Product Information

AVB 0,35/2/12

AVB 0,35/2/12 electronic component of Block

Datasheet
TRANSFORMER, ISO, 24VAC, 0.35VA

Manufacturer: Block
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 6.6982 ea
Line Total: USD 6.7

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 17 May to Thu. 23 May

MOQ : 1
Multiples : 1
1 : USD 6.6982
25 : USD 6.4789
50 : USD 6.2672
100 : USD 6.1538

     
Manufacturer
Product Category
Power Rating
Isolation Transformer Primary Voltages
Secondary Voltages
Current Rating
Plug Type
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
PT 4.5/2/12 electronic component of Block PT 4.5/2/12

TRANSFORMER, 4.5VA, 2 X 12V
Stock : 0

USTE100/2X115 electronic component of Block USTE100/2X115

Transformer, Isolating 100VA
Stock : 0

STEU500/48 electronic component of Block STEU500/48

TRANSFORMER, 500VA, 230/400V, 2 X 24V
Stock : 0

STEU100/23 electronic component of Block STEU100/23

TRANSFORMER, 100VA, 230/400V, 2 X 115V
Stock : 0

FL24/12 electronic component of Block FL24/12

TRANSFORMER, 24VA, 2 X 12V
Stock : 0

FL14/12 electronic component of Block FL14/12

TRANSFORMER, 14VA, 2 X 12V
Stock : 0

FL24/24 electronic component of Block FL24/24

TRANSFORMER, 24VA, 2 X 24V
Stock : 0

PT 13/2/12 electronic component of Block PT 13/2/12

TRANSFORMER, 13VA, 2 X 12V
Stock : 0

STEU63/23 electronic component of Block STEU63/23

TRANSFORMER, 63VA, 230/400V, 2 X 115V
Stock : 0

PM-0112-070-0 electronic component of Block PM-0112-070-0

POWER SUPPLY, AC-DC, 12V, 7A
Stock : 1

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

PCB Transf Or mers Short circuit proof PCB transformer Short circuit proof PCB transformer AVB AVB Type AVB 0,35/2/.. AVB 0,5/2/.. AVB 1,0/2/.. AVB 1,5/2/.. AVB 2,0/2/.. AVB 2,3/2/.. General Data Input Rated input Voltage 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac Rated input voltage 2 x 115 Vac Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz Rated output voltage 6 - 2 x 24 Vac Output Rated power 0.35 - 3.2 VA Rated output voltage: Order no. 2x6 Vac: AVB 0,35/2/6 2x6 Vac: AVB 0,5/2/6 2x6 Vac: AVB 1,0/2/6 2x6 Vac: AVB 1,5/2/6 2x12 Vac: AVB 2,0/2/12 2x6 Vac: AVB 2,3/2/6 Insulation class B 2x2 Vac: AVB 0,35/2/9 2x8 Vac: AVB 0,5/2/8 2x9 Vac: AVB 1,0/2/9 2x8 Vac: AVB 1,5/2/8 2x8 Vac: AVB 2,3/2/8 2x12 Vac: AVB 0,35/2/12 2x9 Vac: AVB 0,5/2/9 2x12 Vac: AVB 1,0/2/12 2x9 Vac: AVB 1,5/2/9 2x9 Vac: AVB 2,3/2/9 Maximum ambient temperature 70 C 2x15 Vac: AVB 0,35/2/15* 2x12 Vac: AVB 0,5/2/12 2x15 Vac: AVB 1,0/2/15 2x12 Vac: AVB 1,5/2/12 2x12 Vac: AVB 2,3/2/12 2x18 Vac: AVB 0,35/2/18* 2x15 Vac: AVB 0,5/2/15* 2x18 Vac: AVB 1,0/2/18* 2x15 Vac: AVB 1,5/2/15 2x15 Vac: AVB 2,3/2/15 2x24 Vac: AVB 0,35/2/24* 2x18 Vac: AVB 0,5/2/18* 2x24 Vac: AVB 1,0/2/24* 2x18 Vac: AVB 1,5/2/18* 2x18 Vac: AVB 2,3/2/18* Efficiency up to 59 % 2x24 Vac: AVB 0,5/2/24* 2x24 Vac: AVB 1,5/2/24* 2x24 Vac: AVB 2,3/2/24* Degree of protection IP 00 Rated Power 0.35 VA 0.50 VA 1.00 VA 1.50 VA 2.00 VA 2.30 VA No-load voltage (app. x factor) 1.80 1.80 1.32 1.39 1.43 1.43 No-load loss (typ.) 1.30 W 1.10 W 0.90 W 1.00 W 0.90 W 0.90 W Advantages Efficiency 30 % 40 % 55 % 57 % 0 % 59 % Minimum size at high output Standards Unconditionally short-circuit proof Classification Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Double input voltage for series or parallel connection *Mains transformer *Mains transformer *Mains transformer *Mains transformer *Mains transformer Also with double output voltage for series or parallel connection Approvals Designed for high ambient temperatures Approvals cURus cURus cURus cURus cURus cURus Permanent corrosion protection, high insulation value and maximum Environment electrical reliability thanks to XtraDensiFill resin encapsulation Ambient temperature max. 70 C 70 C 70 C 70 C 70 C 70 C Coil shell in 2-chamber technology Safety and protection Self-extinguishing potting and hood material Type encapsulated encapsulated encapsulated encapsulated encapsulated encapsulated Class of Insulation System VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 Applications Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 Safety class (prepared) II II II II II II As a mains transformer for adjustment of the voltage and simple electrical isolation. Short circuit strength inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit proof proof proof proof proof proof As a safety transformer for the safe electrical isolation of the input and output sides. The transformer is suitable for creating SELV and PELV circuits because Order numbers of the limit on the output voltage. Order Number refer to rated output refer to rated output refer to rated output refer to rated output refer to rated output refer to rated output voltage voltage voltage voltage voltage voltage Circuit Diagram Standards & 1 Certifications W Mains transformer UL 5085-1/-2, CSA 22.2 No.66 to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2, CSA 22.2 No.66 Safety isolating transformer to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66 202 subject to change - +PCB Transf Or mers Short circuit proof PCB transformer Short circuit proof PCB transformer AVB AVB Type AVB 0,35/2/.. AVB 0,5/2/.. AVB 1,0/2/.. AVB 1,5/2/.. AVB 2,0/2/.. AVB 2,3/2/.. General Data Input Rated input Voltage 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac 2x115 Vac Rated input voltage 2 x 115 Vac Rated frequency 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz 50 - 60 Hz Rated output voltage 6 - 2 x 24 Vac Output Rated power 0.35 - 3.2 VA Rated output voltage: Order no. 2x6 Vac: AVB 0,35/2/6 2x6 Vac: AVB 0,5/2/6 2x6 Vac: AVB 1,0/2/6 2x6 Vac: AVB 1,5/2/6 2x12 Vac: AVB 2,0/2/12 2x6 Vac: AVB 2,3/2/6 Insulation class B 2x2 Vac: AVB 0,35/2/9 2x8 Vac: AVB 0,5/2/8 2x9 Vac: AVB 1,0/2/9 2x8 Vac: AVB 1,5/2/8 2x8 Vac: AVB 2,3/2/8 2x12 Vac: AVB 0,35/2/12 2x9 Vac: AVB 0,5/2/9 2x12 Vac: AVB 1,0/2/12 2x9 Vac: AVB 1,5/2/9 2x9 Vac: AVB 2,3/2/9 Maximum ambient temperature 70 C 2x15 Vac: AVB 0,35/2/15* 2x12 Vac: AVB 0,5/2/12 2x15 Vac: AVB 1,0/2/15 2x12 Vac: AVB 1,5/2/12 2x12 Vac: AVB 2,3/2/12 2x18 Vac: AVB 0,35/2/18* 2x15 Vac: AVB 0,5/2/15* 2x18 Vac: AVB 1,0/2/18* 2x15 Vac: AVB 1,5/2/15 2x15 Vac: AVB 2,3/2/15 2x24 Vac: AVB 0,35/2/24* 2x18 Vac: AVB 0,5/2/18* 2x24 Vac: AVB 1,0/2/24* 2x18 Vac: AVB 1,5/2/18* 2x18 Vac: AVB 2,3/2/18* Efficiency up to 59 % 2x24 Vac: AVB 0,5/2/24* 2x24 Vac: AVB 1,5/2/24* 2x24 Vac: AVB 2,3/2/24* Degree of protection IP 00 1.1 Rated Power 0.35 VA 0.50 VA 1.00 VA 1.50 VA 2.00 VA 2.30 VA No-load voltage (app. x factor) 1.80 1.80 1.32 1.39 1.43 1.43 No-load loss (typ.) 1.30 W 1.10 W 0.90 W 1.00 W 0.90 W 0.90 W Advantages Efficiency 30 % 40 % 55 % 57 % 0 % 59 % Minimum size at high output Standards Unconditionally short-circuit proof Classification Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Safety isolating transformer Double input voltage for series or parallel connection *Mains transformer *Mains transformer *Mains transformer *Mains transformer *Mains transformer Also with double output voltage for series or parallel connection Approvals Designed for high ambient temperatures Approvals cURus cURus cURus cURus cURus cURus 1.21.2 Permanent corrosion protection, high insulation value and maximum Environment electrical reliability thanks to XtraDensiFill resin encapsulation Ambient temperature max. 70 C 70 C 70 C 70 C 70 C 70 C Coil shell in 2-chamber technology Safety and protection Self-extinguishing potting and hood material Type encapsulated encapsulated encapsulated encapsulated encapsulated encapsulated Class of Insulation System VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 VDE=B, UL=class 105 Applications Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 Safety class (prepared) II II II II II II As a mains transformer for adjustment of the voltage and simple electrical isolation. Short circuit strength inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit inherently short-circuit proof proof proof proof proof proof As a safety transformer for the safe electrical isolation of the input and output 1.3 sides. The transformer is suitable for creating SELV and PELV circuits because Order numbers of the limit on the output voltage. Order Number refer to rated output refer to rated output refer to rated output refer to rated output refer to rated output refer to rated output voltage voltage voltage voltage voltage voltage Circuit Diagram 1.4 Standards & 1 Certifications W 1.5 Mains transformer UL 5085-1/-2, CSA 22.2 No.66 to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL 5085-1/-2, CSA 22.2 No.66 Safety isolating transformer to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6, UL 5085-1/-2, CSA 22.2 No.66 subject to change 203 - +

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted