CX-SCX-Series eries
CIRCUIT BREAKER
The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the
breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a
patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating
the arc into an enhanced arc chamber improving the breakers overall performance and reliability. The permanent
magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase
the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An
enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat
transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced
splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction
Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance
even in the most demanding applications.
Resources:
Configure a Complete Part
Download CAD & Sales Drawing
Watch Product Video
Product Highlights: High DC Voltage Applications:
UL 489 & UL 489B Listed Datacom, PDU and UPS Systems
TUV Certified IEC/EN 60947-2 Power Supplies and Convertors
Temperature stable hydraulic-magnetic Mission Critical Equipment
overcurrent sensing technology
Renewable Energy Systems
Optional relay trip circuit permitting remote
Motor Controllers
operator system shut down
Charging Stations
Perfect fit for 380VDC Applications
Smart Grids
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: sales@carlingtech.com www.carlingtech.com
Application Support: team2@carlingtech.com
Phone: 860.793.9281 Fax: 860.793.9231|
2 CX-Series Circuit Breaker Design Features
CX-Series
DESIGN FEATURES
HYDRAULIC/MAGNETIC UPPER ARC RUNNER MAGNETS ARC SPLITTER
SENSING COIL Aids in motivating arc off of movable RETAINER
contact and into arc chamber with integrated
pressurizing walls
PATENT PENDING MAGNETIC FLUX LOWER ARC RUNNER LARGE ARC GAP (12) ARC DEIONIZING
BOOSTING TERMINAL CONFIGURATION Aids in motivating arc To generate high SPLITTER PLATES
Design enhances motivation off of stationary contact arc voltages
of arc into arc chamber and into arc chamber
Email: sales@carlingtech.com Application Support: team2@carlingtech.com