ZY1207 7A No-Bus POL Data Sheet 3V to 14V Input 0.5V to 5.5V Output Member of the Family Features RoHS lead free and lead-solder-exempt products are available Wide input voltage range: 3V14V High continuous output current: 7A Wide programmable output voltage range: 0.5V5.5V Active digital current share Output voltage margining Overcurrent and overtemperature protections Overvoltage and undervoltage protections, and Power Applications Good signal tracking the output voltage setpoint Low voltage, high density systems with Programmable power-up delay Intermediate Bus Architectures (IBA) Tracking during turn-on and turn-off with guaranteed Point-of-load regulators for high performance DSP, slew rates FPGA, ASIC, and microprocessor applications Sequenced and cascaded modes of operation Desktops, servers, and portable computing Single-wire line for frequency synchronization Broadband, networking, optical, and between multiple POLs communications systems Programmable interleave Active memory bus terminators Programmable feedback loop compensation Enable control with programmable polarity Benefits Flexible fault management and propagation Integrates digital power conversion with intelligent Start-up into the load pre-biased up to 100% power management Full rated current sink Eliminates the need for external power Real time current and temperature measurements, management components and communication bus monitoring, and reporting Completely programmable via pin strapping and Small footprint SMT package: 12.5x22mm external R and C Low profile of 6.5mm One part that covers all applications Compatible with conventional pick-and-place Reduces board space, system cost and equipment complexity, and time to market Wide industrial operating temperature range UL 60950-1/CSA 22.2 No. 60950-1-07 Second Edition, IEC 60950-1: 2005, and EN 60950-1:2006 Description Power-Ones point-of-load converters are recommended for use with regulated bus converters in an Intermediate Bus Architecture (IBA). The ZY1207 is an intelligent, fully programmable step-down point-of-load DC-DC module integrating digital power conversion and intelligent power management. The ZY1207 completely eliminates the need for external components for sequencing, tracking, protection, monitoring, and reporting. Performance parameters of the ZY1207 are programmable by pin strapping and external resistor and capacitor and can be changed by a user at any time during product development and service without a need for a communication bus. ZD-00697 Rev. 2.1, 11-Oct-2011 www.power-one.com Page 1 of 18 ZY1207 7A No-Bus POL Data Sheet 3V to 14V Input 0.5V to 5.5V Output Reference Documents TM No-Bus POL Converters. Z-1000 Series Application Note Z-One POL Converters. Eutectic Solder Process Application Note Z-One POL Converters. Lead-Free Process Application Note 1. Ordering Information ZY 12 07 x y zz 3 Product Series: Output Output voltage setpoint RoHS compliance: Dash Packaging Option : family: Current: accuracy: No suffix - RoHS T1 500pcs T&R No-Bus Z-One POL 7A No suffix 1.5% or 35mV, compliant with Pb T2 100pcs T&R 2 Module Converter whichever is greater. solder exemption T3 50pcs T&R 1 H 1.5% or 20mV, G - RoHS compliant Q1 1pc sample for whichever is greater for all six substances evaluation only K1 1pc mounted on 4 the evaluation board 1 Contact factory for availability. 2 The solder exemption refers to all the restricted materials except lead in solder. These materials are Cadmium (Cd), Hexavalent chromium (Cr6+), Mercury (Hg), Polybrominated biphenyls (PBB), Polybrominated diphenylethers (PBDE), and Lead (Pb) used anywhere except in solder. 3 Packaging option is used only for ordering and not included in the part number printed on the POL converter label. 4 The evaluation board is available in only one configuration: ZY1207-K1. Example: ZY1207HG-T2: A 100-peices reel of RoHS compliant POL converters with the output voltage setpoint of 1.5% or 20mV, whichever is greater. Each POL converter is labeled ZY1207HG. 2. Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely affect long- term reliability, and cause permanent damage to the POL converter. Parameter Conditions/Description Min Max Units Operating Temperature Controller Case Temperature -40 105 C Input Voltage 250ms Transient 15 VDC Output Current (See Output Current Derating Curves) -7 7 ADC 3. Environmental and Mechanical Specifications Parameter Conditions/Description Min Nom Max Units Ambient Temperature Range -40 85 C Storage Temperature (Ts) -55 125 C Weight 8 grams MTBF Calculated Per Telcordia Technologies SR-332 6.24 MHrs ZY1207 220 C Peak Reflow Temperature ZY1207G 245 260 C 100% Matte Tin or Lead Plating ZY1207 and ZY1207G 1.5m Ag over 1.5m Ni ZY1207 2 Moisture Sensitivity Level ZY1207G 3 ZD-00697 Rev. 2.1, 11-Oct-2011 www.power-one.com Page 2 of 18