DuplineSafe Safety Input Module Type GS 7510 2101-1 Bus-powered input module Single input for potential-free contacts Small dimension IP67 housing for de-central installation at the actual location of the switch Safety approved according to IEC/EN 61508-SIL3, IEC/EN 62061-SIL3 and ISO/EN 13849-1 PL e Approval authority: TV Rheinland Group Uses two Dupline channels Operates on a standard Dupline network It is possible to use DuplineSafe modules and standard Dupline modules on the same bus Address coding with GS73800080 Typically used for emergency stops or other NC safety contacts Product Description Ordering Key GS 7510 2101-1 Bus-powered safety input inside a pull-cord switch. DuplineSafe module approved according The module is always used Housing to IEC/EN 61508-SIL3, in conjunction with the Buspowered input module IEC/EN 62061-SIL3 and DuplineSafe Safety Relay GS ISO/EN 13849-1 PL e by 38300143230. The safe TV. The module has a sin- state signal is transmitted Type Selection gle input for potential-free continuously to the Safety contacts, and it uses two Relay as long as the input Supply Ordering no. Dupline channels for send- contacts are closed and the DuplineSafe Safety Input Module ing the safety signal. The module self-check is OK. small dimension IP67 hous- The Dupline module is By Dupline GS 7510 2101-1 ing makes it suitable for de- delivered with a 8 pin male central installation, e.g. multi connector. Safety Specifications Supply Specifications Standards IEC/EN 61508-SIL3 Power Supply Supplied by Dupline IEC/EN 62061-SIL3 Reverse polarity protection Yes ISO/EN13849-1 PL e Current consumption Typ. 1,0 mA Approval authority TV Rheinland Group SFF 96% -6 PFD (T1 = 1 year) 5.0 x 10 -9 PFH 5.9 x 10 /h General Specifications Power ON delay < 5s Input Specifications Environment Degree of protection IP 67 Inputs 1 NC Contact Pollution degree 3 (IEC 60664) Open loop voltage 2.5 V Operating temperature -40C to 70C Short-circuit current 100 A Storage temperature -40C to 70C Contact resistance < 1k Cable length max. 2.5 m Humidity (non-condensing) 20 - 80% Dielectric voltage Mechanical resistance Inputs Dupline None Shock 15 G (11 ms) Vibration 2 G (6 to 55 Hz) Response time 1 Housing From input contact opens Material Valox PBT, Yellow to safety relay releases max 300 ms Dimensions 57,5 x 36,0 x 16,4 mm Response time 2 From input contact closes Termination Cable to safety relay activates max 600 ms Material PVC, Black Length 90 mm Dimension 6 x 0.5 mm2 Connector 8 pin multi connector Type MSTB 2.5/8-st-5.08 Phoenix number 1757077 Specifications are subject to change without notice (02.04.2013) 1 Dupline is a registered trademark. A product of the CARLO GAVAZZI GroupGS 7510 2101-1 Mode of Operation The DuplineSafe Safety GS75102101-1s fails to Please refer to the user Safety Transmit channel 1 Input module GS75102101-1 send the safe state signal manual for the DuplineSafe and Safety transmit channel is used to monitor the status the Safety Relay will release. Configuration Unit 2 are used by the of one potential-free contact GS73800080 for detailed GS75102101-1 to transmit in a safety device, e.g. an instructions on how to the status of the safety Addressing emergency stop palm button configure the Safety switch in a dynamic way, For addressing of or pull cord switch. The sta- Transmitter GS75102101-1 ensuring redundancy, diver- GS75102101-1, the Dupline- tus of the safety contact is with the desired addresses. sity and continuous updat- Safe Configuration Unit continuously transmitted on ing. Each GS75102101-1 GS73800080 is used. The the Dupline bus using a must be coded for a unique The synchronization channel GS75102101-1 must have 3 dynamic signaling principle channel pair not used by any is used by the Safety Relay Dupline channels assigned on two Dupline channels. other GS75102101-1. to send out a synchroniza- to it The Safety Input module is Please refer to the datasheet tion signal to the Safety always used in conjunction Synchronization channel for the safety relay Input modules on the bus. with the DuplineSafe Safety (same for all safety GS38300143230 for detailed Therefore, all the Safety Relay GS38300143230, transmitters) instructions how to ensure Input modules and the Safe- which can monitor up to 63 correct addressing, installa- Safety Transmit channel 1 ty Relay must be coded for Safety Input modules all tion and configuration of a the same synchronization Safety Transmit channel 2 connected to the same DuplineSafe safety system. channel. Dupline bus. If one or more Installation Rules Due to fact that the Dupline- stop button must be exclud- 13849-2 table D.6 (see These 3 conditions are usu- Safe input module is a single ed. This is possible, when below) are met. ally fulfilled, if the input mod- channel device (one input), the conditions, which are ule is placed very close to there are specific installation mentioned in EN ISO 13849- the E-Stop push-button and - The E-Stop button must rules that have to be 2 table D.4 (see below), are in a closed housing, which meet the requirements for followed in order to achieve met. meets IP 54 rating or higher. direct opening according to an installation complying The push-button and the EN 60947-5-1 Annex K. In with IEC/EN 61508-SIL3, cabling must not be - Short circuits between the this case it is ensured, that IEC/EN 62061-SIL3 and stressed by external adjacent terminals at the the contact in the E-Stop ISO/EN 13849-1 PL e : mechanical influences. The input of the input module button opens, when the E-Stop push-button must and between the terminals at push-button is pressed (see have been approved accord- - A short circuit between the E-Stop push-button table D.8 in EN ISO 13849-2 ing to EN 60947-5-1 for the 2 wires in the cable must be excluded. This is below). direct opening. between the terminals of the possible, when the condi- input modules and the E- tions mentioned in EN ISO Table D.4 Conductors/cables Fault considered Fault exlusion Remarks Short-circuit between any two Short-circuit between conductors wich are 1) Provided both the conductors conductors and enclosed meet the appropri- - Permanently connected (fixed) and protected ate requirements (see EN 60204-1 against external damage, e.g. by cable ducting, (IEC 60204-1)) armouring, or - seperate multicore cables, or - within an electrical enclosure (se remark 1)), or - individually shielded with earth connection. Short-circuit of any conductor to Short-circuits between conductors which are within - an exposed conductive part or to an electrical enclosure (see remark 1). earth or to the protective bonding conductor. Open-circuit of any conductor None - 2 Specifications are subject to change without notice (02.04.2013) Dupline is a registered trademark. A product of the CARLO GAVAZZI Group