Product Information

SE-330-SMA

SE-330-SMA electronic component of Littelfuse

Datasheet
Relay Sockets & Fixings SURFACE MT ADAPTOR

Manufacturer: Littelfuse
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 381.3944 ea
Line Total: USD 381.39

1 - Global Stock
Ships to you between
Thu. 23 May to Mon. 27 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
1 - WHS 1


Ships to you between Thu. 23 May to Mon. 27 May

MOQ : 1
Multiples : 1

Stock Image

SE-330-SMA
Littelfuse

1 : USD 355.5967
10 : USD 332.0746

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Series
Brand
Product Type
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
Mxhts
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
0216.500MXEP electronic component of Littelfuse 0216.500MXEP

Littelfuse Cartridge Fuses 250V .5A Fast Acting
Stock : 1

Hot 0235.500MXP electronic component of Littelfuse 0235.500MXP

500 mA 250 V AC DC Fuse Cartridge, Glass Holder 5mm x 20mm
Stock : 1

0218.032HXP electronic component of Littelfuse 0218.032HXP

Cartridge Fuses 250V .032A Time Lag (Slo-Blo)
Stock : 1

0229003.HXSP electronic component of Littelfuse 0229003.HXSP

3 A 250 V AC 125 V DC Fuse Cartridge, Glass Requires Holder 2AG, 5mm x 15mm
Stock : 130

01070002Z electronic component of Littelfuse 01070002Z

Littelfuse Fuse Clips Clip 916 Dia
Stock : 1

022903.5MXP electronic component of Littelfuse 022903.5MXP

Cartridge Fuses 3.5A 250V Tube,4.2x14.1mm RoHS
Stock : 1

02292.25HXP electronic component of Littelfuse 02292.25HXP

2.25 A 250 V AC 125 V DC Fuse Cartridge, Glass Holder 2AG, 5mm x 15mm
Stock : 0

0235.200MXP electronic component of Littelfuse 0235.200MXP

Cartridge Fuses 250V .2A Fast Acting
Stock : 1

0235002.VXP electronic component of Littelfuse 0235002.VXP

Cartridge Fuses 250V 5X20mm P 2AMP
Stock : 0

00713200 electronic component of Littelfuse 00713200

Pushbutton Switches Plunger Switch 2-Way N.C.
Stock : 0

Image Description
6-1393161-5 electronic component of TE Connectivity 6-1393161-5

TE Connectivity Schrack Relay Sockets & Hardware RY16037
Stock : 1

RY16037 electronic component of TE Connectivity RY16037

Relay Accessories Plastic Retaining Clip for Electromechanical Relay
Stock : 1

PYCM-08S electronic component of Omron PYCM-08S

Relay Sockets & Hardware CLIP AND RELEASE LEVER
Stock : 1

HC/HL-LEAF-SPRING-MK electronic component of Panasonic HC/HL-LEAF-SPRING-MK

Relay Sockets & Hardware Leaf Spring for HC/HL Relays
Stock : 1

3-1393161-4 electronic component of TE Connectivity 3-1393161-4

Relay Sockets & Hardware PLASTIC RETAINING CLIP
Stock : 1

RT78725 electronic component of TE Connectivity RT78725

TE Connectivity Schrack Relay Sockets & Hardware DIN SCRW TERM RT
Stock : 1440

RT16041 electronic component of TE Connectivity RT16041

TE Connectivity Schrack Relay Sockets & Hardware PLASTIC RETAINING CLIP
Stock : 1

Hot PFC-A1 electronic component of Omron PFC-A1

Relay Sockets & Hardware SOCKET CLIP 1pc equals 2 clips
Stock : 1

Hot PFP-M electronic component of Omron PFP-M

Relay Sockets & Hardware DIN RAIL STOP PLATE
Stock : 1

PYC-3 electronic component of Omron PYC-3

Relay Sockets & Hardware SOCKET CLIP
Stock : 0

Protection Relays Neutral-Grounding-Resistor Monitoring SE-330, SE-330HV SERIES Neutral-Grounding-Resistor Monitor Description The SE-330 is an advanced ground-fault and neutral-grounding- resistor monitoring relay that is compliant with Rule10-302 of the 2018 Canadian Electrical Code Part I (CE Code). It measures neutral current, neutral-to-ground voltage, and neutral-to-ground resistance. It provides continuous monitoring of the neutral-to-ground path to verify that the neutral-grounding resistor (NGR) is intact and that it has not been bypassed or shorted. An open NGR renders current- sensing ground-fault protection inoperative and could result in a false belief that the system is functioning properly. A shorted NGR results in higher-than-expected ground-fault current. The SE-330 can be used with low- and medium-voltage transformers and generators with low- or high-resistance grounding used in processing, manufacturing, chemical, pulp and paper, petroleum, and water-treatment facilities. For high-voltage applications, use the SE-330HV. For applications that require conformance to Australian standards, use the SE-330AU. Simplified Circuit Diagram Resistor Monitoring The SE-330 combines the measured values of resistance, current, and voltage to continuously determine that an NGR is intact. It is able to detect an open or shorted resistor with or without a ground fault present. Sensing resistors are matched to the system voltage CT B and are used to monitor NGRs on systems up to 72 kV. ER SERIES Ground-Fault Monitoring SE-330 SERIES (Sensing Resistor) The SE-330 uses an application-appropriate current transformer to (NGR Monitor) NGR A L1 reliably detect ground-fault currents as small as 100 mA. Discrete- L2 Fourier Transform (DFT) filtering ensures that false trips due to harmonic noise from adjustable-speed drives do not occur. Should For detailed wiring diagram, see adjacent page. the resistor open and a ground fault subsequently occur, the SE-330 will detect the fault through voltage measurement, while other Ordering Information current-only sensing relays would be ineffective. ORDERING POWER K4 UNIT HEALTHY COMM NUMBER SUPPLY CONTACT Pulsing Ground-Fault Location SE-330 - X X - 0 X The SE-330 is capable of controlling a pulsing contactor, which is used to switch the NGR resistance in a pulsing-compatible NGR 0=USB Only package. The resulting ground-fault current is distinguishable from 1=DeviceNet charging currents and noise and will only appear upstream of the 3=EtherNet ground fault, making fault location fast and easy, even without (Dual RJ45) SE-330 isolating feeders or interrupting loads. 4=EtherNet for applications (SC Fiber & RJ45) 0=120/240 0=Normally Open 35 kV or less Vac/Vdc 5=EtherNet Accessories (Dual SC Fiber) SE-330HV 1=Normally Closed 2=48 Vdc 6=IEC61850 for 72 kV ER Series Sensing Resistor A applications (Dual RJ45) Required interface between the power system and the 7=IEC61850 SE-330/SE-330HV. Eliminates hazardous voltage levels at (SC Fiber & RJ45) the relay. 8=IEC61850 (Dual SC Fiber) B ELCT5 Series Ground-Fault Current Transformer NOTE: For Australian applications, see the SE-330AU. Sensitive ground-fault current detection (5 A primary). ACCESSORIES REQUIREMENT ER Series Sensing Resistor Required ELCT30 Series Ground-Fault Current Transformer Sensitive ground-fault current detection (30 A primary). Current Transformer Required Other Current Transformer SE-IP65CVR-G Optional For low-resistance NGRs choose a CT primary SE-MRE-600 Optional approximately equal to the NGR rating. Inputs are provided for 1- and 5- A- secondary CTs. RK-332 Optional NGRM-ENC Optional SE-IP65CVR-G Hinged Transparent Cover PGA-0520 Optional Watertight cover, tamper resistant, IP65 protection. SE-330-SMA Optional Littelfuse reserves the right to make product changes, without notice. Material in this document is as accurate as known at the time of publication. Visit Littelfuse.com for the most up-to-date information. Rev: 4-D-042519 2019 Littelfuse Protection Relays & Controls 2018 Littelfuse Protection Relays & Controls Based on SE-330 Manual Rev: 11-A-063018 Littelfuse.com/se-330 Littelfuse.com/se-330hv Based on SE-330 HV Manual Rev: 5-M-101817Protection Relays Neutral-Grounding-Resistor Monitoring SE-330, SE-330HV SERIES Neutral-Grounding-Resistor Monitor Features & Benefits FEATURES IEEE BENEFITS Continuous NGR monitoring 3 Detects resistor failure within seconds, reduces transient-overvoltage risk, removes risk of ground-fault-detection failure Shorted NGR detection 3 Detects a ground fault on the neutral that could bypass the resistor, ensures fault current is not higher than expected Ground-fault detection 50G/N, 51G/N, 59N Main or backup protection to detect a ground fault anywhere on the monitored system Adjustable pickup (2-100%) Select greatest sensitivity without false operation, adjustable in 1% increments (MEM setting) Adjustable time delay (0.1 - 10 s) Adjustable trip delay allows quick protection and system coordination Universal CT compatibility Allows the use of a CT that gives required ground-fault settings Programmable output contacts Two programmable Form C and One programmable Form A (Ground Fault, Resistor Fault, Unit Health) Selectable contact Selectable fail-safe or non-fail-safe operating modes allows connection to shunt or undervoltage breaker operating mode coil or alarm circuit (K1, K2, and K3 output contacts) Analog output (4 - 20 mA) Connect an optional PGA-0520 meter or control system Pulsing output (SE-330 only) Control the operation of a pulsing ground-fault-location circuit Trip records On-board 100-event (with date and time) recorder helps with system diagnostics Harmonic filtering (DFT) Eliminate false trips due to harmonic noise from ASDs Local communications Mini USB port to view measured values, configure settings, and check event records Data logging On-board microSD card (included) can be used for long-term data logging Remotely view measured values and event records, reset trips, and cause a remote trip Available Protocol Options: IEC 61850 - with dual RJ45, SC Fiber and RJ45, or Dual SC Fiber Interface Network communications Modbus TCP and Ethernet/IP - with dual RJ45, SC Fiber and RJ45, or Dual SC Fiber Interface DeviceNet - with CAN interface Software PC-interface software (SE-MON330) is available at Littelfuse.com/RelaySoftware Selectable reset mode Selectable latching or auto-reset operation Unit-healthy output Verifies SE-330 is operating correctly, available as Form A or Form B output contact Conformal coating Internal circuits are conformally coated to protect against corrosion and moisture Typical Values NEUTRAL-GROUNDING RESISTOR SENSING RESISTOR GROUND-FAULT SYSTEM VOLTAGE V PICKUP LEVEL N PICKUP LEVEL CURRENT RESISTANCE RESISTANCE (VOLTS) (VOLTS) MODEL (AMPERES) (AMPERES) (OHMS) (SWITCH S5 SETTING) 480 5 55 ER-600VC 20 k 2.5 170 600 5 69 ER-600VC 20 k 2.5 200 2,400 5 277 ER-5KV 20 k 2.5 800 4,160 5 480 ER-5KV 20 k 3 1,700 7,200 10 416 ER-15KV 100 k 2 170 x 5 = 850 14,400 15 554 ER-15KV 100 k 3 340 x 5 = 1,700 DISCLAIMER: The above table is for illustrative purposes only. Actual values may differ based on a variety of individual system considerations, such as capacitive charging current and coordination study results. Specifications Wiring Diagram IEEE Device Numbers Ground Fault (50G/N, 51G/N, 59N), Checking Relay (3), Lockout Relay (86) 12 1 UNIT Input Voltage See ordering information CONTROL HEALTHY 13 POWER 2 Dimensions H 213 mm (8.4 ) W 98 mm (3.9 ) D 132 mm (5.2 ) RESET 3 GF Trip-Level Settings 2-100% of CT-Primary Rating in 1% increments POWER SYSTEM 15 NEUTRAL (X0) GF Trip-Time Settings 0.1-10 s 16 NEUTRAL-GROUNDING- 17 Vn Trip-Level Settings 20-2,000 Vac (5 kV systems) 100-10,000 Vac (>5 kV systems) RESISTOR MONITOR SENSING RESISTOR PULSE SE-330 SERIES (SE-330 ONLY) ER SERIES ENABLE Contact Operating Mode Selectable fail-safe or non-fail-safe (K1, K2, K3) +24 Vdc 18 ANALOG + 19 Harmonic Filtering Standard feature (required) OUTPUT N R 6 R 20 4-20 mA Reset Button Standard feature 7 G 21 0 V A G Output Contacts Two Form A and two Form C 22 Pulsing Circuit 1.0-3.0 s in 0.2 s increments (SE-330 only) TRIP OR PULSING 23 Approvals CSA certiefi d, UL Listed (E340889), CE (European Union), RCM (Australian) (K1) CURRENT TRANSFORMER EFCT FAMILY Communications Mini USB (standard) DeviceNet (optional), IEC 61850 (optional), 24 8 EFCT GROUND Modbus TCP and EtherNet/IP (optional) 25 9 1 A FAULT (required) (K2) 26 10 5 A Analog Output 4-20 mA, self or loop powered B 11 COMMON 27 Conformally Coated Standard feature RESISTOR 28 FAULT Warranty 5 years (K3) 29 Mounting Panel and Surface (optional) Littelfuse reserves the right to make product changes, without notice. Material in this document is as accurate as known at the time of publication. Visit Littelfuse.com for the most up-to-date information. Rev: 4-D-042519 2018 Littelfuse Protection Relays & Controls 2018 Littelfuse Protection Relays & Controls Based on SE-330 Manual Rev: 11-A-063018 Littelfuse.com/se-330 Littelfuse.com/se-330hv Based on SE-330 HV Manual Rev: 5-M-101817

Tariff Desc

8536.69.10 62 Plugs and sockets for co-axial cables or printed circuits Free

8536.69.90 CONNECTORS, ELECTRICAL, being ANY of the following:
(a) plugs;
(b) sockets;
(c) adaptors
TC 1225594

8535.29.00 Other ELECTRICAL APPARATUS FOR SWITCHING OR PROTECTING ELECTRICAL CIRCUITS, OR FOR MAKING CONNECTIONS TO OR IN ELECTRICAL CIRCUITS (FOR EXAMPLE, SWITCHES, FUSES, LIGHTNING ARRESTERS, VOLTAGE LIMITERS, SURGE SUPPRESSORS, PLUGS AND OTHER CONNECTORS, JUNCTION BOXES), FOR A VOLTAGE EXCEEDING 1 000 VOLTS:

7415 Nails, tacks, drawing pins, staples (other than those of 8305) and similar articles, of copper or of iron or steel with heads of copper; screws, bolts, nuts, screw hooks, rivets, cotters, cotter-pins, washers (including spring washers) and similar articles, of copper:
7415.39.00 Other
C&K Aerospace
HAMLIN
Hamlin Littelfuse
Hamlin / Littelfuse
Hamlin Inc
Hartland Controls / Littelfuse
LF
LF7
Littelfuse Teccor Sidactor Product
Littelfuse Wickmann Brand
Littelfuse / US Sensor
Littelfuse Inc
Littelfuse Inc.
LITTELFUSE SEMITRON
LITTELFUSE WICKMANN
LITTELFUSE, INC.
Little Fuse / Wickmann
Littlefuse
SSAC
SSAC Relays
TE Connectivity / Circuit Protection
WICKMANN USA

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted