Product Information

ETM1411-2307

ETM1411-2307 electronic component of Cal Controls

Datasheet
DIGITAL TIMER, 1 X RELAY, 230VAC

Manufacturer: Cal Controls
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 96.8843 ea
Line Total: USD 96.88

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 17 May to Thu. 23 May

MOQ : 1
Multiples : 1

Stock Image

ETM1411-2307
Cal Controls

1 : USD 149.7782

     
Manufacturer
Product Category
Brand
Supply Voltage Min
Supply Voltage Max
Time Min
Time Max
Panel Cutout Height
Panel Cutout Width
Digit Height
External Depth
External Length / Height
External Width
Input Voltage Max
Led Colour
Operating Temperature Max
Operating Temperature Min
Operating Temperature Range
Operating Time Range
Output Relay
Panel Cutout Depth
Power Consumption
Supply Voltage Ac Max
Supply Voltage Range
Supply Voltage V Ac
Time Range
Weight
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
991.12C electronic component of Cal Controls 991.12C

TEMPERATURE CONTROLLER, 230VAC
Stock : 0

991.11C electronic component of Cal Controls 991.11C

TEMPERATURE CONTROLLER, 115VAC
Stock : 0

95001PA001 electronic component of Cal Controls 95001PA001

TEMPERATURE CONTROLLER, LOGIC
Stock : 0

E-NTC-APP-1.5P7 electronic component of Cal Controls E-NTC-APP-1.5P7

PROBE, NTC, PLASTIC SHELL, PVC CABLE
Stock : 0

E-NTC-APT-1.5T7 electronic component of Cal Controls E-NTC-APT-1.5T7

PROBE, NTC, THERMOPLASTIC SHELL&CABLE
Stock : 0

992.11C electronic component of Cal Controls 992.11C

TEMPERATURE CONTROLLER, 115VAC
Stock : 0

320050 electronic component of Cal Controls 320050

TEMPERATURE CONTROLLER, 24VAC
Stock : 0

3C0000407 electronic component of Cal Controls 3C0000407

COMMUNICATION BOARD, RS485
Stock : 0

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

www.cal-controls.com ETM1411-230VAC DIGITAL TIMER SN: XXXXXXXXX START 1 2 3 4 5 6 7 8 9 10 11 12 OUT 250V AC 8A RESISTIVE LOAD 230V AC +10% -20% 50/60Hz 3VA TECHNICAL SPECIFICATIONS ENVIRONMENTAL CONDITIONS Ambient/storage temperature 0 ... +50C/-25 ... +70C (with no icing) 80% up to 31C decreasing linearly 50% at 40C. Max. Relative humidity Rated pollution degree According to EN 60529 Front panel : IP60 Rear panel : Ip20 CAL ETM1411 DIGITAL TIMER Height Max. 2000m Do not use the device in locations subject to corrosive and flammable gases. Thank you for choosing the CAL ETM1411 digital timer. ELECTRICAL CHARACTERISTICS * 34 x 77mm sized. Supply 230V AC +%10 -%20, 50/60Hz or 24V AC/DC%10, 50/60Hz or 12V AC/DC %10, 50/60Hz. * Single contact output for timing control. Power consumption Max 3VA ETM1411 START * External start input. OUT HOUR MIN Wiring 2.5mm screw-terminal connections * Display can be adjusted to show min. or sec. Scale Selectable 99:59 min. or hour. * Scale SET Sensitivity 1 sec. 0:01 .... 99:59 min. Time Accuracy %1 0:01 .... 99:59 hour Indicator 4 digits, 12mm, 7 parts yellow LED * Decrease and increace step of time can be adjusted. EMC EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests. STOP CAL DIGITAL TIMER * Start and stop possibility by front panel. The device is designed to operate in controlled electromagnetic environment) * 16 different warning tones. Safety requirements EN 61010-1: 2001 (pollution degree 2, overvoltage category II) * Upper and lower limits of the setpoint can be adjusted. * CE marked according to European Norms. OUTPUT OUT Relay: 250V AC, 8A (for resistive load), NO+NC Mechanical 30.000.000 operation Electrical 100.000 operation Life expectancy for relay Output Supply Voltage Order Code 230V AC +%10 -%20 ETM1411-230VAC START INPUT Relay 12V AC/DC %10 ETM1411-12 Input type Control with mechanical contact. 24V AC/DC %10 On and Off times for input pulses Min. = 100ms, Max. = ETM1411-24 Connection Diagram HOUSING Housing type Suitable for panel mounting CAL ETM1411 is intended for installation in control panels. Make sure that the device is Dimensions W77xH34xD70mm used only for intended purpose. The shielding must be grounded on the instrument side. Weight Approx. 240g (after packing) During an installation, all of the cables that are connected to the device must be free of Self extinguishing plastics Enclosure material electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded. All input and While cleaning the device, solvents (thinner, benzine, acid etc.) or corrosive materials must not be used. output lines that are not connected to the supply network must be laid out as shielded and twisted cables. These cables should not be close to the power cables or components. The installation and electrical connections must be carried out by qualified staff and must be Dimensions Depth according to the relevant locally applicable regulations. 85mm 8mm 70mm For removing mounting clamps: www.cal-controls.com www.cal-controls.com ETM1411 START OUT HOUR MIN Push out the mounting clamp ETM1411-12 ETM1411-230VAC in direction 1 as shown SET DIGITAL TIMER Equipment is protected throughout DIGITAL TIMER in the figure below. Then, pull SN: XXXXXXXXX by DOUBLE INSULATION. SN: XXXXXXXXX out the clamp in direction 2. DIGITAL TIMER STOP CAL Holding screw 2 0.4-0.5Nm mounting mounting Panel Rubber clamp clamp gasket START START 1 Panel cut-out Note:1) Panel thickness 71mm should be maximum 123456 789 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 7 mm. 2) If there is no 60mm free space at the back side of the device, it Note: NOTE : Fuse would be difficult to SUPPLY: F 100 mA 1) Mains supply cords shall meet the requirements of remove it from the panel. Switch 250V AC IEC 60227 or IEC 60245. 7 Line 184-253V AC 2) In accordance with the safety regulations, the power 230V AC 50/60Hz 3VA 8 Neutral supply switch shall bring the identification of Supply the relevant instrument and it should be easily accessible Fuse should CAL CONTROLS LTD Cable size: 1,5mm by the operator. be connected. Bury Mead Road, Hitchin, Herts, SG5 1RT, UK. Tel : +44 (0) 1462 436161 Fax : +44 (0) 1462 451801 e-mail: sales cal-controls.co.uk Web : www.cal-controls.com 1/2 ETM1411-E-03 Please read this document carefully before using this product. The guarantee will be invalidated if the device is damaged by not following instructions detailed in the manual. CAL Controls shall not be responsible for any damage or losses however caused, which may be experienced as a result of the installation or use of this product. OUT 250V AC 8A RESISTIVE LOAD 230V AC +10% -20% 50/60Hz 3VA OUT 250V AC 8A RESISTIVE LOAD 12V AC/DC 10% 50/60Hz 3VA 34mm 29mm: : : : INDICATOR OF INDICATOR OF SELECTING SELECTING INDICATOR OF MINUTE HOUR Displayed time value in the run mode, parameter value or name in the programming mode. CONTACT OUTPUT When held down for one second in the run mode, timer runs. Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the ETM1411 START OUT run mode. When held down for a few seconds, the change rate accelerates. HOUR MIN SET When held down for one second in the run mode, timer and voiced warning are stopped.(WhenStr.t. =TYP.1 mode is selected, timer and voiced warning can be stopped if external start input is off). Used for selecting parameters and decreasing the setpoint value in the programming mode and for decreasing the setpoint value in the run mode. When held down for a few seconds, the change rate accelerates. DIGITAL TIMER STOP CAL SET Used for adjusting the value of the setpoint in the run mode and for adjusting the selected parameter in the programming mode. For adjusting the selected parameter, while holding key, the value can be adjusted by using and keys. CONTROL DIAGRAM BY EXTERNAL START INPUT Run Mode Out.t. TYP.0 TYP.1 SET SET Time 3059 6000 5959 1000 value 6000 Str.t. Power SET When pressed key, TIMER set value flashes and by using and keys the value can be adjusted Out with the step defined byIn.de. Start TYP.0TYP.0 input Stop key SET SET If key is pressed and held for 3 seconds, If key is pressed, Indicator programming mode is entered. run mode is entered. Programming Mode Power T.S. T.c. Out SE TYP.1 Start input Selection of time unit. The lower limit Access code for entering Indicator Ifmin is selected, time can be of the setpoint. security menu. T.bas S.Cod. T.lol Adjustable between adjutable max. 99:59 min. This parameter should be 411. IfHour is selected, time can be 0.01 andT.uPl. CONTROL DIAGRAM BY START & STOP KEYS adjutable max. 99:59 h. Selection of start type. The upper limit Access code for timer set menu Out.t. TYP.0 TYP.1 By external start input and of the setpoint. NonE= Menu is invisible. T.uPl start/stop keys, timer can be run Str.t. A.-t.S. Adjustable between and stopped. 4 different selection P.yes= Parameters of menu Str.t. T.lol and 99.59. types are defined in the are changeable. Power control diagram. P.no= Parameters of menu are only visible. Selection of relay output. Out Increase or decrease step of the setpoint. Iftyp.0 is selected, timer runs In.de Out.t. Start by start and relay contact shuts. Adjustable between key 1 and 30. When time is over, relay contact Access code for TYP.2 Stop opens. Iftyp.1 is selected, timer timer configuration menu. A.-.T.c key runs by start. When time is over, NonE= Menu is invisible. relay contact shuts. P.yes= Parameters of menu Indicator are changeable. Selection of buzzer voice type. P.no= Parameters of menu Adjustable 16 different voice types. Sond. are only visible. If this parameter is selected 0, voiced warning is canceled. Power Out Start key TYP.3 Stop key Indicator ETM1411-E-03 2/2

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted