P/STD/PHC1 * * 00/B/27/12/1999 page 1 / 2 F/GB PHC1 00 CAPTEUR DE PROXIMITE MAGNETIQUE - un contact inverseur MAGNETIC PROXIMITY SENSOR - 1 contact changeover Dimensions / Outlines 1,4 2,54 17,78 23,12 0,5 CARACTERISTIQUES ELECTRIQUES / ELECTRICAL DATA Puissance maxi commutable / Max. switching power Contact repos / NC : 3 VA Contact travail / NO:8 VA Tension maxi commutable / Max. switching voltage 100 Vdc Courant maxi commutable / Max. switching current 250 mA Courant de travail / Carrying current 0,5 A Tension typique de tenue / Typical dielectric strength 200 Veff Rsistance de contact initiale ( max ) / Initial contact resistance < 150 m 9 Rsistance d isolement ( min ) / Insulation resistance 10 Capacit / Capacitance 2,5 pF Frquence maxi d utilisation / Max. frequency 150 Hz Frquence de rsonnance / Resonnant frequency 3000 Hz PPrroouudd ttoo sseerrvvee yyoouu PPrroouudd ttoo sseerrvvee yyoouu celduc All technical caracteristics are subject to change without previous notice. r e l a i s Caractristiques sujettes modifications sans pravis. 3,6 0,6 4,2 3,2P/STD/PHC1 * * 00/B/27/12/1999 page 2 / 2 F/GB Temps de commutation l action / Operate time contact travail / NO 1,5 ms au relchement / Release time contact repos / NC 2 ms CARACTERISTIQUES PHYSIQUES / PHYSICAL DATA Matriau utilis pour le contact / Contact material Rhodium Temprature maxi d utilisation / Max. operating temperature - 40 + 100C Temprature de stockage / Storage temperature - 55 + 100C ( temprature donne hors cable / given temperature, cable excepted ) Chocs ( 1/2 onde - 11 ms ) / Shocks ( 1/2 sine wave - 11 ms ) 30 g Vibrations ( de 30 2000 Hz ) / Vibrations 20 g 6 Dure de vie / Life expextancy 50 V = 100 mA > 1,5 . 10 6 ( charges rsistives / resistive loads ) 50 mV = 10 mA > 40 . 10 9 dure de vie mcanique / mecanical life expectancy 10 Indice de protection ( nettoyage par jet d eau usage industriel et ambiance poussireuse ) Protection level ( Cleaning with jet of water, industrial use, dusty environment ) IP67 AUTRES CARACTERISTIQUES / OTHERS Plage de sensibilit utilise / Used pull-in range de 15 35 ATf / from 15 up to 35 AT Pour d autres sensibilits , nous consulter / For others, please contact us Dwell 0 2 AT Diffrentielle : ATO( NF / NC ) Pull in value 0,5 D 0,65 ATF ( NO / NO) Drop out value Rfrences disponibles / Available references PHC11200 --> de 15 20 ATf PHC12300 --> de 20 25 ATf PHC14500 --> de 30 35 ATf PHC13700 --> de 20 35 ATf Dtection / Detection Commande par aimant / Ordered by magnet Type P6250000 ou / or P4200000 ou / or PA320000 Pour d autres types ou utilisations , nous consulter / For others, please contact us Distances mini d enclenchement / Min. closing distances ( 1,5 mm ) X2 avec aimant / with magnet : P6250000 ( indicatif / for guidance ) X1 X X1 = 24 mm X2 = 7 mm B = 19 mm B A Gris / grey : enclenchement / operating celduc www.celduc.com r e l a i s Rue Ampre B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tl. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tl. +33 (0) 4 77 53 90 19