Product Information

RSBS2325A2V12C24

RSBS2325A2V12C24 electronic component of Carlo Gavazzi

Datasheet
1PH SOFT START 230V 25A 240 CASE 6MM TERM

Manufacturer: Carlo Gavazzi
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 704.7773 ea
Line Total: USD 704.78

3 - Global Stock
Ships to you between
Fri. 03 May to Thu. 09 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
1 - Global Stock


Ships to you between Fri. 03 May to Thu. 09 May

MOQ : 1
Multiples : 1

Stock Image

RSBS2325A2V12C24
Carlo Gavazzi

1 : USD 701.925
3 : USD 671.6718
5 : USD 661.5918
10 : USD 651.6825

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
A82-2050 electronic component of Carlo Gavazzi A82-2050

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 2

A82-20500 electronic component of Carlo Gavazzi A82-20500

Current Transformers 1PH CURR TXFORM-4-20MA OUTPUT
Stock : 3

AD2000 electronic component of Carlo Gavazzi AD2000

Power Analysers WM5-96 BASE WITHOUT OPTICAL PORT
Stock : 1

AQ1038 electronic component of Carlo Gavazzi AQ1038

Power Analysers 3 DIGITAL INPUTS FOR WM3
Stock : 1

AD1040 electronic component of Carlo Gavazzi AD1040

Power Analysers WM4-96 BASE REV.0
Stock : 1

AO1032 electronic component of Carlo Gavazzi AO1032

Test Accessories - Other 2 x +/-5V DC OUTPUT MODULE
Stock : 1

5100532 electronic component of Carlo Gavazzi 5100532

Panel Meters and Controllers Panel Meter Modular
Stock : 1

ACR1252U electronic component of Carlo Gavazzi ACR1252U

USB NFC READER/WRITER, 3-PHASE RELAY; Accessory Type:USB NFC Reader / Writer; For Use With:Carlo Gavazzi DPD Series 3-Phase Monitoring Relays; Product Range:-; SVHC:No SVHC (27-Jun-2018)
Stock : 0

AL-125-120VAC electronic component of Carlo Gavazzi AL-125-120VAC

LATCH UNIT 100-25A
Stock : 1

APD140-TC01 electronic component of Carlo Gavazzi APD140-TC01

Sensor Fixings & Accessories TEST CABLE NO.1 FOR PD140
Stock : 1

Image Description
GV2AF4 electronic component of Schneider GV2AF4

Motor Drives MAN-START 600VAC 38A COMBO BLOCK
Stock : 1

Hot 1302263150 electronic component of Molex 1302263150

Motor Drives ASSY; BRUSH/SHUNT SR400
Stock : 1

LU9C1 electronic component of Schneider LU9C1

Motor Drives BLANKING COVER MODULE SLOT
Stock : 0

GV7AC03 electronic component of Schneider GV7AC03

Motor Drives MAN-START TERMINAL EXTENSION KIT IEC
Stock : 0

GV2G354 electronic component of Schneider GV2G354

Motor Drives MAN-START BUSBAR 600VAC 63AMP IEC
Stock : 5

1302263161 electronic component of Molex 1302263161

Motor Drives KIT; (3) BRUSHES REPLACEMENT
Stock : 0

AFA63CA/BC/T electronic component of Besel AFA63CA/BC/T

Motor: AC
Stock : 1

GV2LE07 electronic component of Schneider GV2LE07

Schneider Electric
Stock : 1

GV2LE22 electronic component of Schneider GV2LE22

Schneider Electric
Stock : 5

LU9BN11L electronic component of Schneider LU9BN11L

Motor Drives PRE-WIRED CONTROL MODULE - LUB/LUS
Stock : 0

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24.. Soft starting of 1-Phase Scroll Compressors Enclosed solution Integrated current limit Rated operational voltage: 230 VACrms, 50/60 Hz Rated operational current: up to 32A: AC-53b Integral bypassing of semiconductors Built-in transient overvoltage protection Undervoltage protection after ramp up DIN rail or panel mount EMC Compliant Optional auxiliary alarm relay output Relay Protection UL, cUL listed 4 Optimised algorithm for high pressure starts Integrated protection against short-cycling Voltage dips and interruptions detection Bi-colour LED for indication of delay between starts and/or alarm Product Description Ordering Code RSB S 23 32 A2 V12 C24 HP This motor controller, intended to be Short circuit and Overload protection Board level Motor Controller used with single-phase scroll compres- are not provided with this controller and Scroll Compressor sors can limit inrush currents to must be procured separately. Starting Rated operational voltage 40AACrms for RSBS2325A2V.2C24.. and running capacitors are required for Rated operational current and 45AACrms for controller to operate as intended. Control voltage 1 RSBS2332A2V.2C24. Upon applying Options the control signal, soft starting is The RSBS can also be supplied with an Starting Capacitor 2 achieved within a 600ms interval . At optional auxiliary alarm relay (Option - Version the end of the soft-start function, the V22). semiconductors are bypassed by elec- tromechanical relays. The device rating Note: The main and bypass relays The RSBS can detect voltage dips and interruptions 50msec is based on a maximum of 12 starts per may be in an undefined state due to (+20msec/-0msec)* 3 hr. transportation. In case both relays are latched in the ON state, there will * for 50Hz supply Application of supply voltage is indicat- be a direct on line start of the com- ed by a green LED in the full ON state. pressor - even without control signal. Alarm indication is provided through a To avoid the direct on line start, the red LED which signals the type of alarm user may do a first power up with no via a user friendly flashing sequence. load connected for a period of 3seconds. Delay between starts and/or from stop to start is indicated via an orange LED. Type Selection Type Rated operational Rated operational Control Options Starting Capacitor Version voltage Ue Current Ie Voltage Uc RSBS: 1-Phase 23: 230VACrms 25: 25AAC A2: 230VACrms V12: Enclosed C24:200-240F HP:High SoftStarterfor 32: 32AAC V22: Enclosed PressureStarts ScrollCompressors &aux.alarmrelay Selection Guide Rated operational voltage Ue Rated operational current Ie Option 25A AC-53b 32A AC-53b 230V ACrms 50/60Hz RSBS2325A2V12C24 RSBS2332A2V12C24 Enclosed RSBS2325A2V22C24 RSBS2332A2V22C24 Enclosed and RSBS2332A2V12C24HP Aux. alarm relay RSBS2332A2V22C24HP Notes: 1. Applicable to balanced pressure starts in case of RSBS2332A2V.2C24HP 2. For RSBS2332A2V.2C24HP, ramp time is < 1 sec. 3. For RSBS2332A2V.2C24HP, max. starts per hour = 10 4. Applicable to RSBS2332A2V.2C24HP ATTENTION: The RSBS soft starter is NOT to be used as a safety device. The RSBS, on its own, cannot guarantee any safety and therefore other components need to be used to ensure that the system operates safely. Note: Power up is defined as the moment when L/L1 and N/L2 are applied to the RSBS. Specifications are subject to change without notice (12.12.2013) 1RSBS23..A2V.2C24.. General Specifications Housing Specifications Dimensions (L x B x H)* 137 x 81.4 x 60.4 mm Ramp up (preset) RSBS23..A2V.2C24 < 0.6 sec Weight approx 450g RSBS2332A2V.2C24HP < 1 sec Material Polyamide Operating temperature -20 to +65C (-4 to +149F) Terminal tightening screws Screw Type Storage temperature -30 to +70C (-22 to +158F) (Max. tightening torque) Degree of protection IP20 R, Rc, L, N, ON, S M4 (1.19Nm, 10.5lb-in) Pollution Degree 2 14, 12, 11 M3 (0.5Nm, 4.5lb-in) Overvoltage category II Max. cross sectional area of cable (solid) Relative humidity < 95% non condensing 40C 2 R, Rc, L, N, ON, S 0.5 - 16mm , AWG 20-6 Altitude* 1000m 2 14, 12, 11 0.2 - 1.5mm , AWG 28-12 Max. cross sectional area of cable (stranded) 2 R, Rc, L, N, ON, S 0.5 - 16mm , AWG 20-6 2 14, 12, 11 0.2 - 1.5mm , AWG 30-12 Stripping length R, Rc, L, N, ON, S 8mm 14, 12, 11 7 - 8mm * Above 1000m derate linearly by 1% of unit FLC per 100m to a maximum * For RSBS23....V22...., the auxiliary terminal is 10.5mm protruding altitude of 2000m Output Specifications RSBS..25A.V.2C24 RSBS..32A.V.2C24.. RSBS2332A2V.2C24HP Rated operational current 25A AC-53b 32A AC-53b 32A AC-53b Compressor rating/ UL rating 4.4kW/ 5HP 4.4kW/ 5HP 4.4kW/ 5HP 1 Max. starting current 40A ACrms 45A ACrms 80A ACrms Overload profile 25A: AC-53b: 1.6 - 1:60 32A: AC-53b: 1.4 - 1:60 32A: AC-53b: 1.4 - 1:60 No. of starts/hr 12 (evenly distributed) 12 (evenly distributed) 10 (evenly distributed) 2 2 2 I2t for fusing t=10ms 1200 A s 1200 A s 1200 A s Minimum full load current 2.5AACrms 2.5AACrms 2.5AACrms Minimum time between starts 5 min 5 min 6 min Minimum time between stop to start 1 min 1 min 3 min Input Specifications (Control Input) Supply Specifications RSBS23..A2V.2C24.. RSBS23..A2V.2C24.. Control voltage (Uc), ON 230VACrms 15% Rated operational voltage (Ue) Input Current 3 ... 6mA L - N 230 VAC 15% Pick up voltage 90 VAC Rated AC frequency 50/60Hz 5Hz Drop out voltage 25 VAC Rated insulation voltage 250 VACrms Rated AC frequency 50/60 Hz 5Hz Supply indication Green LED Rated insulation voltage 250 VAC rms Undervoltage alarm* < 190 VACrms for 1 sec Response time Overcurrent alarm > 80 Arms for 1 sec Input to output <200ms Alarm indication Red LED/Aux Relay Output** ** Current at no load 15 mA Auxiliary Alarm Relay Pickup voltage (internal power supply) 90VAC Alarm Common, Normally Open, Normally Closed, Changeover Drop Out voltage (internal power supply) 25VAC Contact Rating 3A, 250VAC * Not available during ramping. Refer to voltage dips and interruptions sec- 3A,30VDC tion for mode of operation. ** Only for RSBS23..A2V22C.. Note: 1. A maximum of 80 Arms current limit may result in case of a locked rotor/ high pressure starting condition. 2 Specifications are subject to change without notice (12.12.2013)

Tariff Desc

8501.10.00 1235865 MOTORS FAN DC having a power output NOT greater than 37.5W
8501.10.00 9613254 MOTORS DC electronic commutation, brushless
8809089 8501.10.00 TC 838091 DRIVES, SERVO, rated output voltage NOT greater than 34VDC
8809089 8501.4 TC 8809089 MOTORS stepping being motors that convert electrical digital information into mechanical movement
8501.1 TC 8343006 MOTORS DC 6V, 12V, 24V or 24V to 28V, having an output NOT exceeding 6.5W
8501.10.00 TC 9700723 MOTORS DC having ALL of the following:
(a) rated voltage NOT exceeding 24VDC
(b) external housing diameter NOT exceeding 40.5mm
(c) external housing length NOT exceeding 78.5mm
For the purposes of the order ALL measurements have a tolerance of plus OR minus 5%
Does NOT include replacement components in passenger motor vehicles
8501.1 TC 8343160 MOTORS DC 1.5V or greater but NOT exceeding 12V speed 4700 r/min or greater but NOT exceeding 20000r/min, but NOT including such motors imported with, or incorporating, a gearbox, maximum exterior frame dimensions 47mmx60mm
8501.10.00 TC 9701153 MOTORS DC having ALL of the following
(a) rated voltage NOT exceeding 15VDC
(b) external housing diameter NOT exceeding 50mm
(c) external housing length NOT exceeding 75mm
(d) performance NOT exceeding 840gr/cm torque at maximum efficiency
8501.10.00 9802584 MOTORS, DC, having ALL of the following
(a) external motor housing diameter NOT exceeding 47mm
(b) external motor housing length NOT exceeding 69mm
(c) fitted with EITHER one OR both of the following
(i) reduction gearhead having an external housing diameter NOT exceeding 42mm and an external housing length NOT exceeding 55mm
(ii) digital or optical encoder
Carlo Gavazzi Computing Solutions

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted