Product Information

SV225

SV225 electronic component of Fluke

Datasheet
Test Connectors STRAY VOLTAGE ELIMINATOR

Manufacturer: Fluke
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 138.9018 ea
Line Total: USD 138.9

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - Global Stock


Ships to you between Mon. 06 May to Fri. 10 May

MOQ : 1
Multiples : 1

Stock Image

SV225
Fluke

1 : USD 133.5594
3 : USD 128.2165
5 : USD 122.8736

0 - Global Stock


Ships to you between Fri. 10 May to Tue. 14 May


Multiples : 1

Stock Image

SV225
Fluke


     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Brand
Product Type
Factory Pack Quantity :
Subcategory
Hts Code
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
1273185 electronic component of Fluke 1273185

HEAVY DUTY TEST LEAD SET
Stock : 1

1547885 electronic component of Fluke 1547885

Fluke METER CASE,LEATHER,LARGE
Stock : 1

1576734 electronic component of Fluke 1576734

Fluke FLUKEVIEW FORMS WITH CABLE FOR USE WITH 18X, 28X DMMS
Stock : 1

1610115 electronic component of Fluke 1610115

AC280 Suregrip Hook Clips
Stock : 0

1LAC-A electronic component of Fluke 1LAC-A

LOW VOLTAGE DETECTOR AMERICAS PACIFIC AVAILABLE IN 12 PA
Stock : 0

114519 electronic component of Fluke 114519

AC/DC CURRENT PROBE, SCOPEMETER(R)
Stock : 1

1503 electronic component of Fluke 1503

Insulation Resistance Testers
Stock : 0

1630 electronic component of Fluke 1630

Fluke 1630 Earth Ground Clamp Meter
Stock : 1

190-102/AM electronic component of Fluke 190-102/AM

Oscilloscope (DSO) + DMM - 2 Ch, 100 MHz -- 6" Color TFT LCD -- 8 bit, 1.25Gs/S Portable Scopemeter® ...
Stock : 1

1623-2-KIT electronic component of Fluke 1623-2-KIT

Basic GEO Earth Ground Tester Kit
Stock : 1

Image Description
4247 electronic component of Pomona 4247

Aluminum Flange Mount Die Cast Aluminum Box
Stock : 2

BF-3 electronic component of Omron BF-3

Test Connectors ELECTRODE HOLDER
Stock : 5

3743 electronic component of Pomona 3743

UNPAINTED SHIELDED HOUSING, 6 HIGH WITH CARD GUIDES
Stock : 1

CS20MA electronic component of Fluke CS20MA

Test Connectors CURRENT SHUNT 4-20
Stock : 1

3306 electronic component of Pomona 3306

Test Connectors SHIELDED BOX
Stock : 1

73104-0 electronic component of Pomona 73104-0

Test Connectors BLK DIY INS BNC M CONNECTOR 50 OHM
Stock : 4

73104-6 electronic component of Pomona 73104-6

Test Connectors BLUE DIY INS BNC M CONNECTOR 50 OHM
Stock : 2

CT3881-0 electronic component of Cal Test CT3881-0

Test Connectors 6.6mm MAGNETIC CONN 4mm RT ANGLE BLACK
Stock : 0

BF-5 electronic component of Omron BF-5

Test Connectors ELECTRODE HOLDER
Stock : 1

MM126525 electronic component of Murata MM126525

Test Connectors
Stock : 2

CATIV 600 V Do not apply more than the rated voltage, as marked on the multimeter or in the Adapter specifications (whichever is lower) between the terminals, or between any terminal and earth ground. Before each use, inspect test leads for damage and check for continuity. Do not use Instruction Sheet leads that are damaged or show high resistance. Look for cracks or missing plastic on the lead housing or cable insulation. Adhere to local and national safety codes. Individual protective equipment must be used SV225 to prevent shock and injury. If the equipment is used in a manner not specified by the manufacturer, the protection Stray Voltage Eliminator provided by the equipment may be impaired. The Adapter is specified for CAT III 1000V/CAT IV 600V per EN61010. CAT III equipment is designed to protect against transients in equipment in fixed- equipment installations, such as distribution panels, feeders and short branch circuits, and lighting systems in large buildings. CAT IV equipment is designed to protect against transients from the primary supply level, such as an electricity meter or an overhead or underground utility service. Symbols The following symbols appear on the Adapter or in this instruction sheet. T Product is protected by double insulation. Introduction The SV225 Stray Voltage Eliminator (hereafter referred to as Risk of Danger. Important information. See the Adapter) is a digital multimeter accessory that allows W Instruction Sheet. measurements in circuits which may be subject to stray voltages encountered from adjacent-energized wiring. The Adapter provides an approximate 3,000 e load to the X Hazardous voltage. measured circuit, desensitizing the meter to low energy, spurious sources of interference. The Adapter is only used for voltage measurements. When used with a compatible digital Conforms to relevant Australian standards. N10140 multimeter, it can be determined whether the circuits under test are energized or not. P Conforms to relevant European Union directives. Safety Information XW Read First: Safety Information Specifications To avoid possible electric shock or personal injury: Voltages up to 1000 volts continuous can be safely applied to the Adapter without damage. Read the operating instructions before use and follow all safety instructions. Operation Temperature Use caution when working with voltages -20 C to +55 C (-40 F to 131 F) above 60 V dc or 30 V ac. Such voltages pose Altitude a shock hazard. 2,000 Meters Operating Before testing the desired circuit, ensure that Humidity the multimeter and Adapter are functioning 90 % at 0 to 35 C (32 F to 95 F), 70 % at 35 to 55 C properly by testing a known live circuit. A de- (95 F to 131 F) energized circuit will be indicated on the Nominal Resistance multimeter display as a reading near zero 3,000 25 C (77 F) volts. When using the Adapter to eliminate stray or Instrument Compatibility ghost voltage, the Adapter has a low input The Adapter is for use with any high-impedance digital impedance, nominally 3,000 . This low multimeter ( 1 M) which accepts 4 mm safety-shrouded impedance places a moderate load on the banana plugs and with any test leads using the same safety- circuit under test. Do not use the Adapter to shrouded banana plugs. The Adapter is compatible with the measure live voltages in circuits that could be following Fluke digital multimeters and testers: damaged by a 3 k load. Fluke 27 70 Series 80 Series Fluke-110 Series PN 2429231 March 2005 170 Series 2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 180 Series All product names are trademarks of their respective companies. T5 Series testers Operation Contacting Fluke To use the Adapter, do the following: To contact Fluke, call one of the following telephone numbers: 1. Plug the Adapter into the digital multimeters V/ and USA: 1-888-44-FLUKE (1-888-443-5853) COMMON input jacks. Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 2. Plug the test leads into the Adapter input jacks observing Japan: +81-3-3434-0181 the proper polarity (red lead to red jack, black lead to black Singapore: +65-738-5655 jack). Make sure the leads and Adapter are fully Anywhere in the world: +1-425-446-5500 connected to the instrument. USA Service: 1-888-99-FLUKE (1-888-993-5853) 3. Turn the multimeters function switch to the Volts AC measurement function. Or, visit Fluke s Web site at www.fluke.com. To register your product, visit register.fluke.com XW Warning To avoid possible electric shock or personal injury, before testing the desired circuit, ensure LIMITED WARRANTY AND LIMITATION OF LIABILITY that the multimeter and Adapter are functioning This Fluke product will be free from defects in material and properly by testing a known live circuit. A de- workmanship for one year from the date of purchase. This warranty energized circuit will be indicated on the does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of multimeter display as a reading near zero volts. operation or handling. Resellers are not authorized to extend any other 4. After determining the circuit under test is de-energized, warranty on Flukes behalf. To obtain service during the warranty retest the known live circuit again to insure the multimeter period, contact your nearest Fluke authorized service center to obtain and Adapter are still working properly. return authorization information, then send the product to that Service Center with a description of the problem. Note THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER Most digital multimeters never display a zero-volt WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR reading for a de-energized circuit. A small residual PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LIABLE reading may always be present. FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL The example in Figure 1 shows a reading of 13.2 DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation millivolts AC which is very close to a zero-volt reading. th of an implied warranty or of incidental or consequential damages, this 1 millivolt is equal to .001 volts or 1/1000 of a volt. limitation of liability may not apply to you. Fluke Corporation Fluke Europe B.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 BD Eindhoven U.S.A. The Netherlands 11/99 Figure 1. Residual Voltage Reading Maintenance Cleaning W Caution To avoid damaging the Adapter, do not use abrasives or solvents for cleaning. Periodically wipe the Adapter with a damp cloth and mild detergent.

Tariff Desc

8536.90 PROBES, multimeter Op. 20.03.1984 Dec. 20.03.1984 - TC 8342739

8536.69.10 62 Plugs and sockets for co-axial cables or printed circuits Free

8536.69.90 CONNECTORS, ELECTRICAL, being ANY of the following:
(a) plugs;
(b) sockets;
(c) adaptors
TC 1225594

8536.69.90 SOCKETS, being ANY of the following:
(a) single pin, NOT exceeding 3.5 mm;
(b) micro, single pin, 2 mm;
(c) DC power connector, 2.1 mm OR 2.5 mm;
(d) 9 pin OR 15 pin, sub D;
(e) 2, 4 OR 8 pole microphone connector;
(f) 2, 3, 5, 6, 7, 8 OR 13 pin DIN;
(g) 16, 20, 26, 34, 40 OR 50 way dual in line crimp-on
TC 9900883

8536.69 JACKS, phono, RCA Type
TC 8438480

8536.69.90 CONNECTORS, electrical, incorporating twist locking mechanism
TC 9703905

8536.70.90 CONNECTORS, OPTICAL Op. 12.06.2007 FIBRE
TC 0708845

8536.90.90 LUGS, being solderable, copper connectors
TC 0613954

8535.90.00 CRIMPING TERMINALS, having bell-mouth OR flared cable entry
TC 9504891
FLUKE CALIBRATION
Fluke Electronics
FLUKE NETWORKS

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted