200W Slim Type with PFC Switching Power Supply UHP-200 series Bauar t gep r u f t S i c h e r h e i t e g e l m a ge o d o s b e w a c g w w w . t u v . c o m ID 2000000000 GB4943 UL60950 -1 EN60950-1 IEC60950-1 EN60335-1 % -~+ R File Name:UHP-200-SPEC 2019-05-15200W Slim Type with PFC Switching Power Supply UHP-200 series SPECIFICATION MODEL UHP-200 -3.3 UHP-200 -4.2 UHP-200 -5 UHP-200 -12 UHP-200 -24 UHP-200 -36 UHP-200 -48 UHP-200 -15 DC VOLTAGE 3.3V 4.2V 5V 12V 15V 24V 36V 48V RATED CURRENT 40A 40A 40A 16.7A 13.4A 8.4A 5.6A 4.2A RATED POWER(convection) 132W 168W 200W 200.4W 201W 201.6W 201.6W 201.6W RIPPLE & NOISE (max.) Note.2 150mVp-p 150mVp-p 200mVp-p 240mVp-p 240mVp-p 240mVp-p 240mVp-p 300mVp-p VOLTAGE ADJ. RANGE 3.6~4.4V 3.2~3.5V 4.5~5.5V 11.4~12.6V 14.3~15.8V 22.8~25.2V 34.2~37.8V 45.6~50.4V OUTPUT VOLTAGE TOLERANCE Note.3 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.3% 0.3% 0.3% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 2000ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load HOLD UP TIME (Typ.) 10ms/230VAC 10ms/115VAC VOLTAGE RANGE Note.4 90 ~ 264VAC 127 ~ 370VDC FREQUENCY RANGE 47 ~ 63Hz PF0.94/230VAC PF0.98/115VAC at full load POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) 89% 90% 91% 93% 94% 94% 94% 94% AC CURRENT (Typ.) 2.2A/115VAC 1.1A/230VAC INRUSH CURRENT (Typ.) Cold start 40A/115VAC 80A/230VAC LEAKAGE CURRENT <0.75mA / 240VAC 110~140% rated output power OVERLOAD Protection type : Hiccup mode, recovers automatically after fault condition is removed PROTECTION 3.8~ 4.6V 4.62 ~ 5.46V 5.75 ~ 6.75V 13.2 ~ 15.6V 16.5 ~ 19.5V 26.4 ~ 31.2V 39.6 ~46.8V 52.8 ~ 62.4V OVER VOLTAGE Protection type :Shut down O/P voltage,re-power on to recover OVER TEMPERATURE Protection type :Shut down O/P voltage, recovers automatically after temperature goes down DC OK SIGNAL(Optional) Contact rating(max.):15Vdc/10mA resistive load FUNCTION For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically REDUNDANT(Optional) enabled. This can prevent the system crash, and provide the reliability of system WORKING TEMP. -30 ~ +70(Refer to Derating Curv) 20 ~ 95% RH non-condensing WORKING HUMIDITY -40 ~ +85, 10 ~ 95% RH non-condensing ENVIRONMENT STORAGE TEMP., HUMIDITY 0.03%/ (0 ~ 50) TEMP. COEFFICIENT 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes VIBRATION SAFETY STANDARDS UL60950-1,TUV EN60950-1,EN60335-1, CCC GB4943, EAC TP TC 004, BSMI CNS14336-1 approved, Design refer to EN61558-1,-2-16 WITHSTAND VOLTAGE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25/ 70%RH EMC EMC EMISSION Compliance to EN55032,GB9254,Class B, EN55014,EN61000-3-2,-3,EAC TP TC 020,BSMI CNS13438 (Note.6) EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11 EN61000-6-2 (EN50082-2), heavy industry level ,criterial A,EAC TP TC 020 MTBF 257K hrs min. MIL-HDBK-217F (25) OTHERS 194*55*26mm (L*W*H) DIMENSION 0.468kg 24pcs/12.2kg/0.49CUFT PACKING NOTE The The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name:UHP-200-SPEC 2019-05-15