Image Description
R6513-00 electronic component of Harwin R6513-00

Standoffs & Spacers 12.7 LG THREADED SELF/LOCK SPACER
Stock : 1150

CRCW060315K0FKEC electronic component of Vishay CRCW060315K0FKEC

CRCW Series 0603 15 k 1% 0.1 W 100 ppm/K SMT Thick Film Chip Resistor
Stock : 0

R6607 electronic component of Brady R6607

6600 Series 4.330 x 984 Thermal Printer Ribbon with Black Resistant Ink
Stock : 0

JANTXV1N5526CUR-1 electronic component of Microchip JANTXV1N5526CUR-1

n/a
Stock : 0

KUSB1052 electronic component of Kaga Electronics KUSB1052

AC/DC WALL MOUNT ADAPTER 5V 10W
Stock : 0

02201007 electronic component of Hubbell 02201007

DBL EYE, SUP GRIP, 1.5 1.7inch, BRZ, CLS
Stock : 0

02203038 electronic component of Hubbell 02203038

OFF EYE, SUP GRIP, .63 .74inch, BRZ, ROD
Stock : 0

02204005 electronic component of Hubbell 02204005

MED SUPPORT GRIP, 2.00 2.49inch, BRZ
Stock : 0

JANTXV1N4625UR-1 electronic component of Aeroflex JANTXV1N4625UR-1

Diode Zener Single 5.1V 5% 500mW 2-Pin DO-213AA
Stock : 0

JANTXV1N4621UR-1 electronic component of Aeroflex JANTXV1N4621UR-1

Diode Zener Single 3.6V 5% 500mW 2-Pin DO-213AA
Stock : 0

Features R65 Series 10 Programmable Timing Modes + 2 Counting Modes 0.1 sec to 9,990 hr. Programmable Timing Range 1 to 99,900 Counting Range LCD Digital Display Programmable, DPDT, 10 Amp, AC or Thumbwheel Switches for Programming DC, Multifunctional, Digital Time Delay Relay/Counter. D46 ON NC NO A 2 1 4 S .320 (8.1) 2.830 (71.9) 3.150 (80.0) .640 (16.3) 1.760 (44.7) DPDT, 2 Form C DPDT, 2 Form C Sq. RESET External Control Switches** CONTROL CONTROL (COUNT) 1.880 (47.8) Sq. RETURN Electrical Specifications RETURN RESET Use Same For RESET 6 6 Contact 5 7 5 7 Rating: 10 Amps 30VDC or 277VAC, resistive 4 4 8 8 1/2 HP 250VAC 1/3 HP 120VAC Life: 100,000 operations at minimum rated load 3 3 9 9 Mechanical Life: 10,000,000 operations 2 2 10 10 1 11 1 11 Input Nominal Input voltage: 24 240V 15%, 50/60Hz AC or DC + + INPUT* INPUT* Nominal Power: See Chart Timing * Note input polarity for DC operation. For most reliable operation on AC, connect high side to + and low side to . Timing Ranges: 0.1 to 99.9 / 1 to 999 sec 0.1 to 99.9 / 1 to 999 min 0.1 to 99.9 / 1 to 999 / 10 to 9,990 hr. ** IMPORTANT: A dry circuit switch is recommended. A dry circuit switch Timing Adjustments: Digital adjustment via thumbwheel switches is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay Tolerance: 0.1% 0.05 sec to function properly. Delta Time (for AC units add 1 cycle 60Hz): 0.1% 0.05 sec Repeatability: 0.1% 0.05 sec including first cycle of operation Reset Time (power interruption): 45mS, typ 60 mS, max Minimum Pulse Width, Control: 50mS Recycle Time: 45mS, typ 60mS, max AC or DC OPERATED Counting Max. Contact Maximum Count: 1 to 999 10 to 9,990 ( 10) 100 to 99,900 ( 100) Timing Nom Cur. Maximum Count Rate: 100 counts per second NTE Adj Count Contact Vltg Nom 28VDC Diag Type No. Minimum Pulse Width: Range Range Arr. AC/DC Power 120VAC No. Count (Control): 3mS R6511AD10 0.1 Sec 1 DPDT 24 1W 24V 10A D46 Reset: 3mS to to to 5W 120V 9,990 Hr. 99,900 240 10W 240V Available Counting Functions: Operate at preset count and release at preset count Protection Transient: yes ACCESSORIES Dielectric Strength Between Open Contacts: 1000V , 60Hz rms MOUNTING NTE Between All Other Conductors: 1500V , 60Hz STYLES DESCRIPTION TYPE NO. rms Environmental Characteristics SURFACE MOUNT 11PIN OCTAL R95104 Operating: 10C to +55C PANEL MOUNT 11PIN OCTAL R95119 Storage: 20C to +70C DIN RAIL MOUNT 11PIN OCTAL R95114 Weight DIN RAIL MOUNT 11PIN OCTAL R95182 Std: 4.3 oz (122 grams) approx. 70 NTE Electronics, Inc. Voice (973) 7485089 FAX (973) 7486224 R65 Series (Continued) Programming Switch Diagram A 2 1 4 S Function Select Timer/Counter Select Time Base Select Timer Mode: 001 to 999 Timer Base: A Delay On Operate .1S 0.1 to 99.9 Sec B Delay On Release S 1 to 999 Sec C Interval On D ControlOff Interval On .1M 0.1 to 99.9 Min E Recycle M 1 to 999 Min F Single Cycle G Control OnOff Interval On .1H 0.1 to 99.9 Hrs H Control OnOff Delay H 1 to 999 Hrs I Pulse 10H 10 to 9990 Hrs J Cumulative Delay On Operate Counter Select Counter Mode Select Counter Mode: CO Operate at Preset Count A, DJ Normal Count CR Release at Preset Count B Divide by 10 C Divide by 100 NOTE: With this setting, the relay would operate after a delay period of 214 seconds. Timer Function Descriptions started by momentary CONTROL input or poweron with CONTROL A. Delay On Operate on. Relay stays on for equal time interval, then turns off. RESET Output relay turned on at end of programmed time interval which is terminates timing and turns relay off. Turning RESET off does not started by CONTROL input or poweron with CONTROL on. Relay restart timing. turned off by RESET input until next cycle is started. With CONTROL on, turning RESET off restarts timing. G. Control OnOff Interval On (Watch Dog Timer) B. Delay On Release Output relay turned on and programmed time interval started of Output relay turned on with CONTROL input and remains on for restarted by chang of CONTROL input. RESET turns relay off and programmed time interval following removal of CONTROL. During time stops timing. Turning RESET off does not restart timing. interval after release of CONTROL, RESET turns relay off until cycle restarted with reapplication of CONTROL With CONTROL on, relay is H. Control OnOff Delay held off while RESET is activated. Output relay turned on at end of programmed timing interval which is started or restarted by charge of CONTROL input. If relay is on, trunoff C. Interval On of relay occurs at end of programmed time interval which is started or Output relay turned on for programmed time interval by CONTROL or restarted by charge of CONTROL input. RESET turns relay off and poweron with CONTROL on. RESET turns relay off until next cycle stops timing. Turning RESET off does not restart timing. is started, and does not restart timing when RESET is removed. I. Pulse D. ControlOff Interval On Output relay turned on at end of programmed time interval, which is Output relay turned on for programmed time interval by turnoff of started by CONTROL input, for 0.5 second duration, and continues in CONTROL. RESET truns relay off until next cycle is started, and does pulsed mode at programmed time interval with fixed 0.5 second not restart timing when RESET is removed. ontime. Turning CONTROL off turns relay off and stops timing. RESET turns relay off and inhibits operation. With CONTROL on, E. Recycle removal of RESET restarts timing. Output relay turned on at end of programmed time interval which is J. Cumulative Delay On Operate started by momentary CONTROL input or poweron with CONTROL Output relay turned on at completion of total accumulate CONTROL on. Relay stays on for equal time interval, then turns off and cycle is input duration equal to programmed time. Turning CONTROL off repeated on a freerunning basis until terminated by momentary before accumulation of programmed time results in measured time total RESET, turning relay off. With CONTROL on, turning RESET off being held until CONTROL is again turned on and total programmed restarts cycle. time value is reached. RESET input resets time value to zero and turns F. Single Cycle relay off if energized. Turning RESET off restarts timing if CONTROL Output relay turned on at end of programmed time interval which is is on. Counter Function Descriptions Operation is similar to CO (Operate at Preset Count) except relay turns CO. Operate at Preset Count Normal Mode off at preset count. After initializing by momentary activation of RESET input, each on/off signal at COUNT (CONTROL) input increments displayed count in upcounting manner from initial 000 value until preset count, set by CO or CR. Divideby10 Mode thumbwheel switches, is reached and output relay turns on. Additional Operation is as described previously, except count is incremented for inputs continue to increment displayed count. Continued counting past every 10 on/off input signals for a maximum presettable count of 9,990. maximum count (999) results in a wraparound effect to 000, followed by continued upcounting. Activation of RESET input turns relay off CO or CR. Divideby100 Mode and resets count to zero. Operation is as described previously, except count is incremented for CR. Release at Preset Count Normal Mode every 100 on/off input signals for a maximum presettable count of Initializing by momentary activation of RESET input turns relay on. 99,900. 71 NTE Electronics, Inc. Voice (973) 7485089 FAX (973) 7486224

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted