D1U4-W-1600-54-HBxC www.murata-ps.com AC-DC Power Supply PRODUCT OVERVIEW The D1U4-W-1600-54-HBxC is a 1600W power factor corrected (PFC) front end power module intended for hot swap redundant systems. There is a main output of 54VDC ( oating with respect to chassis ground) and a 12VDC Standby/ bias output (that is present whenever the incoming AC source is applied. The form factor is suitable for 1RU chassis enclosures and is designed to deliver reliable bulk DC power to servers, workstations, storage systems, PoE switches or any 54VDC distributed power architecture requiring high power density. The high effi ciency design supports speed controlled dual DC fans in a thermally optimized package that is self-pro- tecting and able to auto recover from over-current and over-temperature events. Visual status information is provided via front panel mounted LED indicators in addition to hardware logic signals and a PMBus management interface. ORDERING GUIDE Power Output High Power Output Low Standby Model Number Main Output Air ow Line AC Line AC Output D1U4-W-1600-54-HB4C Back to front 1600W 1200W 54V 12V D1U4-W-1600-54-HB3C Front to back FEATURES 1600W Output Power INPUT CHARACTERISTICS 1.6 (1U) x 14.0 x 4.0 Parameter Conditions Min. Typ. Max. Units (41.0mm x 355.6mm x 101.6mm) Input Voltage Operating Range 90 115/230 264 Vac Input Frequency 47 50/60 63 Hz 54VDC Main PoE compatible Turn-on Input Voltage Ramp Up 81 89 12V SB Output Vac Turn-off Input Voltage Ramp Down 70.5 78.0 PMBus Power Management Bus supported by Maximum Current VIN = 200Vac 1600W 10 Arms dual redundant I2C interfaces. Maximum Current VIN = 90Vac 1200W 15 N+1 Redundancy Capable hot swap (up to 8 Inrush Current Cold start between 0 to 1ms 100 Apk modules in parallel) Power Factor At 230Vac FL 0.95 Active current sharing on 54VDC Main output OUTPUT VOLTAGE CHARACTERISTICS integral bidirectional MOSFET output isolation Output device Parameter Conditions Min. Typ. Max. Units Voltage Over-Voltage, Over-Current Over-Temperature Voltage Set Point 54V Vdc Protection Line & Load Regulation 52.38 55.62 Internal variable speed cooling fans 54V Output Current 0 30 A 1 Ripple Voltage & Noise 20MHz Bandwidth 540 mVp-p 20ms full cycle hold up Load Capacitance 3800 24,000 F RoHS Compliant Voltage Set Point 12 Vdc Two-year warranty Line & Load Regulation 11.64 12.36 12V Output Current 0 2 A 1 Ripple Voltage & Noise 20MHz Bandwidth 33 mVp-p Load Capacitance 1530 F 1 Ripple and noise are measured with a parallel combination of a 0.1F ceramic capacitor and 2 x 270F OSCON capacitors on each of the power module outputs measurement nodes. See test set up diagram below. www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html Available now at www.murata-ps.com/en/3d/acdc.html CB For full details go to Test Certi cate PM www.murata-ps.com/rohs and Test Report www.murata-ps.com/support CPS D1U4-W-1600-54-HBxC.B04 Page 1 of 6D1U4-W-1600-54-HBxC AC-DC Power Supply RIPPLE MEASUREMENT 0.1uF Ceramic 2x270uF OSCON Power Supply Load Box AC Phase AC Ground BNC to BNC Shielded Cable General Notes: 1. Load the outputs at specified minimum output current. Oscilloscope 2. Connect the probe as shown with the 20MHz BW input tip and ground as short as possible. 3. Take all measurements 4. Repeat the measurements with the outputs at specified maximum output current. OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Remote sense is not enabled on these variants due to the System Control feature and the relatively wide line & Remote Sense load regulation window. Efficiency 230Vac (excluding fan) 90 % Overshoot less than 10% for all outputs no negative transition at Output Rise (Monotonic) 10% to 95% rise time turn off. AC Ramp Up 3 s Startup Time PS ON activation 250 ms 54VDC 50% step (50-100% 100%-50%) 2700 load 1A/s Transient Response mV 12VSB 1A/s 250 Current Sharing Accuracy (up to 8 in parallel) At 100% load 10 % Hot Swap Transients 5 % Hold Up Time 100% load 230Vac nominal 20 ms ENVIRONMENTAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Storage Temperature Range Non-Condensing -40 70 C Operating Temperature Range 0 50 Operating Humidity Non-Condensing 10 90 % Storage Humidity 5 90 Altitude 3000 M Shock Non-Operating 30 G Operational Vibration Operational, 0.5G 5-500Hz MTBF Telcordia SR-332 40C 630 K Hours CAN/CSA-C22.2 No.60950-1-07 Am 1:2011 ANSI/UL 60950-1-2011 Safety Approvals IEC60950-1:2005 (2nd Ed)+A1:2009 and EN60950-1:2006/A11:2009/A1:2010/A12:2011 CQC GB4943,1-2011 Input Fusing Internal 20A/250V rated fast blow in AC line Weight 4.63/2.1 lbs/kg www.murata-ps.com/support CPS D1U4-W-1600-54-HBxC.B04 Page 2 of 6