Product Information

NTC15HP

Product Image X-ON

Datasheet
PROBE, NTC, PLASTIC, IP65
Manufacturer: Carel



Price (Ex GST)

From 29.1312

0 - Global Stock
MOQ: 1 Multiples:1
Pack Size :   1
Availability Price Quantity
0 - Global Stock


Ships to you between Tue. 25 Jan to Mon. 31 Jan

MOQ : 1
Multiples : 1

Stock Image

NTC15HP
Carel

1 : $ 20.2256
5 : $ 18.8244
10 : $ 18.4212
20 : $ 18.0558
50 : $ 17.6778

     
Manufacturer
Carel
Product Category
Unclassified
Brand
Carel
Length
15Mm
External Diameter
6Mm
Probe/Pocket Body Material
Plastic
Svhc
No SVHC (15-Jan-2019)
For Use With
Carel Temperature Sensors
Show Stocked Products With Similar Attributes. LoadingGif
Image Description
Stock Image IR33Z7LR20
CONTROLLER TEMP 4 RELAY OP
Stock : 0
Stock Image IR33W9MR20
CONTROLLER, TEMPERATURE, 2 RELAY, UNIV
Stock : 0
Stock Image IR33V9MR20
CONTROLLER, TEMPERATURE, 1 RELAY, UNIV
Stock : 0
Stock Image IR33Z9MR20
CONTROLLER, TEMPERATURE, 4 RELAY, UNIV
Stock : 0
Stock Image IR33W7LR20
CONTROLLER TEMP 2 RELAY OP
Stock : 0
Stock Image IR33V7LR20
CONTROLLER TEMP 1 RELAY OP
Stock : 0
Stock Image PJEZSNP000
CONTROLLER TEMP 1 RELAY OP
Stock : 0
Stock Image TRA12UN100
TRANSFORMER, 240VAC IN, 12VAC OUT, 3VA
Stock : 25
Stock Image PTC0150000
PTC PROBE, IP65
Stock : 0
Image Description
Stock Image LTC6993MPS6-3#TRMPBF
Monostable Multi-vibrator ONE SHOT with Falling Edge Trigger, Non-Retriggerable
Stock : 0
Stock Image 33-630
KIT, COMPRESSION, SERVICE
Stock : 0
Stock Image D55342M07B200JRS6
Res Thick Film 1206 200 Ohm 5% 1/4W ±300ppm/°C 0.01% Molded SMD SMD T/R
Stock : 0
Stock Image DCMY8W8SNMBK52
DSUB 8W8 F SOD NMB FLOA G50
Stock : 0
Stock Image DCMY8W8SNMBK47
D-Sub Standard Connectors
Stock : 0
Stock Image D55342M07B200DRWB
Military SMT Thin Film Resistor 1206 200 ? 250 mW 300 ppm/C
Stock : 0

ENG 1. INTRODUCTION 1.1 General description The Carel passive temperature probes are devices that, when connected to the controller, provide a resistance value, which is then converted to a temperature by the electronic controller. These are used in HVAC/R applications, and represent a complete range capable of satisfying a variety of needs in di? erent installations. The probes are made using materials that guarantee constant quality. The range includes various models that di? er based on the performance of the system and the ? elds of application. The probes have di? erent types of sensor (NTC, PTC, Pt1000), caps, index of protection, cable length, operating ranges and mechanical dimensions. In addition, models are available for use in hydronic systems, applied directly onto the tubing, which simplify installation and o? er a faster response in the reading, improving the wiring of the HVAC/R unit and improving performance. The probes are used together with Carel electronic controllers (parametric and programmable). 2. NTC TECHNICAL SPECIFICATIONS 2.1 Models NTC*HP* Storage conditions -20T70 ?C Operating range -50T105 ?C in air -50T50 ?C in ? uid Connections Stripped ends, dimensions: 5?1 mm Sensor NTC 10 k? ?1% at 25 ?C Beta 3435 Dissipation factor (in air) approx. 3 mW/?C Thermal constant over time (in air) approx. 75 s 2 Cable Black two-wire ? at cable, with tinned copper wire size 0.3 mm Sensitive element index of protection IP67 Sensitive element housing Polyole? n Classi? cation according to protection against electric Basic insulation for 250 Vac shock (sensitive element & cable) Category of resistance to heat and ? re Flame retardant Standard NSF 15 L = * * = see table of product codes in price list Warning: all measures present in this manual are in millimeters. Passive probe man. +030220655 - rel. 1.6 - 02.12.2011 7 6x5ENG 1. INTRODUCTION 1.1 General description The Carel passive temperature probes are devices that, when connected to the controller, provide a resistance value, which is then converted to a temperature by the electronic controller. These are used in HVAC/R applications, and represent a complete range capable of satisfying a variety of needs in di? erent installations. The probes are made using materials that guarantee constant quality. The range includes various models that di? er based on the performance of the system and the ? elds of application. The probes have di? erent types of sensor (NTC, PTC, Pt1000), caps, index of protection, cable length, operating ranges and mechanical dimensions. In addition, models are available for use in hydronic systems, applied directly onto the tubing, which simplify installation and o? er a faster response in the reading, improving the wiring of the HVAC/R unit and improving performance. The probes are used together with Carel electronic controllers (parametric and programmable). 2. NTC TECHNICAL SPECIFICATIONS 2.1 Models NTC*HP* Storage conditions -20T70 ?C Operating range -50T105 ?C in air -50T50 ?C in ? uid Connections Stripped ends, dimensions: 5?1 mm Sensor NTC 10 kO ?1% at 25 ?C Beta 3435 Dissipation factor (in air) approx. 3 mW/?C Thermal constant over time (in air) approx. 75 s 2 Cable Black two-wire ? at cable, with tinned copper wire size 0.3 mm Sensitive element index of protection IP67 Sensitive element housing Polyole? n Classi? cation according to protection against electric Basic insulation for 250 Vac shock (sensitive element & cable) Category of resistance to heat and ? re Flame retardant Standard NSF 15 L = * * = see table of product codes in price list Warning: all measures present in this manual are in millimeters. Passive probe man. +030220655 - rel. 1.6 - 02.12.2011 7 6x5X-ON Electronics Authorized Distributor Click to view similar products for Carel manufacturer. Other Similar products are found below : IR33V7LR20 IR33V9MR20 IR33W7LR20 IR33Z7LR20 IR33Z9MR20 NTC015WH01 NTC15HP PTC0150000 TRA12UN100 ENG 1. INTRODUCTION 1.1 General description The Carel passive temperature probes are devices that, when connected to the controller, provide a resistance value, which is then converted to a temperature by the electronic controller. These are used in HVAC/R applications, and represent a complete range capable of satisfying a variety of needs in di? erent installations. The probes are made using materials that guarantee constant quality. The range includes various models that di? er based on the performance of the system and the ? elds of application. The probes have di? erent types of sensor (NTC, PTC, Pt1000), caps, index of protection, cable length, operating ranges and mechanical dimensions. In addition, models are available for use in hydronic systems, applied directly onto the tubing, which simplify installation and o? er a faster response in the reading, improving the wiring of the HVAC/R unit and improving performance. The probes are used together with Carel electronic controllers (parametric and programmable). 2. NTC TECHNICAL SPECIFICATIONS 2.1 Models NTC*HP* Storage conditions -20T70 ?C Operating range -50T105 ?C in air -50T50 ?C in ? uid Connections Stripped ends, dimensions: 5?1 mm Sensor NTC 10 kO ?1% at 25 ?C Beta 3435 Dissipation factor (in air) approx. 3 mW/?C Thermal constant over time (in air) approx. 75 s 2 Cable Black two-wire ? at cable, with tinned copper wire size 0.3 mm Sensitive element index of protection IP67 Sensitive element housing Polyole? n Classi? cation according to protection against electric Basic insulation for 250 Vac shock (sensitive element & cable) Category of resistance to heat and ? re Flame retardant Standard NSF 15 L = * * = see table of product codes in price list Warning: all measures present in this manual are in millimeters. Passive probe man. +030220655 - rel. 1.6 - 02.12.2011 7 6x5ENG 1. INTRODUCTION 1.1 General description The Carel passive temperature probes are devices that, when connected to the controller, provide a resistance value, which is then converted to a temperature by the electronic controller. These are used in HVAC/R applications, and represent a complete range capable of satisfying a variety of needs in di? erent installations. The probes are made using materials that guarantee constant quality. The range includes various models that di? er based on the performance of the system and the ? elds of application. The probes have di? erent types of sensor (NTC, PTC, Pt1000), caps, index of protection, cable length, operating ranges and mechanical dimensions. In addition, models are available for use in hydronic systems, applied directly onto the tubing, which simplify installation and o? er a faster response in the reading, improving the wiring of the HVAC/R unit and improving performance. The probes are used together with Carel electronic controllers (parametric and programmable). 2. NTC TECHNICAL SPECIFICATIONS 2.1 Models NTC*HP* Storage conditions -20T70 ?C Operating range -50T105 ?C in air -50T50 ?C in ? uid Connections Stripped ends, dimensions: 5?1 mm Sensor NTC 10 kO ?1% at 25 ?C Beta 3435 Dissipation factor (in air) approx. 3 mW/?C Thermal constant over time (in air) approx. 75 s 2 Cable Black two-wire ? at cable, with tinned copper wire size 0.3 mm Sensitive element index of protection IP67 Sensitive element housing Polyole? n Classi? cation according to protection against electric Basic insulation for 250 Vac shock (sensitive element & cable) Category of resistance to heat and ? re Flame retardant Standard NSF 15 L = * * = see table of product codes in price list Warning: all measures present in this manual are in millimeters. Passive probe man. +030220655 - rel. 1.6 - 02.12.2011 7 6x5X-ON Electronics Authorized Distributor Click to view similar products for Carel manufacturer. Other Similar products are found below : IR33V7LR20 IR33V9MR20 IR33W7LR20 IR33Z7LR20 IR33Z9MR20 NTC015WH01 NTC15HP PTC0150000 TRA12UN100

Tariff Concession Code
Tariff Desc

Examine

Carel may also be referenced as

Carel