Thermal Overcurrent Circuit Breaker 3130 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double pole version, protection on one pole only. Illumination is optional and there is a choice of rocker colours. Approved to CBE standard EN 60934 (IEC 60934). Typical applications Motors, transformers, solenoids, household and office machines, electrical tools, mobile homes, boating, construction vehicles, medical equipment 1 to EN 60601. 3130 1-pole 3-pole Standard current ratings and typical internal resistance values Technical data Current Internal resistance Current Internal resistance rating (A) per pole () rating (A) per pole () For further details please see chapter: Technical Information Voltage rating AC 240 V 3 AC 415 V DC 50 V 0.1 94 4 0.0435 (UL: AC 250 V 3 AC 250 V DC 50 V) 0.2 24 5 0.0325 Current ratings 0.1...20 A 1-pole 0.1...16 A 2- and 3-pole 0.3 12 6 0.0215 Typical life 1-pole 0.4 5.30 7 0.0165 AC 240 V: 0.1...20 A 30,000 operations at 1 x I , inductive N DC 50 V: 0.1...4 A 30,000 operations at 1 x I , inductive N 0.5 4.20 8 0.0165 4.5...16 A 30,000 operations at 1 x I , resistive N 0.8 1.50 10 < 0.02 DC 28 V: 0.1...20 A 30,000 operations at 1 x I , inductive N 2-pole 1 0.9 12 < 0.02 AC 240 V: 0.1...16 A 50,000 operations at 1 x I , inductive N DC 50 V: 0.1...16 A 50,000 operations at 1 x I , inductive 1.2 0.80 14 < 0.02 N 3-pole 1.5 0.45 15 < 0.02 3 AC 415 V: 0.1...16 A 30,000 operations at 1 x I , inductive N Ambient temperature -30...+60 C (-22...+140 F) 2 0.27 16 < 0.02 Insulation co-ordination rated impulse pollution 2.5 0.0785 18 < 0.02 (IEC 60664 and 60664 A) withstand voltage degree 2.5 kV 2 3 0.0595 20 < 0.02 reinforced insulation in operating area 3.5 0.0565 Dielectric strength (IEC 60664 and 60664A) test voltage operating area AC 3,000 V Illumination voltage/power consumption current path/current path AC 1,500 V Insulation resistance > 100 M (DC 500 V) operating voltage power consumption Interrupting capacity I 0.1...2 A 10 x I cn N 1-pole 2-/3-pole 2-/3-pole 2.5...20 A 150 A 1-pole 2.5...16 A 250 A 2-pole Y+R G 2.5...12 A 150 A 3-pole 12 V 9 mA 2 mA 3.5 mA 14 + 16 A 130 A 3-pole Interrupting capacity (UL 1077) 24 V 9 mA 2 mA 3.5 mA I U I 48 V 9 mA 2 mA 3.5 mA N N nc 1, 2-pole 0.1...16 A AC 250 V 3500 A 115 V < 1 mA 0.9 mA 2.8 mA 3-pole 0.1...12 A 3 AC 250 V 5000 A 230 V < 1 mA 0.9 mA 2.8 mA 1,2-pole 0.1...16 A DC 50 V 2000 A 400 V - 0.9 mA 2.8 mA Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration 5 g (57-500 Hz) 0.38 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis Shock 1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH, to IEC 60068-2-78, test Cab Mass approx. 45 g (three pole) approx. 31 g (double pole) approx. 17 g (single pole) 1815 www.e-t-a.de 1Thermal Overcurrent Circuit Breaker 3130 Ordering information - 1-pole Ordering information - multipole Type No. Type No. 3130 single pole thermal circuit breaker 3130 multipole thermal circuit breaker Mounting Mounting F snap in frame F snap in frame Frame Frame 1 standard 1 standard Number of poles A version for X3130 1 single pole, thermally protected Number of poles Frame mounting 2 2-pole thermally protected 0 panel thickness 1-2.5 mm (.039-.099 in) 3 3-pole thermally protected Terminal design 5 2-pole, 1-pole thermally protected P7 blade terminals DIN 46244-C-Ms-S (QC 2x.110) Frame mounting H7 for terminals 1.1, 2.1 3.1 terminal screws M 3.5 0 panel thickness 1-2.5 mm (.039-.099 in) 1 for terminals 1.2, 2.2, 3.2 blade terminals (QC 2x.110) A 2-pole, version for X3130 Characteristic curve Terminal design T1 thermal 1.05-1.4 I P7 blade terminals DIN 46244-C-Ms-S N Actuator style (characteristic curve T1) W rocker switch with marking I and O H7 for terminals 1.1, 2.1 3.1 terminal screws M 3.5 moulded in for terminals 1.2, 2.2, 3.2 blade terminals (QC 2x.110) Actuator colour Characteristic curve 01 Q black opaque without illumination T1 thermal 1.05-1.4 I N 02 Q white opaque without illumination Actuator style 04 Q red opaque without illumination W rocker switch with marking I and O 14 Q R red translucent with LED-illumination moulded in 15 Q Y orange translucent with Actuator colour LED-illumination 01 Q black opaque without illumination 19 Q G green translucent with 02 Q white opaque without illumination LED-illumination (DC only) 04 Q red opaque without illumination Illumination voltage range* 14 Q R red translucent with 2 10 - 14 V DC LED-illumination 3 20 - 28 V DC 15 Q Y orange translucent with 6 90 - 140 V AC LED-illumination 7 185 - 275 V AC 19 Q G green translucent with Current ratings LED-illumination 0,1...20 A Illumination voltage range* 2 10 - 14 V DC 3130 - F 1 1 0 - P7 T1 - W 14 Q R 3 - 5 A ordering example 3 20 - 28 V DC 6 90 - 140 V AC * N/A for non-illuminated version 7 185 - 275 V AC 8 320 - 450 V AC Current ratings 0,1...16 A Preferred types 3130 - F 1 3 0 - P7 T1 - W 14 Q R 7 - 5 A ordering example Preferred types Standard current ratings (A) * N/A for non-illuminated version 3130 1-pole 1 2 3 4 5 8 10 15 16 20 3130-F110-P7T1- x x x x x x x x x x W01Q- Approvals Authority Standard Rated voltage Current ratings AC 240 V 0.1 A20 A (single pole) VDE IEC/EN AC 240/415 V 0.1 A16 A (multipole) 60934 DC 50 V 0.1 A8 A (single pole) DC 50 V 0.1 A16 A (multipole) DC 28 V 0.1 A20 A (single pole) AC 250 V 0.1 A16 A (1 + 2 pole) UL UL 1077 AC 250 V 0.1 A12 A (3 pole) DC 50 V 0.1 A16 A (1 3 pole) AC 250 V 0.1 A16 A (1 + 2 pole) CSA C22.2 No AC 250 V 0.1 A12 A (3 pole) 235 DC 50 V 0.1 A16 A (1 3 pole) 2 www.e-t-a.de 1815