High Performance Thermal-Magnetic Circuit Breakers 410/520/530-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism and toggle actuation (S-type TM CBE to EN 60 934 also to EN 60 947). Designed for rail, panel or surface mounting. Available with a choice of characteristic curves and optional auxiliary contacts. Typical applications Motors, generators, transformers, thyristors and silicon rectifiers. 1 Interrupting capacity to IEC 60947/EN 60947 410-... 530-... AC voltage Number Voltage Interrupting Power Interrupting Power factor Technical data of poles rating capacity I factor capacity I N N I I N 12...125 A N 7 + 10 A For further details please see: www.e-t-a.de/ti e 1 AC 240 V 5,000 A cos = 0.7 3,500 A cos = 0.8 Voltage rating AC 240 V 3 AC 415 V 3 AC 500 V 2 AC 240 V 8,000 A cos = 0.7 6,000 A cos = 0.7 DC 110 V Current rating range 3 3 AC 415 V 5,000 A cos = 0.7 3,000 A cos = 0.85 curves 01, 02, 04, 05: 10...125 A (EN 60947) DC voltage curves B3, C3, 01: 7...100 A (EN 60898) Number Voltage Interrupting Time Interrupting Time con- Auxiliary circuit 6 A, AC 240 V or DC 28 V of poles rating capacity I constant capacity I stant N N 1 A, DC 110 V I I N 12...125 A N 7 + 10 A Typical life 10,000 operations at 1 x I N 1 DC 110 V 3,000 A 13 ms 3,000 A L/R = 5 ms 20,000 operations mechanical 1 DC 110 V 5,000 A 5 ms Ambient temperature -40...+60 C (-40...+140 F) Insulation co-ordination rated impulse pollution 2 DC 110 V 5,000 A 13 ms 3,000 A L/R = 5 ms (IEC 60664 and 60664A) withstand voltage degree 2 DC 110 V 10,000 A 0 ms 6 kV 3 Dielectric strength (IEC 60664 and 60664A) test voltage Standard current ratings and typical internal resistance values operating area AC 3,300 V pole/pole AC 3,300 V main circuit/aux.circuit AC 2,200 V Curves 01, 02, 04, 05: Curves B3, C3: aux. circuit 11-12/13-14 AC 1,000 V Insulation resistance > 100 M (DC 500 V) Current Internal resistance Current Internal resistance rating (A) () per pole rating (A) () per pole Degree ef protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 10 0.033 7 0.033 Vibration 16 0.015 10 0.015 curves 02, 04, 05, B3, C3: 4 g (60-500 Hz), 0.30 mm (10-60 Hz) curve 01: 3 g (60-500 Hz), 0.23 mm (10-60 Hz) 20 0.010 12 0.015 to IEC 60068-2-6, test Fc 25 0.0062 16 0.010 10 frequency cycles/axis 32 0.0039 20 0.0062 Shock curves 02, 04, 05, B3, C3: 50 g (11 ms) directions 1, 2, 3, 4, 5 40 0.0031 25 0.0039 30 g in direction 6 50 0.0022 32 0.0031 curve 01: 30 g (11 ms) in directions 1, 2, 3, 4, 5 20 g in direction 6 63 0.002 40 0.0022 to IEC 60068-27, test Ea 80 0.002 50 0.002 Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka 90 0.002 63 0.002 Humidity 240 hours at 95 % RH 100 0.002 80 0.002 to IEC 60068-2-3, test Ca 125 0.002 100 0.002 Mass 410 (1-pole): approx. 290 g 520 (2-pole): approx. 580 g 530 (3-pole): approx. 870 g Approvals Authority Standard Rated voltage Current ratings UL UL 1077 AC 277 V 7...125 A (type 520) C22.2 No 235 1948 www.e-t-a.de 126 High Performance Thermal-Magnetic Circuit Breakers 410/520/530-... Ordering information Dimensions Type No. 410 single pole (ratings > 125 A: suffix 17015 - parallel connection) 520 double pole 530 three pole ON OFF Terminal design - main terminals K screw terminals 10-32 A pressure plate B5-DIN 46288 (curves B3/C3, 7-25 A) 40-63 A pressure plate B6-DIN 46288 (curves B3/C3, 32-63 A) Si terminals M3.5 80-125 A terminal screw DIN 46206, sheet 2, form 1, M6 thread 1 N/C Mounting 1 N/O 1 surface mounting 2 rail mounting (DIN EN 50022-35x7.5) or panel mounting 4 panel mounting with cylinder head screw M3.5 1 Magnetic trip curves 01 2.1-3 x I AC (thyristor and rectifier protection) N 02 7-10 x I AC (motor and generator protection to EN 60947) N 92 16 04 3.5-5 x I AC (cable protection to EN 60947) N 3.62 .630 05 4-6 x I AC (generator protection to EN 60947) N symmetrical rail DIN EN 50022-35x7.5 B3 3-5 x I AC (cable protection to EN 60898) N G profile rail DIN EN 50035-G32 (not shown) C3 5-10 x I AC (cable protection to EN 60898) N M3.5 - thread max. 9 mm (.354 in.) deep Auxiliary contacts optional (terminals M3.5) tightening torque max. 0.8 N D Si one each N/O and N/C contact 45 Si1 one N/C (11,12) 1.77 Current ratings 35 E 7...125 A 1.38 520 - K - 1 - 01 - ... - 10 A ordering example pole 1 Please be informed that we have minimum ordering quantities to be observed. pole 2 B The exact number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. pole 3 Mounting methods Current Dimensions mm/in. Terminal Cross section (see DIN 46288) Max. Surface mounting rail mounting rating tightening with 1 or 2 equal with 2 different B CD E torque -1 (DIN EN 50 022-35x7,5) conductors conductors pressure -2 2 2 13 114 7 2.5 mm to 2.5 mm to plate B5 2.0 Nm 32 A M5 2 2 .512 4.49 .276 10 mm 10 mm DIN 46288 2 2 pressure 2 4 mm and 6 mm 15.4 120 9 4 mm to plate B6 63 A M6 2 or 2.5 Nm .606 4.72 .354 16 mm 2 2 DIN 46288 6 mm to 16 mm 15.4 120 9 terminal 125 A M6 2.5 Nm .606 4.72 .354 screw panel mounting surface mounting -4 14.6 .575 monting holes 35 1.38 20 .787 3.7 22 4.6 .146 .866 .181 mm This is a metric design and millimeter dimensions take precedence ( ) inch 2 www.e-t-a.de 1948 26 66 97 2.60 3.82 106 44 4.17 1.73 22 41 .866 1.64 3 6 .118 .236 71.5 2.82 90.5 3.56 4.6 +1 44 .181 +.039 1.73 +0,5 22 +.020 .866 C 19 .748 type 530 4 type 520 type 410 .157