Product Information

BD 5935.48 DC 24V

BD 5935.48   DC 24V electronic component of Dold & Soehne

Datasheet
RELAY, SAFETY, 3NO, SPST-NC, 250VAC, 5A

Manufacturer: Dold & Soehne
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 491.137 ea
Line Total: USD 491.14

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Thu. 09 May to Wed. 15 May

MOQ : 1
Multiples : 1

Stock Image

BD 5935.48 DC 24V
Dold & Soehne

1 : USD 491.137

     
Manufacturer
Product Category
Contact Form
Contact Termination
Coil Voltage
IP Rating
Product Range
Contact Current
Relay Mounting
Relay Terminals
Contact Voltage Ac Nom
Contact Voltage Dc Nom
Approvals Standards
Svhc
Approval Bodies
Coil Voltage Vac Nom
Coil Voltage Vdc Nom
Contact Current Ac Max
Contact Current Max
Contact Voltage Ac Max
External Depth
External Height
External Length / Height
External Width
Operating Temperature Max
Operating Temperature Min
Supply Frequency
Switch Current Max
Switching Current Max
Type
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
IK 8800.11 AC 50HZ 230V electronic component of Dold & Soehne IK 8800.11 AC 50HZ 230V

RELAY, SPDT, 230VAC, 16A
Stock : 0

MK 9163N.12/110 ATEX AC/DC 24V electronic component of Dold & Soehne MK 9163N.12/110 ATEX AC/DC 24V

RELAY, THERMISTOR, MOTOR PROTECTION
Stock : 0

MK 9151.11 2 - 450K - OHM DC 24V electronic component of Dold & Soehne MK 9151.11 2 - 450K - OHM DC 24V

RELAY, LEVEL SENSING
Stock : 0

MK 7850N.82/200  AC/DC12-240V electronic component of Dold & Soehne MK 7850N.82/200 AC/DC12-240V

TIME DELAY RELAY, DPDT, 300H, 230VAC
Stock : 0

BD 5936.17 AC 50/60HZ 230V electronic component of Dold & Soehne BD 5936.17 AC 50/60HZ 230V

RELAY, SAFETY, DPST-NO, NC, 230VAC, 5A
Stock : 0

BG 5924.48 AC/DC 24V electronic component of Dold & Soehne BG 5924.48 AC/DC 24V

RELAY, SAFETY, 3NO, SPST-NC, 230VAC, 5A
Stock : 0

BN 5983.53 DC 24V electronic component of Dold & Soehne BN 5983.53 DC 24V

RELAY, SAFETY, 3NO, SPST-NC, 230VAC, 5A
Stock : 0

KO4323.STS.0055684 electronic component of Dold & Soehne KO4323.STS.0055684

ENCLOSURE, 16TERMINALS
Stock : 0

BD 5987.02/001 DC  24V electronic component of Dold & Soehne BD 5987.02/001 DC 24V

RELAY, SAFETY, DPST, 230VAC, 5A
Stock : 0

IK 8701.12 AC 50HZ 230V electronic component of Dold & Soehne IK 8701.12 AC 50HZ 230V

RELAY, DPDT, 230VAC, 16A
Stock : 0

Image Description
C500CE241 electronic component of Omron C500CE241

Safety Relays 24PIN Con SOLDERTYPE
Stock : 1

2904951 electronic component of Phoenix Contact 2904951

Safety Relays PSR-MS25-1NO- 1DO-24DC-SC
Stock : 11

SP10-ETL01 electronic component of Omron SP10-ETL01

INPUT SIMULATOR
Stock : 1

56.OA03.3253C electronic component of Altech 56.OA03.3253C

Safety Relays OA5603,32V, 5NO/3NC
Stock : 1

YS1T-RHA38F21PD electronic component of Idec YS1T-RHA38F21PD

Electromechanical Relay DIN Rail Thermal Overload Relay
Stock : 1

SR6ZB024 electronic component of TE Connectivity SR6ZB024

TE Connectivity Schrack Safety Relays 4PST-NODPST-NC 8A 24VDC SAFETY RELAY
Stock : 1

SR6ZA730 electronic component of TE Connectivity SR6ZA730

RELAY, SAFETY, 3PST-NO, NC, 250VAC, 8A
Stock : 0

TK-E5-65-95 electronic component of Fuji TK-E5-65-95

Electromechanical Relay 5A (68x106x105)mm Bracket Thermal Overload Relay
Stock : 0

8951.2N electronic component of Altech 8951.2N

Safety Relays RM2G1, 1 Channel Safety relay
Stock : 1

J73KN-AM-22 electronic component of Omron J73KN-AM-22

Safety Relays Aux Contact Block 2NO+2NC
Stock : 0

Safety technique Emergency Stop module BD 5935 safemaster According to EU Directive for machines 98/37/EG According to IEC/EN 60204-1 Safety category 4 according to EN 954-1 Output: optionally 1 NO / 1 NC or 3 NO / 1 NC contacts Gold plated contacts to switch low loads (signal to PLC) 1- or 2-channel connection Line fault detection on ON pushbutton Operating state display LED display for channels 1 and 2 Removable terminal strips Overvoltage and short circuit protection 2 Wire connection: also 2 x 1,5 mm stranded ferruled (isolated), DIN 46 228-1/-2/-3/-4 or 2 2 x 2,5 mm stranded ferruled DIN 46 228-1/-2/-3 Optionally automatic ON function when the operating voltage is applied or activation via the ON pushbutton Function diagram Optionally cross fault detection in emergency-stop With fast auto start as option Width 45 mm Pushbutton On Approvals and marking Emergency- stop (Off) * * K2 Deutschland Canada / USA * see variants Applications * Short-circuit detection K3 at the On pushbutton Protection of persons and machines M 6742 - Emergency-stop circuits on machines - Monitoring of safety gates Block diagram Indication A1(+)A2(-) S11 S12 S22 S33 S34 13 23 33 41 upper LED: on when supply voltage connected lower LEDs: on when relay K2 and K3 active Notes overvoltage monitoring and short circuit logic K2 Line fault detection at the ON pushbutton: protection If the ON pushbutton was already closed before the voltage was applied at S12, S22 (also in the case of line fault via the ON pushbutton), the output contacts cannot be switched on. K2 K3 24V A line fault at the ON pushbutton which occured after activation of the unit K3 is recognized when switching on takes place again and switching-on of power K2 K3 the output contacts is prevented. If a line fault occurs at the ON pushbutton after the voltage has already been applied at S12 and S22, unwanted activation occures because this line fault can not be distinguished from the regular switching-on function. The PE testing terminal allows the units to be also operated in IT networks with insulation monitoring. It also M7023 a S21/PE(-) 14 24 34 42 serves as a reference point for checking the control voltage and as a connection contact in the event of an emergency-stop with cross fault detection. Circuit diagrams A1 A1 A1 S11 S12 S22 13 21 S11 S12 S22 13 23 33 41 T11 T12 T22 13 23 33 41 (+) (+) (+) A1 S22 13 21 A1 S22 13 23 33 41 A1 T22 13 23 33 41 S11 S11 T11 S12 K2 S12 K2 T12 K2 S33 S33 T33 S34 K3 S34 K3 T34 K3 A2 S21/PE 14 22 A2 S21/PE 14 24 34 42 A2 T21/PE 14 24 34 42 S21 A2 S21 A2 T21 A2 S33 S34 14 22 S33 S34 14 24 34 42 T33 T34 14 24 34 42 (-) (-) /PE /PE (-) /PE M7792 b M7372 b M7373 c BD 5935.48 BD 5935.48/200 BD 5935.16 All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. BD 5935 / 08.05.06 e 1 0221548Unit programming M7483 plate Notes Technical data Because of the gold-plated contacts the BD 5935 can be used to switch Operate time small loads 1 mVA ... 7 VA, 1 mW ... 7 W in the range of 0,1 ... 60 V, 1 ... activation via ON pushbutton:50 ms - 25 % + 50 % 300 mA. The gold-plated contacts allow also to switch the maximum automatic ON function: 1 s - 25 % + 50 %, as option also current but the gold plating will be burnt off. After that the contacts cannot with shorter on-delay (see variants) be used any more to switch the small loads. Release time opening in secondary circuit One or more extension modules BN 3081 or external contactors with (S12-S22): 25 ms - 25 % + 50 % opening in supply circuit: 50 ms - 25 % + 50 % positively driven contacts can be used to multiply the number of contacts of the emergency-stop module BD 5935. Contact type: relay, positively-driven The switches S1 and S2 are provided for the following selection Rated output voltage: AC 250 V DC: see arc limit curve possibilities: Automatic-start, manual-start and emergency-stop with or without cross fault detection. These switches are located behind the front Thermal current I : see quadratic total current limit curve th (max. 10 A in one contact path) cover panel (see unit programming diagrams). Switch S2 is for selecting automatic or manual Start. In addition, terminals Switching capacity S33 and S34 must be jumpered forautomatic start functio. to AC 15 for NO contact: AC 5 A / 250 V IEC/EN 60 947-5-1 Selection of the operating mode with or without cross fault detection at the emergency-stop pushbutton is performed via the switch S1. The unit for NC contact: AC 2 A / 250 V IEC/EN 60 947-5-1 Electrical life must be connected as shown in the application example. 5 to AC 15 at 2 A, AC 230 V: 10 switching cycles IEC/EN 60 947-5-1 ATTENTION - AUTOMATIC START Permissible operating frequency: 600 switching cycles / h According to IEC/EN 60 204-1 part 9.2.5.4.2 it is not Short circuit strength allowed to restart automatically after emergency stop. max. fuse rating: 6 A gL IEC/EN 60 947-5-1 Therefore the machine control has to disable the max. line circuit breaker: C 10 A automatic start after emergency stop. 6 Mechanical life: 10 x 10 switching cycles Technical data General data Input Operating mode: Continuous operation Nominal voltage U : AC 24, 48, 110, 127, 230, 240 V N Temperature range: - 15 ... + 55 C DC 24 V at max. 90% humidity Voltage range: AC 0,85 ... 1,1 U N Clearance and creepage at 10% residual ripple: DC 0,9 ... 1,2 U distances N at 48% residual ripple: DC 0,8 ... 1,1 U overvoltage category / N Nominal consumption: AC approx. 4 VA, DC approx. 2 W contamination level: 4 kV / 2 IEC 60 664-1 Nominal frequency: 50 / 60 Hz EMC Recovery time: 0,5 s after activating the emergency- Electrostatic discharge: 8 kV (air) IEC/EN 61 000-4-2 stop button. Fast transients: 2 kV IEC/EN 61 000-4-4 If the line fault detection of the ON- Surge voltages button is be active, the device must between stay off for approx. 5 sec. wires for power supply: 1 kV IEC/EN 61 000-4-5 Control voltage at S11: DC 24 V between wire and ground: 2 kV IEC/EN 61 000-4-5 Control current via S12, S22: approx. 35 mA 25 % at U Degree of protection: Housing: IP 40* IEC/EN 60 529 N Minimum voltage at Terminals: IP 20 IEC/EN 60 529 terminal S12, S22: DC 21 V when unit is activated * when front plate is removed to set switches, protection class IP 40 Output is not valid Housing: Thermoplastic with V0 behaviour Contacts according to UL subject 94 BD 5935.16: 1 NO / 1 NC contacts Vibration resistance: Amplitude 0,35 mm IEC/EN 60 068-2-6 BD 5935.48: 3 NO / 1 NC contacts frequency 10 ... 55 Hz The NO contacts are safety contacts. Climate resistance: 15 / 055 / 04 IEC/EN 60 068-1 ATTENTION The NC contacts 21-22 Terminal designation: EN 50 005 or 41-42 can only be used for monitoring. 2 M5960

Tariff Desc

8536.49.00 TC 17103979 RELAYS, PRINTED CIRCUIT BOARD

8536.41 TC 8909066 RELAYS, having a continuous contact rating of NOT less than 3A and body dimensions NOT exceeding 40mm x 30mm x 27mm

8536.49.00 TC 9613322 RELAYS, low profile, OTHER THAN reed relays, being EITHER of the following:
(a) height NOT exceeding 21.24 mm;
(b) height NOT exceeding 35 mm and having a continuous current rating NOT less than 8A AC

8536.49 TC 8906734 RELAYS, having ALL of the following:
(a) one, two or three contacts;
(b) maximum continuous contact current rating of NOT less than 15A;
(c) maximum contact voltage rating of NOT less than 380V;
(d) maximum switched power rating of NOT less than 4000VA

8536.49.00 TC 1122469 RELAYS, having an operating voltage NOT exceeding 250 volts, having ANY of the following:
(a) spring loaded terminals
(b) plug-in screw terminals
(c) wire connected terminals

8536.41 TC 8534635 RELAYS, cradle, having ALL of the following:
(a) maximum switching current NOT exceeding 5 A (AC or DC);
(b) switching voltage NOT exceeding 250 V (AC or DC);
(c) body dimensions NOT exceeding 31 mm x 36 mm x 19 mm

8536.49 TC 8633667 RELAYS, vacuum, hermetically sealed

8536.41.00 TC 19144923 RELAYS, SWITCH AMPLIFIER, having a supply voltage NOT greater than 40v

8536.49 8633669 RELAYS, thermal overload, having ALL of the following characteristics:
(a) trip time NOT exceeding 5 s at 6 times full load current
(b) manual reset
(c) maximum current 50A

8536.49 TC 8633636 RELAYS, power appliance, 15A, having EITHER 2 contacts or 3 contacts

8536.41 TC 8438513 RELAYS, mercury wetted, contact type

8536.41 TC 8438500 RELAYS, coaxial

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted