Product Information

231-INSIDER-P

231-INSIDER-P electronic component of Littelfuse

Datasheet
Industrial Relays 380-480VAC 50/60Hz 6W 1PH VMON RELAY

Manufacturer: Littelfuse
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 169.545 ea
Line Total: USD 169.54

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Fri. 03 May to Thu. 09 May

MOQ : 1
Multiples : 1

Stock Image

231-INSIDER-P
Littelfuse

1 : USD 239.295

0 - Global Stock


Ships to you between Thu. 09 May to Mon. 13 May

MOQ : 1
Multiples : 1

Stock Image

231-INSIDER-P
Littelfuse

1 : USD 220.8902
10 : USD 202.0771
25 : USD 188.5947
50 : USD 186.4697
100 : USD 186.4697
250 : USD 186.4697

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Type
Contact Termination
Contact Form
Switching Voltage
Mounting Style
Mounting Type
Packaging
Series
Relay Contact Form
Power Consumption
Brand
Product Type
Factory Pack Quantity :
Subcategory
Cnhts
Hts Code
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
0216.500MXEP electronic component of Littelfuse 0216.500MXEP

Littelfuse Cartridge Fuses 250V .5A Fast Acting
Stock : 1

Hot 0235.500MXP electronic component of Littelfuse 0235.500MXP

500 mA 250 V AC DC Fuse Cartridge, Glass Holder 5mm x 20mm
Stock : 1

0218.032HXP electronic component of Littelfuse 0218.032HXP

Cartridge Fuses 250V .032A Time Lag (Slo-Blo)
Stock : 1

0229003.HXSP electronic component of Littelfuse 0229003.HXSP

3 A 250 V AC 125 V DC Fuse Cartridge, Glass Requires Holder 2AG, 5mm x 15mm
Stock : 130

01070002Z electronic component of Littelfuse 01070002Z

Littelfuse Fuse Clips Clip 916 Dia
Stock : 1

022903.5MXP electronic component of Littelfuse 022903.5MXP

Cartridge Fuses 3.5A 250V Tube,4.2x14.1mm RoHS
Stock : 1

02292.25HXP electronic component of Littelfuse 02292.25HXP

2.25 A 250 V AC 125 V DC Fuse Cartridge, Glass Holder 2AG, 5mm x 15mm
Stock : 0

0235.200MXP electronic component of Littelfuse 0235.200MXP

Cartridge Fuses 250V .2A Fast Acting
Stock : 1

0235002.VXP electronic component of Littelfuse 0235002.VXP

Cartridge Fuses 250V 5X20mm P 2AMP
Stock : 0

00713200 electronic component of Littelfuse 00713200

Pushbutton Switches Plunger Switch 2-Way N.C.
Stock : 0

Image Description
AZ2510P2-1A-24D electronic component of Zettler AZ2510P2-1A-24D

Electromechanical Relay SPST-N
Stock : 1

RPM12B7 electronic component of Schneider RPM12B7

Industrial Relays PLUG-IN RELAY 250V 1 5A RPM
Stock : 0

2966919 electronic component of Phoenix Contact 2966919

Industrial Relays PLC-RSC- 12DC/21AU RELAY PN 651-2961163
Stock : 1

RSB2A080RD electronic component of Schneider RSB2A080RD

Industrial Relays PLUG-IN RELAY 250VAC 8A RSB
Stock : 0

RXM2AB3F7 electronic component of Schneider RXM2AB3F7

Industrial Relays Plug-in Relay 250V 10A RXM+LED NO MAN
Stock : 1

2902955 electronic component of Phoenix Contact 2902955

Industrial Relays PLC-RSC-24DC/21 ATEX
Stock : 1

2966223 electronic component of Phoenix Contact 2966223

Industrial Relays PLC-RSC-24DC/1/SEN
Stock : 10000

R4N-2014-23-5012-WT electronic component of Relpol R4N-2014-23-5012-WT

Relay: electromagnetic; 4PDT; Ucoil:12VAC; 6A/250VAC; 6A/24VDC
Stock : 0

RM84-2012-25-5230 electronic component of Altech RM84-2012-25-5230

Industrial Relays Miniature relay, DPDT
Stock : 1

RM84-2012-25-5110 electronic component of Altech RM84-2012-25-5110

Industrial Relays relay 110VAC coil 50/60HZ
Stock : 0

Protection Relays Motor and Pump Protection 111-INSIDER-P / 231-INSIDER-P Single-Phase Pump Monitor Description The Littelfuse 111-Insider-P single-phase products fit inside and hp, 115 V control boxes and the 231-Insider-P fits inside , , , and 1 hp, 230 V control boxes. Both models are designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid-cycle, overvoltage, and undervoltage conditions. A calibration adjustment allows the Insider to be calibrated to your specific pumping applications, thereby reducing the possibility of false or nuisance tripping. A unique microcontroller-based voltage and current-sensing circuit constantly monitors the incoming power for fluctuations, overcurrent, and undercurrent. When an abnormality, such as loss of suction is detected, the product deactivates its output relay and directly disconnects the pump motor. The unit then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the unit reactivates its output relay and turns the pump back on. By leaving the restart delay knob in the reset position, the unit will operate in manual reset mode. The Insider communicates with a hand-held diagnostics tool called the Informer (sold separately). The Informer displays parameters including calibration points, trip points, run time and last faults. An IR Kit-12 (12 fiber optic kit) is included with each Wiring Diagrams Insider, allowing the Informer to access these parameters even when the Insider is enclosed in a control box. This is valuable for See next page. troubleshooting the pump while it is running. NOTE: The 111/231-Insider-P models have a sensitivity adjustment for the dry-well trip point. After calibration is done, you can adjust the sensitivity for the dry-well/dead-head trip point from 70-90 % of the full load. This makes the unit even more adaptable to varying pumping applications. If you have a very low producing well, you increase the sensitivity closer to the 90 % mark, or if you have a very heavy producing well, you would decrease the sensitivity around Accessories the 70 % mark. Informer A hand-held diagnostic tool that uses an infrared receiver to access information which can be Features & Benefits helpful for troubleshooting the system. Includes the Informer IR Kit-12 FEATURES BENEFITS Informer IR Kit-12 Proprietary Constant monitoring of voltage and current protects microcontroller pumps from dry-well, dead-head, jammed impeller, 12 infrared adapter cable attaches to the face of based circuitry rapid cycling, and voltage faults the unit to provide remote diagnostics without opening the panel. Included with the Informer Allows user to adjust the current sensitivity for the Onboard sensitivity dry-well / dead-head trip point from 70 % - 90 % of adjustment the full load. Ordering Information Allows user to select well recovery time delay after a Adjustable restart delay dry-well condition occurs, or to select manual reset MODEL VOLTAGE DESCRIPTION Used with the Informer, allows user to see stored Built in IR faults, run time, and also troubleshoot the pump while communications link its running 111-Insider-P 115 V ac - hp, includes IR Kit-12 LED indication Provides status and diagnostics for troubleshooting 231-Insider-P 230 V ac - 1 hp, includes IR Kit-12 *Pentek, Franklin, Grundfos, Flowise Pro, and Flint and Walling are trademarks of their respective owners. 2019 Littelfuse, Inc. Rev: 2-C-042619 www.littelfuse.com/111insiderp-231insiderpProtection Relays Motor and Pump Protection 111-INSIDER-P / 231-INSIDER-P Input Characteristics Specifications Supply Voltage Functional Specifications 111-Insider-P 115 V ac Adjustments/Settings 231-Insider-P 230 V ac Overcurrent 125 % of calibration point Load Range Underload (dry-well) Adjustable (70 to 90 % of calibrated run power) 111-Insider-P hp Overvoltage 231-Insider-P 1 hp 111-Insider-P 132.5 V ac Frequency 50/60 Hz (Note: 50 Hz will increase all 231-Insider-P 265 V ac delay timers by 20 %) Undervoltage Output Characteristics 111-Insider-P 95 V ac Output Contact Rating-SPST 231-Insider-P 190 V ac 111-Insider-P hp 120 V ac (17 A max.) Number of restarts allowed 231-Insider-P 1 hp 240 V ac (17 A max.) in a 60-sec. period General Characteristics (rapid-cycling) 4 Operating Temperature -40 C to 55 C (-40 F to 131 F) Trip Delay Times Maximum Input Power 5 W Overcurrent 5 seconds Safety Marks Dry-well 4 seconds cURus* UL 508, C22.2 No. 14 Restart Delay Times Weight 10 oz. Over/Undervoltage 2 seconds Mounting Methods Inside a Pentek*, Franklin*, CentriPro*, All other faults Manual, 2-225 minutes Grundfos* (mfg after mid-2014), Flowise Pro* and Flint and Walling* control box **The 111-Insider-P and 231-Insider-P are agency approved type 3R control boxes when installed as described in the installation instructions. The 111-Insider-P and 231-Insider-P are not intended to provide overload protection, and should be used with thermally or impedance protected motors only. Wiring Diagrams PENTEK* CONTROL BOX WIRING DIAGRAM FRANKLIN* CONTROL BOX WIRING DIAGRAM BLUE MODEL 231/111 ORANGE INSIDER-P 111/231 BLUE INSIDER-P SOLID-STATE SWITCH BLK RED YEL B(MAIN) Y(COMM) R(START) L2 L1 111-Insider-P/231-Insider-P FIGURE 5: Pentek Control Box with the PumpSaver Plus Installed in Franklin Control Box 2019 Littelfuse, Inc. Rev: 2-C-042619 www.littelfuse.com/111insiderp-231insiderp

Tariff Desc

8536.49.00 TC17103979 RELAYS PRINTED CIRCUIT BOARD

8536.41 TC8909066 RELAYS having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mmx30mmx27mm

8536.49.00 TC9613322 RELAYS low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24mm
(b) height NOT exceeding 35mm and having a continuous current rating NOT less than 8AAC

8536.49 TC8906734 RELAYS having ALL of the following:
(a) one, two or three contacts
(b) maximum continuous contact current rating of NOT less than 15A
(c) maximum contact voltage rating of NOT less than 380V
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC1122469 RELAYS having an operating voltage NOT exceeding 250volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC8534635 RELAYS cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5A (AC or DC);
(b) switching voltage NOT exceeding 250V (AC or DC);
(c) body dimensions NOT exceeding 31mm x36mm x19mm

8536.49 TC8633667 RELAYS vacuum, hermetically sealed

8536.41.00 TC19144923 RELAYS SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.49 TC 8532678 CONTACTORS, having BOTH of the following:
(a) normally closed main poles;
(b) DC rated current 9 A or greater

8536.49.00 TC 1312158 CONTACTORS, single OR multi-pole, for a voltage NOT exceeding 1000V

8538.90.90 08 .. For programmable controllers Other Free
C&K Aerospace
HAMLIN
Hamlin Littelfuse
Hamlin / Littelfuse
Hamlin Inc
Hartland Controls / Littelfuse
LF
LF7
Littelfuse Teccor Sidactor Product
Littelfuse Wickmann Brand
Littelfuse / US Sensor
Littelfuse Inc
Littelfuse Inc.
LITTELFUSE SEMITRON
LITTELFUSE WICKMANN
LITTELFUSE, INC.
Little Fuse / Wickmann
Littlefuse
SSAC
SSAC Relays
TE Connectivity / Circuit Protection
WICKMANN USA

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted