Product Information

W3G300-RQ30-43

W3G300-RQ30-43 electronic component of ebm papst

Datasheet
EC Fans EC Axial Fan, 300mm Round, 26VDC, 2640m3/h, 185W, 7A, 71dBA, 2850RPM, Ball

Manufacturer: ebm papst
Large
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 295.7512 ea
Line Total: USD 295.75

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Wed. 22 May to Tue. 28 May

MOQ : 1
Multiples : 1

Stock Image

W3G300-RQ30-43
ebm papst

1 : USD 295.7512
25 : USD 269.7192
50 : USD 267.6672
100 : USD 254.286
150 : USD 213.7104
500 : USD 201.4632

     
Manufacturer
Product Category
Type
Series
Product
Brand
Current Type
Product Type
Factory Pack Quantity :
Subcategory
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 32

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 1

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 0

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
AC8300H electronic component of ebm papst AC8300H

EC Fans EC Fan, 80x80x32mm, 115VAC, 47.1CFM, 8.3W, 48dBA, 5000RPM, Ball, ACmaxx
Stock : 40

ACI4410HHU electronic component of ebm papst ACI4410HHU

FAN AXIAL 119X38MM
Stock : 0

W3G200-HD23-10 electronic component of ebm papst W3G200-HD23-10

EC Fans EC Axial Fan, 225x225x80mm, 115VAC, 50/60Hz, 623CFM, 65W, 2900RPM, Ball Bearing
Stock : 3

W1G300-BB23-01 electronic component of ebm papst W1G300-BB23-01

EC Fans EC Axial Fan, 300mm Round, 115VAC, 35W, 1300RPM
Stock : 0

S1G200-CA91-02 electronic component of ebm papst S1G200-CA91-02

EC Fans EC Axial Fan, 200mm Round, 230VAC, Ball Bearing
Stock : 2

OA109EC-UR-1TB electronic component of Orion OA109EC-UR-1TB

EC Fans Electronically Commutated (EC) Fan, 120x38mm, Voltage Range 90-265VAC, 115/230 Universal Input, 106CFM, 4.9/5.2W, 43dBA, 3200RPM, Dual Ball Bearing, Terminals
Stock : 16

OA172EC-22-1WB electronic component of Orion OA172EC-22-1WB

EC Fans Electronically Commutated (EC) Fan, 172x150x51mm, 230VAC, 220CFM, 15W, 57dBA, 3000RPM, Dual Ball Bearing, 2 Wire Leads
Stock : 2

OA172EC-11-1TB electronic component of Orion OA172EC-11-1TB

EC Fans Electronically Commutated (EC) Fan, 172x150x51mm, 115VAC, 220CFM, 15W, 57dBA, 3000RPM, Dual Ball Bearing, Terminals
Stock : 0

3238.500 electronic component of Rittal 3238.500

Fan: EC; 200/240VAC; 55m3/h; 49dBA; IP54,IP56; Colour: white
Stock : 6

AC100NR electronic component of ebm papst AC100NR

EC Fans EC Tubeaxial Fan, 130x98.5mm 115VAC, 2.5W, 35dBA, IP44 Rated, ACmaxx Series
Stock : 5

W4D500-GM03-10 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 potentially hazardous situations and important safety regulations: 1.3 Basic safety rules 1 DANGER 1.4 Electrical voltage 1 Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with 1.5 Safety and protective functions 2 the measures is mandatory. 1.6 Mechanical movement 2 WARNING 1.7 Emission 2 Indicates a potentially hazardous situation which, if not avoided, 1.8 Hot surface 2 could result in death or serious injury. Exercise extreme 1.9 Transport 2 caution while working. 1.10 Storage 2 CAUTION 1.11 Disposal 2 Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. 2. PROPER USE 3 NOTE 3. TECHNICAL DATA 4 A potentially harmful situation can occur and, if not avoided, can lead to property damage. 3.1 Product drawing 4 3.2 Nominal data 5 1.2 Staff qualification 3.3 Data according to ErP directive 5 The device may only be transported, unpacked, installed, operated, 3.4 Technical features 5 maintained and otherwise used by qualified, trained and authorised technical staff. 3.5 Mounting data 5 Only authorised specialists are permitted to install the device, to carry 3.6 Transport and storage conditions 5 out a test run and to perform work on the electrical installation. 4. CONNECTION AND START-UP 6 1.3 Basic safety rules 4.1 Connecting the mechanical system 6 Any safety hazards stemming from the device must be re-evaluated 4.2 Connecting the electrical system 6 once it is installed in the end device. 4.3 Connection in terminal box 7 Observe the following when working on the unit: 4.4 Connection screen 8 Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 4.5 Open additional screwed cable glands 9 4.6 Checking the connections 9 1.4 Electrical voltage 4.7 Switch on device 9 Check the electrical equipment of the device at regular intervals, refer 4.8 Switching off the device 9 to chapter 5.2 Safety test. Replace loose connections and defective cables immediately. 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 10 CAUSES AND REMEDIES DANGER 5.1 Cleaning 10 Electrical load on the device Risk of electric shock 5.2 Safety test 10 Stand on a rubber mat if you are working on an electrically charged device. WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 10764-5-9970 Revision 83223 Release 2014-05-16 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsW4D500-GM03-10 Operating instructions CAUTION 1.7 Emission In the event of failure, there is electric voltage at the WARNING rotor and impeller Depending on the installation and operating conditions, The rotor and impeller are base insulated. a sound pressure level greater than 70 dB(A) may arise. Do not touch the rotor and impeller once they are installed. Danger of noise-induced hearing loss CAUTION Take appropriate technical safety measures. The motor restarts automatically when operating voltage Protect operating personnel with appropriate safety is applied, e.g. after a power failure. equipment, e.g. hearing protection. Danger of injury Also observe the requirements of local agencies. Keep out of the danger zone of the device. When working on the device, switch off the mains 1.8 Hot surface supply voltage and secure the latter from being switched on CAUTION again. High temperature at the motor housing Wait until the device stops. Danger of burn injuries Insert the brought-out thermal overload protector into the Ensure that sufficient protection against accidental contact is control circuit so that the cooled off motor does not switch on provided. independently after a fault. 1.9 Transport 1.5 Safety and protective functions NOTE DANGER Transport of device Missing safety device and non-functioning safety device Transport the device in its original packaging only. If there is no safety device, you could be seriously injured, for example if you reach into the running device or your hands are Secure the device so that it does not slip, e.g. by using a sucked into it. clamping strap. Operate the device only with a fixed and isolating safety 1.10 Storage protection and a fixed guard grille. The guard must withstand the kinetic energy of a fan blade Store the device, partially or fully assembled, in a dry and detaching at maximum speed. weatherproof manner in the original packing in a clean environment. The device is a built-in component. You, the owner/ Protect the device from environmental impacts and dirt until the final operator, are responsible for providing adequate protection for installation. the device. We recommend storing the device for a maximum up to one year to Shut down the device immediately if you detect a guarantee proper operation and longest possible service life. missing or ineffective protective feature. Even devices explicitly suited for outdoor use are to be stored as described prior to being commissioned. 1.6 Mechanical movement Maintain the storage temperature, see DANGER chapter 3.6 Transport and storage conditions. Rotating device Please make sure that all screwed cable glands are fitted with Body parts that come into contact with the rotor and impeller dummy plugs. can be injured. Secure the device against accidental contact. 1.11 Disposal Before working on the system/machine, wait until all When disposing of the device, please comply with all relevant parts have come to a standstill. requirements and regulations applicable in your country. WARNING Rotating device Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured. Do not wear any loose clothing or jewellery while working on rotating parts. Protect long hair by wearing a cap. Item no. 10764-5-9970 Revision 83223 Release 2014-05-16 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions

Tariff Desc

8414.59.90 FANS INCORPORATING BRUSHLESS MOTORS, having ANY of the following:
(a) DC powered;
Op. 19.10.2000 Dec. 05.01.2001 - TC 0008777
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted