Product Information

AT20B5

AT20B5 electronic component of Lem

Datasheet
CURRENT TRANSDUCER, 20A, VOLTAGE O/P

Manufacturer: Lem
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 87.3832 ea
Line Total: USD 87.38

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 24 May to Thu. 30 May

MOQ : 1
Multiples : 1

Stock Image

AT20B5
Lem

1 : USD 83.0435

     
Manufacturer
Product Category
Sensor Output
Supply Voltage Dc Min
Supply Voltage Dc Max
Current Measuring Range Dc
Current Measuring Range Ac
Response Time
Accuracy
Product Range
Svhc
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
CKSR 25-NP electronic component of Lem CKSR 25-NP

SENSOR CURRENT FLUX 25A AC/DC
Stock : 1

CAS 50-NP electronic component of Lem CAS 50-NP

SENSOR CURRENT FLUX 50A AC/DC
Stock : 2

AT150B420L electronic component of Lem AT150B420L

CURRENT TRANSDUCER, 150A, CURRENT O/P
Stock : 0

AT100B420L electronic component of Lem AT100B420L

CURRENT TRANSDUCER, 100A, CURRENT O/P
Stock : 0

DHR 600 C10 electronic component of Lem DHR 600 C10

Current Transducer,600A, 0-10V O/P
Stock : 0

DHR 1000 C420 electronic component of Lem DHR 1000 C420

Current Transducer,1000A, 4-20Ma O/P
Stock : 0

AT20B420L electronic component of Lem AT20B420L

CURRENT TRANSDUCER, 20A, CURRENT O/P
Stock : 0

AT50B10 electronic component of Lem AT50B10

CURRENT TRANSDUCER, 50A, VOLTAGE O/P
Stock : 0

HAS300-S electronic component of Lem HAS300-S

Current Sensors Through Hole RoHS
Stock : 1

LAH100-P electronic component of Lem LAH100-P

Current Sensors Through Hole RoHS
Stock : 0

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

AC Current transducer AT-B5 I = 5 .. 150 A AC Current transducer AT-B5 I = 5 .. 150 A PN PN Split-core transducer for the electronic measurement of AC waveform Split-core transducer for the electronic measurement of AC waveform currents, with galvanic isolation between the primary circuit (power) currents, with galvanic isolation between the primary circuit (power) and the and the secondary circuit (measurement). 0-5V DC voltage output secondary circuit (measurement). 0-5V DC voltage output proportional to proportional to the RMS value of the primary current. the RMS value of the primary current. Electrical data Features Primary nominal current rms Output voltage Type I (A.t.Rms) V (V DC) PN OUT Electrical data Features RMS (average) output 5 0-5 AT 5 B5 0-5V DC voltage output 10 0-5 AT 10 B5 Primary nominal Output voltage Type RMS (average) output Split-core type 20 0-5 AT 20 B5 current rms 0-5V DC voltage output 50 0-5 AT 50 B5 16 mm sensing aperture for non- 100 0-5 AT 100 B5 I (A.t.Rms) V (V DC) Split-core type PN OUT contact measurement 150 0-5 AT 150 B5 5 0-5 AT 5 B5 16 mm sensing aperture for Terminal output R Load resistance 1 MW 10 0-5 AT 10 B5 L non-contact measurement Isolated plastic case recognized V Supply voltage self-powered 20 C 0-5 AT 20 B5 Terminal output according to UL 94-V0. V Output clamping voltage 7.5 V SZ 50 0-5 AT 50 B5 Isolated plastic case recognized Overload capability - continuous 120 % of I P PN 100 0-5 AT 100 B5 according to UL 94-V0. - 1 min 150 % of I Advantages PN 150 0-5 AT 150 B5 Advantages High isolation between primary and R Load resistance 1 MW L secondary circuits Performance data V Supply voltage self-powered High isolation between primary C Compact case V Output clamping voltage 7.5 V X Accuracy I , T = 25C (excluding offset) < 2 % of I and secondary circuits SZ PN A PN Cost-effective solution Overload capability - continuous 120 % of I Linearity error < 0.5 % Compact case P L PN Easy installation t Response time to 90% of I step < 300 m s - 1 min 150 % of I r P Cost-effective solution PN BW Frequency bandwidth 50/60 Hz Easy installation Applications Performance data Applications Automation and Supervision General data Current measurement for process X Accuracy I , T = 25C (excluding offset) < 1.5 % of I PN A PN Automation and Supervision T Ambient operating temperature - 20 .. + 60 C A regulation by distributed PLCs or e Linearity error < 0.5 % of I L PN Current measurement for process T Ambient storage temperature - 20 .. + 85 C S remote control (e.g. SCADA t Response time to 90% of I step < 300 ms r m Mass PN 90 g regulation by distributed PLCs software) BW Frequency bandwidth 50/60 Hz IPxx Protection degree IP40 or remote control (e.g. SCADA Safety and Condition Monitoring software) Load monitoring for protection General data Safety and Condition systems and predictive Monitoring maintenance (e.g. conveyers, T Ambient operating temperature - 20 .. + 60 C A Load monitoring for protection pumps or HVAC motors) T Ambient storage temperature - 20 .. + 85 C S systems and predictive m Mass 90 g maintenance (e.g. conveyers, Application domain IPxx Protection degree IP40 pumps or HVAC motors) Energy and Automation Application domain Energy and Automation Page 1/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 071115/4 www.lem.com Page 1/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 090609/6 www.lem.comCurrent Transducer AT-B5 Isolation characteristics 1) V Rated isolation voltage rms 300 V b with IEC 61010-1 standards and following conditions: - Reinforced isolation - Over voltage category CAT III - Pollution degree PD2 - Heterogeneous field 2) V Rms voltage for AC isolation test , 50Hz, 1min. 3.5 kV d dCp Creepage distance 6 mm dCl Clearance distance 6 mm CTI Comparative tracking index (Group I) 600 1) Notes: If insulated cable is used for the primary circuit, the isolation voltage category can be improved according to the primary cable insulation category (please refer to the cable manufacturers indications) 2) between primary (completely filling the hole) and secondary. Safety and warning notes In order to guarantee safe operation of the transducer and to be able to make proper use of all features and functions, please read these instructions thoroughly Safe operation can only be guaranteed if the transducer is used for the purpose it has been designed for and within the limits of the technical specifications. Ensure you get up-to-date technical information that can be found in the latest associated datasheet under www.lem.com. Caution Risk of danger Ignoring the warnings can lead to serious injury and/or cause damage The electric measuring transducer may only be installed and put into operation by qualified personnel that have rceived an appropriate training. The corresponding national regulations shall be observed during installation and operation of the transducer and any electrical conductor. The transducer shall be used in electric/electronic equipment with respect to applicable standards and safety rquirements and in accordance with all the related systems and components manufacturers operating instructions. Caution Risk of electrical shock When operating the transducer, certain parts of the module may carry hazardous live voltage (e.g. primary conductor, power supply). The user shall ensure to take all measures necessary to protect against electrical shock. The transducer is a built-in device containing conducting parts that shall not be accessible after installation. A protective enclosure or additional insulation barrier may be necessary. The transducer shall not be put into operation if the jaw opening is open (split core version) or the installation is not completed. Installation and maintenance shall be done with the main power supply disconnected except if there are no hazardous live parts in or in close proximity to the system and if the applicable national regulations are fully observed. Safe and trouble-free operation of this transducer can only be guaranteed if transport, storage and installation are carried out correctly and operation and maintenance are carried out with care. Page 2/3 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. 090609/6 www.lem.com

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted