Additional Resources: Product Page 3D Model date 12/14/2020 page 1 of 6 SERIES: VGS-100D DESCRIPTION: INTERNAL AC-DC POWER SUPPLY FEATURES wide input range (85 ~ 305 VAC) available with conformal coating or terminal cover options active Power Factor Correction (PFC) certified to IEC/EN/UL 62368 designed to meet IEC/EN 61558, IEC/EN 60335, and GB4943 output over voltage, over current, over temperature, short circuit protection CISPR/EN55032 Class B radiated/conducted emissions input over voltage category III for fixed installations 3 output output output ripple efficiency MODEL 2 voltage current power and noise max max max typ range 1 (Vdc) (Vdc) (A) (W) (mVp-p) (%) VGS-100D-5 5 4.75 ~ 5.5 20.0 100.0 100 86 VGS-100D-12 12 11.4 ~ 13.8 8.5 102.0 100 85 VGS-100D-15 15 14.3 ~ 16.5 6.7 100.5 100 86 VGS-100D-24 24 22.8 ~ 27.6 4.2 100.8 150 86 VGS-100D-48 48 45.6 ~ 55.2 2.1 100.8 250 87 Notes: 1. Output adjustable via built-in trimpot. The actual adjustment range may extend beyond the values listed and care should be taken to ensure the output voltage and output power do not exceed stated limits. 2. Ripple & noise are measured at 20 MHz BW with 47 F aluminum electrolytic capacitor and 0.1 F ceramic capacitor on the output. 3. Measured at 230 Vac PART NUMBER KEY VGS-100D - XX - X Base Number A - with terminal cover Output Voltage B - with conformal coating cui.comAdditional Resources: Product Page 3D Model CUI Inc SERIES: VGS-100D DESCRIPTION: AC-DC POWER SUPPLY date 12/14/2020 page 2 of 6 INPUT parameter conditions/description min typ max units 85 264 Vac 5 Vdc output model 120 373 Vdc voltage 85 305 Vac all other output models 120 430 Vdc frequency 47 63 Hz at 85 Vac 1.7 A current at 115 Vac 1.3 A at 230 Vac 0.7 A at 115 Vac, cold start 25 A inrush current at 230 Vac, cold start 45 A leakage current at 240 Vac 2 mA at 115 Vac, full load 0.97 power factor at 230 Vac, full load 0.92 OUTPUT parameter conditions/description min typ max units 5 Vdc output 5,000 F 12 Vdc output 5,000 F capacitive load 15 Vdc output 5,000 F 24 Vdc output 4,200 F 48 Vdc output 2,200 F at full load initial set point accuracy 5, 12 & 15 Vdc output 2 % 24 & 48 Vdc output 1 % line regulation 0.5 % 0%~100% load load regulation 5 Vdc output model 1.0 % all other output models 0.5 % hold-up time at 230 Vac 16 ms temperature coefficient 0.05 %/C turn on (0 ~ 0.8 Vdc) remote on/off (CTRL) turn off (4 ~ 10 Vdc) PROTECTIONS parameter conditions/description min typ max units 5 Vdc output model, hiccup 7.5 Vdc 12 Vdc output model, hiccup 16.8 Vdc over voltage protection 15 Vdc output model, hiccup 20.25 Vdc 24 Vdc output model, hiccup 32.4 Vdc 48 Vdc output model, hiccup 60.0 Vdc over current protection constant current, auto-recovery 105 150 % over temperature protection activation 85 C over temperature protection1 over temperature protection deactivation 50 C short circuit protection constant current, continuous, auto-recovery Note: 1. Over temperature protection thresholds under full load conditions. cui.com